A deep learning-based whole-body solution for PET/MRI attenuation correction

被引:8
|
作者
Ahangari, Sahar [1 ,2 ]
Olin, Anders Beck [1 ,2 ]
Federspiel, Marianne Kinggard [1 ,2 ]
Jakoby, Bjoern [3 ]
Andersen, Thomas Lund [1 ,2 ]
Hansen, Adam Espe [1 ,2 ,4 ,5 ]
Fischer, Barbara Malene [1 ,2 ,4 ]
Andersen, Flemming Littrup [1 ,2 ,4 ]
机构
[1] Rigshosp, Dept Clin Physiol, Nucl Med, Copenhagen, Denmark
[2] Rigshosp, PET, Copenhagen, Denmark
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
[5] Rigshosp, Dept Diagnost Radiol, Copenhagen, Denmark
基金
欧盟地平线“2020”;
关键词
PET; MRI; MR-AC; Attenuation correction; Deep learning; Whole body; QUANTITATIVE-EVALUATION; MRI; TRUNCATION;
D O I
10.1186/s40658-022-00486-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. Materials and methods Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. Results Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R-2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. Conclusions Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [22] Influence of Bones and Constant Attenuation Factors in PET/CT: Learning for MR-based Attenuation Correction in Whole-Body MR/PET
    Martinez-Moeller, A.
    Souvatzoglou, M.
    Bundschuh, R. A.
    Delso, G.
    Ziegler, S. I.
    Navab, N.
    Schwaiger, M.
    Nekolla, S. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S193 - S194
  • [23] Adaptive, segmented attenuation correction for whole-body PET imaging
    Xu, M
    Cutler, PD
    Luk, WK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) : 331 - 336
  • [24] Description and assessment of a registration-based approach to include bones for attenuation correction of whole-body PET/MRI
    Marshall, Harry R.
    Patrick, John
    Laidley, David
    Prato, Frank S.
    Butler, John
    Theberge, Jean
    Thompson, R. Terry
    Stodilka, Robert Z.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [25] MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods
    Hofmann, Matthias
    Bezrukov, Ilja
    Mantlik, Frederic
    Aschoff, Philip
    Steinke, Florian
    Beyer, Thomas
    Pichler, Bernd J.
    Schoelkopf, Bernhard
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (09) : 1392 - 1399
  • [26] Deep learning-based attenuation correction for brain PET with various radiotracers
    Fumio Hashimoto
    Masanori Ito
    Kibo Ote
    Takashi Isobe
    Hiroyuki Okada
    Yasuomi Ouchi
    Annals of Nuclear Medicine, 2021, 35 : 691 - 701
  • [27] Deep learning-based attenuation correction for brain PET with various radiotracers
    Hashimoto, Fumio
    Ito, Masanori
    Ote, Kibo
    Isobe, Takashi
    Okada, Hiroyuki
    Ouchi, Yasuomi
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (06) : 691 - 701
  • [28] Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data
    Martinez-Moeller, Axel
    Souvatzoglou, Michael
    Delso, Gaspar
    Bundschuh, Ralph A.
    Chefd'hotel, Christophe
    Ziegler, Sibylle I.
    Navab, Nassir
    Schwaiger, Markus
    Nekolla, Stephan G.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) : 520 - 526
  • [29] MR-based Attenuation Correction for a Whole-body Sequential PET/MR System
    Hu, Z.
    Ojha, N.
    Renisch, S.
    Schulz, V.
    Torres, I.
    Buhl, A.
    Pal, D.
    Muswick, G.
    Penatzer, J.
    Guo, T.
    Boenert, P.
    Tung, C.
    Kaste, J.
    Morich, M.
    Havens, T.
    Maniawski, P.
    Schaefer, W.
    Guenther, R. W.
    Krombach, G. A.
    Shao, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3508 - 3512
  • [30] Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Baumann, Bettina Beuthien
    Platzek, Ivan
    Kotzerke, Jorg
    Steinbach, Joerg
    van den Hoff, Joerg
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53