Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction

被引:52
|
作者
Schramm, Georg [1 ]
Langner, Jens [1 ]
Hofheinz, Frank [1 ]
Petr, Jan [1 ]
Beuthien-Baumann, Bettina [2 ]
Platzek, Ivan [3 ]
Steinbach, Joerg [1 ]
Kotzerke, Joerg [2 ]
van den Hoff, Joerg [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, PET Ctr, Inst Radiopharm, Dresden, Germany
[2] Tech Univ Dresden, Dept Nucl Med, Univ Hosp Carl Gustav Carus, D-01062 Dresden, Germany
[3] Tech Univ Dresden, Dept Radiol, Univ Hosp Carl Gustav Carus, D-01062 Dresden, Germany
关键词
PET/MR; MR-based attenuation correction; PET quantification; PERFORMANCE EVALUATION; NEXT-GENERATION; MRI; IMAGES; CT;
D O I
10.1007/s10334-012-0328-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Evaluation of the quantitative accuracy of MR-based attenuation correction (MRAC) in the Philips Ingenuity TF whole-body PET/MR. In 13 patients, PET emission data from the PET/MR were reconstructed using two different methods for attenuation correction. In the first reconstruction, the vendor-provided standard MRAC was used. In the second reconstruction, a coregistered transmission-based attenuation map from a second immediately preceding investigation with a stand-alone Siemens ECAT EXACT HR+ PET scanner was used (TRAC). The two attenuation maps were compared regarding occurrence of segmentation artifacts in the MRAC procedure. Standard uptake values (SUVs) of multiple VOIs (liver, cerebellum, hot focal structures at various locations in the trunk) were compared between both reconstructed data sets. Furthermore, a voxel-wise intensity correlation analysis of both data sets in the lung and trunk was performed. VOI averaged SUV differences between MRAC and TRAC were as follows (relative differences, mean +/- A standard deviation): (+12 +/- A 6) % cerebellum, (-4 +/- A 9) % liver, (-2 +/- A 11) % hot focal structures. The fitted slopes of the voxel-wise correlations in the lung and trunk were 0.87 +/- A 0.17 and 0.95 +/- A 0.10 with averaged adjusted R (2) values of 0.96 and 0.98, respectively. These figures include two instances with partially erroneous lung segmentation due to artifacts in the underlying MR images. The MR-based attenuation correction implemented on the Philips Ingenuity PET/MR provides reasonable quantitative accuracy. On average, deviations from TRAC-based results are small (on the order of 10 % or below) across the trunk, but due to interindividual variability of the segmentation quality, deviations of more than 20 % can occur. Future improvement of the segmentation quality would help to increase the quantitation accuracy further and to reduce the inter-subject variability.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 50 条
  • [31] Adaptive, segmented attenuation correction for whole-body PET imaging
    Xu, M
    Cutler, PD
    Luk, WK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (01) : 331 - 336
  • [32] Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR
    Oehmigen, Mark
    Lindemann, Maike E.
    Gratz, Marcel
    Kirchner, Julian
    Ruhlmann, Verena
    Umutlu, Lale
    Blumhagen, Jan Ole
    Fenchel, Matthias
    Quick, Harald H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (04) : 642 - 653
  • [33] Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR
    Mark Oehmigen
    Maike E. Lindemann
    Marcel Gratz
    Julian Kirchner
    Verena Ruhlmann
    Lale Umutlu
    Jan Ole Blumhagen
    Matthias Fenchel
    Harald H. Quick
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 642 - 653
  • [34] Whole-Body PET/MR Imaging: Quantitative Evaluation of a Novel Model-Based MR Attenuation Correction Method Including Bone
    Paulus, Daniel H.
    Quick, Harald H.
    Geppert, Christian
    Fenchel, Matthias
    Zhan, Yiqiang
    Hermosillo, Gerardo
    Faul, David
    Boada, Fernando
    Friedman, Kent P.
    Koesters, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (07) : 1061 - 1066
  • [35] Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI
    Keller, Sune H.
    Holm, Soren
    Hansen, Adam E.
    Sattler, Bernhard
    Andersen, Flemming
    Klausen, Thomas L.
    Hojgaard, Liselotte
    Kjaer, Andreas
    Beyer, Thomas
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (01) : 173 - 181
  • [36] Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI
    Sune H. Keller
    Søren Holm
    Adam E. Hansen
    Bernhard Sattler
    Flemming Andersen
    Thomas L. Klausen
    Liselotte Højgaard
    Andreas Kjær
    Thomas Beyer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 173 - 181
  • [37] The impact of MR-guided PET attenuation correction on whole-body dynamic and parametric PET imaging
    Karakatsanis, Nicolas
    Tsoumpas, Charalampos
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [38] Evaluation and automatic correction of metal-implant-induced artifacts in MR-based attenuation correction in whole-body PET/MR imaging
    Schramm, G.
    Maus, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2713 - 2726
  • [39] Comparison of 4-Class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation Correction
    Wollenweber, S. D.
    Ambwani, S.
    Lonn, A. H. R.
    Shanbhag, D. D.
    Thiruvenkadam, S.
    Kaushik, S.
    Mullick, R.
    Qian, H.
    Delso, G.
    Wiesinger, F.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3391 - 3398
  • [40] Comparison of 4-class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation Correction
    Wollenweber, S. D.
    Ambwani, S.
    Lonn, A. H. R.
    Shanbhag, D. D.
    Thiruvenkadam, S.
    Kaushik, S.
    Mullick, R.
    Wiesinger, F.
    Qian, H.
    Delso, G.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3019 - 3025