Comparison of 4-Class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation Correction

被引:71
|
作者
Wollenweber, S. D. [1 ]
Ambwani, S. [1 ]
Lonn, A. H. R. [2 ]
Shanbhag, D. D. [3 ]
Thiruvenkadam, S. [3 ]
Kaushik, S. [3 ]
Mullick, R. [3 ]
Qian, H. [4 ]
Delso, G. [5 ,6 ]
Wiesinger, F. [7 ]
机构
[1] GE Healthcare, Waukesha, WI 53005 USA
[2] GE Healthcare, Chalfont St Giles HP8 4SP, Bucks, England
[3] GE Global Res, Bangalore 560066, Karnataka, India
[4] GE Global Res, Niskayuna, NY 12309 USA
[5] GE Healthcare, CH-8006 Zurich, Switzerland
[6] Univ Zurich Hosp, CH-8006 Zurich, Switzerland
[7] GE Global Res, D-80331 Munich, Germany
关键词
Image analysis; magnetic resonance imaging; positron emission tomography; reconstruction algorithms; CLASSIFICATION; FAT;
D O I
10.1109/TNS.2013.2278759
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The goal of this study was to compare two approaches for MR-based PET patient attenuation correction (AC) in whole-body FDG-PET imaging using a tri-modality PET/CT and MR setup. Sixteen clinical whole-body FDG patients were included in this study. Mean standard uptake values (SUVs) were measured for liver and lung volumes-of-interest for comparison. Maximum SUVs were measured in 18 FDG-avid features in 10 of the patients. The AC methods compared to gold-standard CT-based AC were segmentation of the CT (air, lung, fat, water), MR image segmentation with four tissue classes (air, lung, fat, water), and segmentation with air, lung and a continuous fat/water method. Results show that magnitude differences of the uptake values induced by CT-based image segmentation were similar but lower on average than those found using MR-derived AC methods. The average liver SUV difference as compared to using CTAC was 1.3%, 10.4%, and 5.7% for 4-class segmented CT, 4-class MRAC, and continuous fat/water MRAC methods, respectively. The average FDG-avid feature SUVmax difference was -0.5%, 1.7%, and -1.6% for 4-class segmented CT, 4-classMRAC, and continuous fat/water MRAC methods, respectively. The results demonstrated that both 4-class and continuous fat/water AC methods provided adequate quantitation in the body, and that the continuous fat/watermethod was within 5.7% on average for SUVmean in liver and 1.6% on average for SUVmax for FDG-avid features.
引用
收藏
页码:3391 / 3398
页数:8
相关论文
共 50 条
  • [1] Comparison of 4-class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation Correction
    Wollenweber, S. D.
    Ambwani, S.
    Lonn, A. H. R.
    Shanbhag, D. D.
    Thiruvenkadam, S.
    Kaushik, S.
    Mullick, R.
    Wiesinger, F.
    Qian, H.
    Delso, G.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3019 - 3025
  • [2] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [3] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    Brady, Thomas
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [5] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [6] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [7] Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Baumann, Bettina Beuthien
    Platzek, Ivan
    Kotzerke, Jorg
    Steinbach, Joerg
    van den Hoff, Joerg
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [8] MR-based Attenuation Correction for a Whole-body Sequential PET/MR System
    Hu, Z.
    Ojha, N.
    Renisch, S.
    Schulz, V.
    Torres, I.
    Buhl, A.
    Pal, D.
    Muswick, G.
    Penatzer, J.
    Guo, T.
    Boenert, P.
    Tung, C.
    Kaste, J.
    Morich, M.
    Havens, T.
    Maniawski, P.
    Schaefer, W.
    Guenther, R. W.
    Krombach, G. A.
    Shao, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3508 - 3512
  • [9] Whole-body MR-based attenuation correction for PET using UTE Sequences
    Keereman, V.
    Fierens, Y.
    De Deene, Y.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S220 - S220
  • [10] Influence of Bones and Constant Attenuation Factors in PET/CT: Learning for MR-based Attenuation Correction in Whole-Body MR/PET
    Martinez-Moeller, A.
    Souvatzoglou, M.
    Bundschuh, R. A.
    Delso, G.
    Ziegler, S. I.
    Navab, N.
    Schwaiger, M.
    Nekolla, S. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S193 - S194