Comparison of 4-Class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation Correction

被引:71
|
作者
Wollenweber, S. D. [1 ]
Ambwani, S. [1 ]
Lonn, A. H. R. [2 ]
Shanbhag, D. D. [3 ]
Thiruvenkadam, S. [3 ]
Kaushik, S. [3 ]
Mullick, R. [3 ]
Qian, H. [4 ]
Delso, G. [5 ,6 ]
Wiesinger, F. [7 ]
机构
[1] GE Healthcare, Waukesha, WI 53005 USA
[2] GE Healthcare, Chalfont St Giles HP8 4SP, Bucks, England
[3] GE Global Res, Bangalore 560066, Karnataka, India
[4] GE Global Res, Niskayuna, NY 12309 USA
[5] GE Healthcare, CH-8006 Zurich, Switzerland
[6] Univ Zurich Hosp, CH-8006 Zurich, Switzerland
[7] GE Global Res, D-80331 Munich, Germany
关键词
Image analysis; magnetic resonance imaging; positron emission tomography; reconstruction algorithms; CLASSIFICATION; FAT;
D O I
10.1109/TNS.2013.2278759
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The goal of this study was to compare two approaches for MR-based PET patient attenuation correction (AC) in whole-body FDG-PET imaging using a tri-modality PET/CT and MR setup. Sixteen clinical whole-body FDG patients were included in this study. Mean standard uptake values (SUVs) were measured for liver and lung volumes-of-interest for comparison. Maximum SUVs were measured in 18 FDG-avid features in 10 of the patients. The AC methods compared to gold-standard CT-based AC were segmentation of the CT (air, lung, fat, water), MR image segmentation with four tissue classes (air, lung, fat, water), and segmentation with air, lung and a continuous fat/water method. Results show that magnitude differences of the uptake values induced by CT-based image segmentation were similar but lower on average than those found using MR-derived AC methods. The average liver SUV difference as compared to using CTAC was 1.3%, 10.4%, and 5.7% for 4-class segmented CT, 4-class MRAC, and continuous fat/water MRAC methods, respectively. The average FDG-avid feature SUVmax difference was -0.5%, 1.7%, and -1.6% for 4-class segmented CT, 4-classMRAC, and continuous fat/water MRAC methods, respectively. The results demonstrated that both 4-class and continuous fat/water AC methods provided adequate quantitation in the body, and that the continuous fat/watermethod was within 5.7% on average for SUVmean in liver and 1.6% on average for SUVmax for FDG-avid features.
引用
收藏
页码:3391 / 3398
页数:8
相关论文
共 50 条
  • [21] A comparison of MR-based attenuation correction in PET versus SPECT
    Marshall, H. R.
    Stodilka, R. Z.
    Theberge, J.
    Sabondjian, E.
    Legros, A.
    Deans, L.
    Sykes, J. M.
    Thompson, R. T.
    Prato, F. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14): : 4613 - 4629
  • [22] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [23] Accuracy and reproducibility of standard MR-based attenuation maps of the thorax: An inter-system comparison of whole-body PET/MR systems
    Lassen, M. L.
    Quick, H.
    Boellaard, R.
    Delso, G.
    Rausch, I.
    Sattler, B.
    Yaqub, M.
    Ziegler, S.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S408 - S408
  • [24] Clinical Assessment of MR-Guided 3-Class and 4-Class Attenuation Correction in PET/MR
    Arabi, Hossein
    Rager, Olivier
    Alem, Asma
    Varoquaux, Arthur
    Becker, Minerva
    Zaidi, Habib
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (02) : 264 - 276
  • [25] Clinical Assessment of MR-Guided 3-Class and 4-Class Attenuation Correction in PET/MR
    Hossein Arabi
    Olivier Rager
    Asma Alem
    Arthur Varoquaux
    Minerva Becker
    Habib Zaidi
    Molecular Imaging and Biology, 2015, 17 : 264 - 276
  • [26] A comparison of CT- and MR-based attenuation correction in neurological PET
    John C. Dickson
    Celia O’Meara
    Anna Barnes
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1176 - 1189
  • [27] A comparison of CT- and MR-based attenuation correction in neurological PET
    Dickson, John C.
    O'Meara, Celia
    Barnes, Anna
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (06) : 1176 - 1189
  • [28] Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner
    Bini, Jason
    Izquierdo-Garcia, David
    Mateo, Jesus
    Machac, Josef
    Narula, Jagat
    Fuster, Valentin
    Fayad, Zahi A.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (05) : 313 - 322
  • [29] Optimization Of MR-Based Attenuation Correction For Cardiac PET/MR
    Vergani, V.
    Robson, P.
    Trivieri, M.
    Fayad, Z. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S699 - S700
  • [30] Potential influence of Gadolinium contrast on image segmentation in MR-based attenuation correction with Dixon sequences in whole-body 18F-FDG PET/MR
    Verena Ruhlmann
    Philipp Heusch
    Hilmar Kühl
    Karsten Beiderwellen
    Gerald Antoch
    Michael Forsting
    Andreas Bockisch
    Christian Buchbender
    Harald H. Quick
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 301 - 308