Comparison of 4-Class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation Correction

被引:71
|
作者
Wollenweber, S. D. [1 ]
Ambwani, S. [1 ]
Lonn, A. H. R. [2 ]
Shanbhag, D. D. [3 ]
Thiruvenkadam, S. [3 ]
Kaushik, S. [3 ]
Mullick, R. [3 ]
Qian, H. [4 ]
Delso, G. [5 ,6 ]
Wiesinger, F. [7 ]
机构
[1] GE Healthcare, Waukesha, WI 53005 USA
[2] GE Healthcare, Chalfont St Giles HP8 4SP, Bucks, England
[3] GE Global Res, Bangalore 560066, Karnataka, India
[4] GE Global Res, Niskayuna, NY 12309 USA
[5] GE Healthcare, CH-8006 Zurich, Switzerland
[6] Univ Zurich Hosp, CH-8006 Zurich, Switzerland
[7] GE Global Res, D-80331 Munich, Germany
关键词
Image analysis; magnetic resonance imaging; positron emission tomography; reconstruction algorithms; CLASSIFICATION; FAT;
D O I
10.1109/TNS.2013.2278759
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The goal of this study was to compare two approaches for MR-based PET patient attenuation correction (AC) in whole-body FDG-PET imaging using a tri-modality PET/CT and MR setup. Sixteen clinical whole-body FDG patients were included in this study. Mean standard uptake values (SUVs) were measured for liver and lung volumes-of-interest for comparison. Maximum SUVs were measured in 18 FDG-avid features in 10 of the patients. The AC methods compared to gold-standard CT-based AC were segmentation of the CT (air, lung, fat, water), MR image segmentation with four tissue classes (air, lung, fat, water), and segmentation with air, lung and a continuous fat/water method. Results show that magnitude differences of the uptake values induced by CT-based image segmentation were similar but lower on average than those found using MR-derived AC methods. The average liver SUV difference as compared to using CTAC was 1.3%, 10.4%, and 5.7% for 4-class segmented CT, 4-class MRAC, and continuous fat/water MRAC methods, respectively. The average FDG-avid feature SUVmax difference was -0.5%, 1.7%, and -1.6% for 4-class segmented CT, 4-classMRAC, and continuous fat/water MRAC methods, respectively. The results demonstrated that both 4-class and continuous fat/water AC methods provided adequate quantitation in the body, and that the continuous fat/watermethod was within 5.7% on average for SUVmean in liver and 1.6% on average for SUVmax for FDG-avid features.
引用
收藏
页码:3391 / 3398
页数:8
相关论文
共 50 条
  • [11] Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    Schulz, V.
    Torres-Espallardo, I.
    Renisch, S.
    Hu, Z.
    Ojha, N.
    Boernert, P.
    Perkuhn, M.
    Niendorf, T.
    Schaefer, W. M.
    Brockmann, H.
    Krohn, T.
    Buhl, A.
    Guenther, R. W.
    Mottaghy, F. M.
    Krombach, G. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (01) : 138 - 152
  • [12] Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    V. Schulz
    I. Torres-Espallardo
    S. Renisch
    Z. Hu
    N. Ojha
    P. Börnert
    M. Perkuhn
    T. Niendorf
    W. M. Schäfer
    H. Brockmann
    T. Krohn
    A. Buhl
    R. W. Günther
    F. M. Mottaghy
    G. A. Krombach
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 138 - 152
  • [13] Validation of MR-Based Attenuation Correction of a Newly Released Whole-Body Simultaneous PET/MR System
    Liu, Guobing
    Cao, Tuoyu
    Hu, Lingzhi
    Zheng, Jiaxu
    Pang, Lifang
    Hu, Pengcheng
    Gu, Yushen
    Shi, Hongcheng
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [14] Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI
    Keller, Sune H.
    Holm, Soren
    Hansen, Adam E.
    Sattler, Bernhard
    Andersen, Flemming
    Klausen, Thomas L.
    Hojgaard, Liselotte
    Kjaer, Andreas
    Beyer, Thomas
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2013, 26 (01) : 173 - 181
  • [15] Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI
    Sune H. Keller
    Søren Holm
    Adam E. Hansen
    Bernhard Sattler
    Flemming Andersen
    Thomas L. Klausen
    Liselotte Højgaard
    Andreas Kjær
    Thomas Beyer
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 173 - 181
  • [16] Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging
    Aznar, M. C.
    Sersar, R.
    Saabye, J.
    Ladefoged, C. N.
    Andersen, F. L.
    Rasmussen, J. H.
    Lofgren, J.
    Beyer, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1177 - 1183
  • [17] MR-based attenuation correction limits accuracy of quality control experiments on whole-body PET/MR systems
    Boellaard, R.
    Rausch, I.
    Beyer, T.
    Delso, G.
    Ziegler, S.
    Yaqub, M.
    Quick, H.
    Sattler, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S254 - S254
  • [18] Evaluation and automatic correction of metal-implant-induced artifacts in MR-based attenuation correction in whole-body PET/MR imaging
    Schramm, G.
    Maus, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2713 - 2726
  • [19] Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction
    Attenberger, Ulrike
    Catana, Ciprian
    Chandarana, Hersh
    Catalano, Onofrio A.
    Friedman, Kent
    Schonberg, Stefan A.
    Thrall, James
    Salvatore, Marco
    Rosen, Bruce R.
    Guimaraes, Alexander R.
    ABDOMINAL IMAGING, 2015, 40 (06): : 1374 - 1386
  • [20] Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction
    Ulrike Attenberger
    Ciprian Catana
    Hersh Chandarana
    Onofrio A Catalano
    Kent Friedman
    Stefan A Schonberg
    James Thrall
    Marco Salvatore
    Bruce R. Rosen
    Alexander R. Guimaraes
    Abdominal Imaging, 2015, 40 : 1374 - 1386