Diagnostic accuracy of 13N-ammonia myocardial perfusion imaging with PET-CT in the detection of coronary artery disease
被引:16
|
作者:
Fathala, Ahmed
论文数: 0引用数: 0
h-index: 0
机构:
King Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi ArabiaKing Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
Fathala, Ahmed
[1
]
Aboulkheir, Mervat
论文数: 0引用数: 0
h-index: 0
机构:
King Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
Taibah Univ, Madinah, Saudi ArabiaKing Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
Aboulkheir, Mervat
[1
,2
]
Shoukri, Mohamamed M.
论文数: 0引用数: 0
h-index: 0
机构:
King Faisal Specialist Hosp & Res Ctr, Dept Cell Biol, Riyadh, Saudi ArabiaKing Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
Shoukri, Mohamamed M.
[3
]
Alsergani, Hani
论文数: 0引用数: 0
h-index: 0
机构:
King Faisal Specialist Hosp & Res Ctr, King Faisal Heart Inst, Riyadh, Saudi ArabiaKing Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
Alsergani, Hani
[4
]
机构:
[1] King Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
[2] Taibah Univ, Madinah, Saudi Arabia
[3] King Faisal Specialist Hosp & Res Ctr, Dept Cell Biol, Riyadh, Saudi Arabia
[4] King Faisal Specialist Hosp & Res Ctr, King Faisal Heart Inst, Riyadh, Saudi Arabia
Background: N-13-ammonia positron emission tomography-computed tomography (PET-CT) is being increasingly used as a non-invasive imaging modality for evaluating patients with known or suspected coronary artery disease (CAD), but information about the diagnostic accuracy of PET-MPI is sparse. Objectives: Our objective was to determine the accuracy of N-13-ammonia PET-CT myocardial perfusion imaging (MPI) for detecting CAD. Methods: We retrospectively evaluated 383 patients with suspected CAD who underwent rest-stress (13)-Nammonia PET-CT MPI. Invasive coronary angiography (ICA) was performed within 60 days for all patients with abnormal PET-MPI findings and for selected patients with normal PET-MPI findings. Results: The mean age of the patients was 64 +/- 11 years, and the mean body mass index was 32 +/- 7 kg/m(2). Stress perfusion defects were identified in 147 (34%) out of a total of 383 patients. ICA was performed in 213 patients (145 patients with abnormal PET and 68 patients with normal PET). The sensitivity of PET-MPI for detection of obstructive CAD based on >= 50% stenosis was 90%; specificity, 90%; positive predictive value, 96%; negative predictive value, 76%; and diagnostic accuracy, 80%. Conclusions: PET-MPI with N-13-ammonia affords high sensitivity and overall accuracy for detecting CAD. The addition of coronary artery calcium score (CACS) can improve CAD risk stratification.
机构:
INVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USAINVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USA
Renaud, Jennifer M.
Poitrasson-Riviere, Alexis
论文数: 0引用数: 0
h-index: 0
机构:
INVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USAINVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USA
Poitrasson-Riviere, Alexis
Moody, Jonathan B.
论文数: 0引用数: 0
h-index: 0
机构:
INVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USAINVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USA
Moody, Jonathan B.
Hagio, Tomoe
论文数: 0引用数: 0
h-index: 0
机构:
INVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USAINVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USA
Hagio, Tomoe
Ficaro, Edward P.
论文数: 0引用数: 0
h-index: 0
机构:
INVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USAINVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USA
Ficaro, Edward P.
Murthy, Venkatesh L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Internal Med, Div Cardiovasc Med, Ann Arbor, MI USAINVIA Med Imaging Solut, 3025 Boardwalk Dr,Suite 200, Ann Arbor, MI 48108 USA
机构:
Univ Med Ctr Groningen, NL-9713 AV Groningen, NetherlandsUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Monroy-Gonzalez, A.
Juarez-Orozco, L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Med Ctr Groningen, NL-9713 AV Groningen, NetherlandsUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Juarez-Orozco, L.
Berrios-Barcenas, E.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Nacl Cardiol Ignacio Chavez, Mexico City, DF, MexicoUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Berrios-Barcenas, E.
Flores-Gonzalez, E.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Nacl Cardiol Ignacio Chavez, Mexico City, DF, MexicoUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Flores-Gonzalez, E.
Cruz-Mendoza, R.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Nacl Cardiol Ignacio Chavez, Mexico City, DF, MexicoUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Cruz-Mendoza, R.
Tio, R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Med Ctr Groningen, NL-9713 AV Groningen, NetherlandsUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Tio, R.
论文数: 引用数:
h-index:
机构:
Slart, R.
Dierckx, R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Med Ctr Groningen, NL-9713 AV Groningen, NetherlandsUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands
Dierckx, R.
Alexanderson, E.
论文数: 0引用数: 0
h-index: 0
机构:
Inst Nacl Cardiol Ignacio Chavez, Mexico City, DF, Mexico
Unidad PET CT UNAM, Mexico City, DF, MexicoUniv Med Ctr Groningen, NL-9713 AV Groningen, Netherlands