Diagnostic accuracy of 13N-ammonia myocardial perfusion imaging with PET-CT in the detection of coronary artery disease

被引:16
|
作者
Fathala, Ahmed [1 ]
Aboulkheir, Mervat [1 ,2 ]
Shoukri, Mohamamed M. [3 ]
Alsergani, Hani [4 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
[2] Taibah Univ, Madinah, Saudi Arabia
[3] King Faisal Specialist Hosp & Res Ctr, Dept Cell Biol, Riyadh, Saudi Arabia
[4] King Faisal Specialist Hosp & Res Ctr, King Faisal Heart Inst, Riyadh, Saudi Arabia
关键词
Positron emission tomography-computed tomography myocardial perfusion imaging (PETCT MPI); N-13-ammonia positron emission tomography-computed tomography myocardial perfusion (N-13-ammonia PET-CT myocardial perfusion); coronary artery calcium score (CACS); POSITRON-EMISSION-TOMOGRAPHY; DIPYRIDAMOLE STRESS; COMPUTED-TOMOGRAPHY; PROGNOSTIC VALUE; CALCIUM SCORE; RISK-FACTORS; QUANTIFICATION;
D O I
10.21037/cdt.2018.10.12
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: N-13-ammonia positron emission tomography-computed tomography (PET-CT) is being increasingly used as a non-invasive imaging modality for evaluating patients with known or suspected coronary artery disease (CAD), but information about the diagnostic accuracy of PET-MPI is sparse. Objectives: Our objective was to determine the accuracy of N-13-ammonia PET-CT myocardial perfusion imaging (MPI) for detecting CAD. Methods: We retrospectively evaluated 383 patients with suspected CAD who underwent rest-stress (13)-Nammonia PET-CT MPI. Invasive coronary angiography (ICA) was performed within 60 days for all patients with abnormal PET-MPI findings and for selected patients with normal PET-MPI findings. Results: The mean age of the patients was 64 +/- 11 years, and the mean body mass index was 32 +/- 7 kg/m(2). Stress perfusion defects were identified in 147 (34%) out of a total of 383 patients. ICA was performed in 213 patients (145 patients with abnormal PET and 68 patients with normal PET). The sensitivity of PET-MPI for detection of obstructive CAD based on >= 50% stenosis was 90%; specificity, 90%; positive predictive value, 96%; negative predictive value, 76%; and diagnostic accuracy, 80%. Conclusions: PET-MPI with N-13-ammonia affords high sensitivity and overall accuracy for detecting CAD. The addition of coronary artery calcium score (CACS) can improve CAD risk stratification.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 50 条
  • [11] Incidental extra-cardiac findings on 13N-ammonia myocardial perfusion PET/CT
    Kan, H.
    Zant, F. M. van der
    Wondergem, M.
    Knol, R. J. J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (06) : 1860 - 1868
  • [12] A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET
    Golish, SR
    Hove, JD
    Schelbert, HR
    Gambhir, SS
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (06) : 924 - 931
  • [13] Myocardial bridging of the left anterior descending coronary artery is associated with reduced myocardial perfusion reserve: a 13N-ammonia PET study
    Monroy-Gonzalez, Andrea G.
    Alexanderson-Rosas, Erick
    Prakken, Niek H. J.
    Juarez-Orozco, Luis E.
    Walls-Laguarda, Lourdes
    Berrios-Barcenas, Enrique A.
    Meave-Gonzalez, Aloha
    Groot, Jan C.
    Slart, Riemer H. J. A.
    Tio, Rene A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (02): : 375 - 382
  • [14] Myocardial bridging of the left anterior descending coronary artery is associated with reduced myocardial perfusion reserve: a 13N-ammonia PET study
    Andrea G. Monroy-Gonzalez
    Erick Alexanderson-Rosas
    Niek H. J. Prakken
    Luis E. Juarez-Orozco
    Lourdes Walls-Laguarda
    Enrique A. Berrios-Barcenas
    Aloha Meave-Gonzalez
    Jan C. Groot
    Riemer H. J. A. Slart
    Rene A. Tio
    The International Journal of Cardiovascular Imaging, 2019, 35 : 375 - 382
  • [15] Evaluation of perfusion and image quality changes by reconstruction methods in 13N-ammonia myocardial perfusion PET/CT
    Do, Yong Ho
    Lee, Hong Jae
    Kim, Jin Eui
    Im, Hyung Jun
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [16] Evaluation of perfusion and image quality changes by reconstruction methods in 13N-ammonia myocardial perfusion PET/CT
    Do, Yong Ho
    Lee, Hong Jae
    Kim, Jin Eui
    Im, Hyung Jun
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [17] 13N-Ammonia PET/CT Detection of Myocardial Perfusion Abnormalities in Beagle Dogs After Local Heart Irradiation
    Song, Jianbo
    Yan, Rui
    Wu, Zhifang
    Li, Jianguo
    Yan, Min
    Hao, Xinzhong
    Liu, Jianzhong
    Li, Sijin
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (04) : 605 - 610
  • [18] Absolute myocardial blood flow evaluation with 13N-ammonia and 3D PET-CT
    Leccisotti, L.
    Indovina, L.
    Paraggio, L.
    Calcagni, M. L.
    Giordano, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A80 - A80
  • [19] Combined evaluation of myocardial perfusion and coronary morphology in the identification of subclinical CAD Radiation exposure of 13N-ammonia PET/CT
    Vincenti, G.
    Quercioli, A.
    Zaidi, H.
    Nkoulou, R.
    Dewarrat, S.
    Rager, O.
    Ambrosio, G.
    Seimbille, Y.
    Mach, F.
    Ratib, O.
    Schindler, T. H.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2010, 49 (05): : 173 - 182
  • [20] Myocardial Flow Reserve in Coronary Artery Disease with Low Attenuation Plaque: Coronary CTA and 13N-ammonia PET Assessments
    Yamamoto, Atsushi
    Nagao, Michinobu
    Ando, Kiyoe
    Nakao, Risako
    Sakai, Akiko
    Watanabe, Eri
    Momose, Mitsuru
    Sato, Kayoko
    Fukushima, Kenji
    Sakai, Shuji
    Hagiwara, Nobuhisa
    ACADEMIC RADIOLOGY, 2022, 29 : S17 - S24