Diagnostic accuracy of 13N-ammonia myocardial perfusion imaging with PET-CT in the detection of coronary artery disease

被引:16
|
作者
Fathala, Ahmed [1 ]
Aboulkheir, Mervat [1 ,2 ]
Shoukri, Mohamamed M. [3 ]
Alsergani, Hani [4 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Radiol Nucl Med & Cardiovasc Imaging, Riyadh, Saudi Arabia
[2] Taibah Univ, Madinah, Saudi Arabia
[3] King Faisal Specialist Hosp & Res Ctr, Dept Cell Biol, Riyadh, Saudi Arabia
[4] King Faisal Specialist Hosp & Res Ctr, King Faisal Heart Inst, Riyadh, Saudi Arabia
关键词
Positron emission tomography-computed tomography myocardial perfusion imaging (PETCT MPI); N-13-ammonia positron emission tomography-computed tomography myocardial perfusion (N-13-ammonia PET-CT myocardial perfusion); coronary artery calcium score (CACS); POSITRON-EMISSION-TOMOGRAPHY; DIPYRIDAMOLE STRESS; COMPUTED-TOMOGRAPHY; PROGNOSTIC VALUE; CALCIUM SCORE; RISK-FACTORS; QUANTIFICATION;
D O I
10.21037/cdt.2018.10.12
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: N-13-ammonia positron emission tomography-computed tomography (PET-CT) is being increasingly used as a non-invasive imaging modality for evaluating patients with known or suspected coronary artery disease (CAD), but information about the diagnostic accuracy of PET-MPI is sparse. Objectives: Our objective was to determine the accuracy of N-13-ammonia PET-CT myocardial perfusion imaging (MPI) for detecting CAD. Methods: We retrospectively evaluated 383 patients with suspected CAD who underwent rest-stress (13)-Nammonia PET-CT MPI. Invasive coronary angiography (ICA) was performed within 60 days for all patients with abnormal PET-MPI findings and for selected patients with normal PET-MPI findings. Results: The mean age of the patients was 64 +/- 11 years, and the mean body mass index was 32 +/- 7 kg/m(2). Stress perfusion defects were identified in 147 (34%) out of a total of 383 patients. ICA was performed in 213 patients (145 patients with abnormal PET and 68 patients with normal PET). The sensitivity of PET-MPI for detection of obstructive CAD based on >= 50% stenosis was 90%; specificity, 90%; positive predictive value, 96%; negative predictive value, 76%; and diagnostic accuracy, 80%. Conclusions: PET-MPI with N-13-ammonia affords high sensitivity and overall accuracy for detecting CAD. The addition of coronary artery calcium score (CACS) can improve CAD risk stratification.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 50 条
  • [21] Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography
    Lee, Joo Myung
    Kim, Chee Hae
    Koo, Bon-Kwon
    Hwang, Doyeon
    Park, Jonghanne
    Zhang, Jinlong
    Tong, Yaliang
    Jeon, Ki-Hyun
    Bang, Ji-In
    Suh, Minseok
    Paeng, Jin Chul
    Cheon, Gi Jeong
    Na, Sang-Hoon
    Ahn, Jung-Min
    Park, Seung-Jung
    Kim, Hyo-Soo
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (09)
  • [22] 13N-ammonia myocardial perfusion imaging with a PET/CT scanner: impact on clinical decision making and cost-effectiveness
    Patrick T. Siegrist
    Lars Husmann
    Martina Knabenhans
    Oliver Gaemperli
    Ines Valenta
    Tobias Hoefflinghaus
    Hans Scheffel
    Paul Stolzmann
    Hatem Alkadhi
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 889 - 895
  • [23] 13N-ammonia myocardial perfusion imaging with a PET/CT scanner:: impact on clinical decision making and cost-effectiveness
    Siegrist, Patrick T.
    Husmann, Lars
    Knabenhans, Martina
    Gaemperli, Oliver
    Valenta, Ines
    Hoefflinghaus, Tobias
    Scheffel, Hans
    Stolzmann, Paul
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (05) : 889 - 895
  • [24] Effect of Referral Bias on the Diagnostic Accuracy of N-13 Ammonia and Rubidium-82 Myocardial Perfusion Imaging with Positron Emission Tomography in the Detection of Coronary Artery Disease
    Syed, Imran S.
    Miller, Todd
    Gibbons, Raymond J.
    Askew, John W.
    Hodge, David
    Chareonthaitawee, Parithaya
    CIRCULATION, 2008, 118 (18) : S608 - S608
  • [25] Myocardial perfusion reserve compared with peripheral perfusion reserve: A 13N-ammonia PET study
    Scholtens, Asbjorn M.
    Dierckx, Rudi
    Tio, Rene
    Willems, Antoon T. M.
    Zeebregts, Clark
    Boersma, Hendrikus H.
    Glaudemans, Andor W. J. M.
    Slart, Riemer H. J. A.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [26] Diagnostic performance of coronary flow reserve ratio for the detection of coronary artery disease on 13N-ammonia positron emission tomography
    Kawamura, G.
    Okayama, H.
    Kawaguchi, N.
    Kido, S.
    Matsuda, K.
    Aono, T.
    Kosaki, T.
    Hosokawa, S.
    Tanaka, Y.
    Shigematsu, T.
    Kawada, Y.
    Hiasa, G.
    Yamada, T.
    Matsuoka, H.
    Kazatani, Y.
    EUROPEAN HEART JOURNAL, 2018, 39 : 346 - 347
  • [27] 13N-Ammonia myocardial blood flow quantitation in patient with aneurismal coronary artery disease
    Juan Carlos Plata-Corona
    Isabel Carvajal-Juarez
    Nilda Espinola-Zavaleta
    Felix Damas-De los Santos
    Belen Rivera-Bravo
    Erick Alexanderson-Rosas
    Journal of Nuclear Cardiology, 2022, 29 : 1826 - 1831
  • [28] 13N-ammonia PET as a measurement of hindlimb perfusion in a mouse model of peripheral artery occlusive disease
    Penuelas, Ivan
    Aranguren, Xabier L.
    Abizanda, Gloria
    Marti-Climent, Josep Maria
    Uriz, Maialen
    Ecay, Margarita
    Collantes, Maria
    Quincoces, Gernma
    Richter, Jose A.
    Prosper, Felipe
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1216 - 1223
  • [29] 13N-Ammonia myocardial blood flow quantitation in patient with aneurismal coronary artery disease
    Plata-Corona, Juan Carlos
    Carvajal-Juarez, Isabel
    Espinola-Zavaleta, Nilda
    de los Santos, Felix Damas
    Rivera-Bravo, Belen
    Alexanderson-Rosas, Erick
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (04) : 1826 - 1831
  • [30] Quantitative analysis of myocardial perfusion in patients with systemic lupus erythematosus assessed with 13N-ammonia PET/CT
    Alexanderson, Erick
    Martinez Aguilar, Myriam
    Jordan Rios, Antonio
    Magana Bailon, Elisa
    Maury Ordaz, Sergio
    Juarez Orozco, Luis
    Hernandez, Salvador
    Guizar, Carlos
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55