Large volume room temperature gamma-ray spectrometers from CdxZn1-xTe

被引:15
|
作者
Lund, JC
VanScyoc, JM
James, RB
McGregor, DS
Olsen, RW
机构
[1] Sandia National Laboratories, MS-9409, Livermore
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 380卷 / 1-2期
关键词
D O I
10.1016/S0168-9002(96)00323-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent developments in Cd1-xZnxTe (CZT) crystal growth technology have enabled the production of large samples of detector grade material. In this paper we discuss the technical issues associated with building large volume CZT detectors (> 10 cm(3)) for use in gamma-ray spectroscopy. In particular, an analysis of the electronic noise in CZT devices and how it scales with detector size is presented, along with a discussion of methods to reduce noise in large CZT detector systems. The degradation of energy resolution caused by charge collection problems is also discussed and the use of electronic signal processing and improved device design to minimize charge collection effects are described.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [41] Low energy prompt gamma-ray tests of a large volume BGO detector
    Naqvi, A. A.
    Kalakada, Zameer
    Al-Anezi, M. S.
    Raashid, M.
    Khateeb-ur-Rehman
    Maslehuddin, M.
    Garwan, M. A.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (01) : 222 - 226
  • [42] ZnXCd1-XTe room temperature x-ray detector development
    Witteles, EM
    Nelson, RD
    Dasarathy, H
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 415 - 423
  • [43] Hand-held gamma-ray Imaging sensors using room-temperature 3-dimensional position-sensitive semiconductor spectrometers
    He, Z
    Lehner, C
    Zhang, F
    Wehe, DK
    Knoll, GF
    Berry, J
    Du, YF
    UNATTENDED RADIATION SENSOR SYSTEMS FOR REMOTE APPLICATIONS, 2002, 632 : 209 - 215
  • [44] Gamma-ray spectroscopy of nuclei with large deformationsResults from GAMMASPHERE
    P. Fallon
    The European Physical Journal A - Hadrons and Nuclei, 2003, 20 : 9 - 14
  • [45] CALCULATION OF GAMMA-RAY DISTRIBUTIONS AT LARGE DISTANCES FROM SOURCES
    NIKOLAISHVILI, SS
    IORDANIS.EA
    DZHGARKA.NN
    GABRASHV.AI
    ATOMNAYA ENERGIYA, 1972, 32 (06): : 504 - +
  • [46] Heavy metal ternary halides for room-temperature x-ray and gamma-ray detection
    Liu, Zhifu
    Peters, John A.
    Stoumpos, Constantinos C.
    Sebastian, Maria
    Wessels, Bruce W.
    Im, Jino
    Freeman, Arthur J.
    Kanatzidis, Mercouri G.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [47] ROOM-TEMPERATURE SOLID-STATE DETECTORS FOR GAMMA-RAY BURST SPECTROSCOPY
    DESAI, UD
    PANTAZIS, J
    SHAH, K
    ASTROPHYSICS AND SPACE SCIENCE, 1995, 231 (1-2) : 487 - 491
  • [48] Room temperature X- and gamma-ray detectors using thallium bromide crystals
    Hitomi, K
    Muroi, O
    Shoji, T
    Suehiro, T
    Hiratate, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 160 - 164
  • [49] IMPROVED SPECTROMETER PERFORMANCE OF CADMIUM SELENIDE ROOM-TEMPERATURE GAMMA-RAY DETECTOR
    ROTH, M
    BURGER, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 407 - 410
  • [50] Room temperature X- and gamma-ray detectors using thallium bromide crystals
    Hitomi, K.
    Muroi, O.
    Shoji, T.
    Suehiro, T.
    Hiratate, Y.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 436 (1-2): : 160 - 164