Large volume room temperature gamma-ray spectrometers from CdxZn1-xTe

被引:15
|
作者
Lund, JC
VanScyoc, JM
James, RB
McGregor, DS
Olsen, RW
机构
[1] Sandia National Laboratories, MS-9409, Livermore
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 380卷 / 1-2期
关键词
D O I
10.1016/S0168-9002(96)00323-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent developments in Cd1-xZnxTe (CZT) crystal growth technology have enabled the production of large samples of detector grade material. In this paper we discuss the technical issues associated with building large volume CZT detectors (> 10 cm(3)) for use in gamma-ray spectroscopy. In particular, an analysis of the electronic noise in CZT devices and how it scales with detector size is presented, along with a discussion of methods to reduce noise in large CZT detector systems. The degradation of energy resolution caused by charge collection problems is also discussed and the use of electronic signal processing and improved device design to minimize charge collection effects are described.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [21] X-RAY NEAR-EDGE STRUCTURE OF THE II-VI GROUP TERNARY COMPOUNDS - EXPERIMENTAL AND THEORETICAL-STUDIES OF CDXHG1-XTE AND CDXZN1-XTE
    KISIEL, A
    DAHR, AIA
    LEE, PM
    DALBA, G
    FORNASINI, P
    BURATTINI, E
    PHYSICAL REVIEW B, 1990, 42 (17) : 11114 - 11122
  • [23] Iodine based compound semiconductors for room temperature gamma-ray spectroscopy
    Lintereur, Azaree T.
    Qiu, Wei
    Nino, Juan C.
    Baciak, James E.
    OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY IV, 2008, 6945
  • [24] Schottky junctions on semi-insulating LEC gallium arsenide for X- and gamma-ray spectrometers operated at and below room temperature
    Bertuccio, G
    Pullia, A
    Canali, C
    Nava, F
    Lanzieri, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (02) : 117 - 124
  • [25] LARGE-VOLUME PLASTIC DETECTOR FOR AERIAL GAMMA-RAY SPECTROSCOPY
    DUVAL, JS
    PITKIN, JA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 (JUN): : 118 - 118
  • [26] LARGE VOLUME LITHIUM-DRIFTED GERMANIUM GAMMA-RAY DETECTORS
    FIEDLER, HJ
    HUGHES, LB
    KENNETT, TJ
    PRESTWICH, WV
    WALL, BJ
    NUCLEAR INSTRUMENTS & METHODS, 1966, 40 (02): : 229 - +
  • [27] Large-volume thallium bromide detectors for gamma-ray spectroscopy
    Hitomi, K
    Muroi, O
    Matsumoto, M
    Shoji, T
    Hiratate, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2313 - 2316
  • [28] High pressure xenon gamma-ray large volume spectrometer.
    Ulin, SE
    Vlasik, KF
    Gratchev, VM
    Dmitrenko, VV
    Kondakova, ON
    Uteshev, ZM
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 577 - 581
  • [29] Material inhomogeneities in Cd1-xZnxTe and their effects on large volume gamma-ray detectors
    VanScyoc, JM
    Lund, JC
    Morse, DH
    Antolak, AJ
    Olsen, RW
    James, RB
    Schieber, M
    Yoon, H
    Goorsky, MS
    Toney, J
    Schlesinger, TE
    JOURNAL OF ELECTRONIC MATERIALS, 1996, 25 (08) : 1323 - 1327
  • [30] TRANSIENT-BEHAVIOR OF THE 2ND-ORDER OPTICAL PROCESS IN CDXZN1-XTE - TRANSFORMATION FROM LUMINESCENCE INTO RAMAN-SCATTERING
    NAKAMURA, A
    SHIMURA, M
    HIRAI, M
    AIHARA, M
    NAKASHIMA, S
    PHYSICAL REVIEW B, 1987, 35 (03): : 1281 - 1287