Large volume room temperature gamma-ray spectrometers from CdxZn1-xTe

被引:15
|
作者
Lund, JC
VanScyoc, JM
James, RB
McGregor, DS
Olsen, RW
机构
[1] Sandia National Laboratories, MS-9409, Livermore
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 380卷 / 1-2期
关键词
D O I
10.1016/S0168-9002(96)00323-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent developments in Cd1-xZnxTe (CZT) crystal growth technology have enabled the production of large samples of detector grade material. In this paper we discuss the technical issues associated with building large volume CZT detectors (> 10 cm(3)) for use in gamma-ray spectroscopy. In particular, an analysis of the electronic noise in CZT devices and how it scales with detector size is presented, along with a discussion of methods to reduce noise in large CZT detector systems. The degradation of energy resolution caused by charge collection problems is also discussed and the use of electronic signal processing and improved device design to minimize charge collection effects are described.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [31] Interband transitions in CdxZn1-xTe/ZnTe strained single quantum wells grown by double-well temperature-gradient vapor deposition
    Park, HL
    Lee, SH
    Kim, TW
    COMPOUND SEMICONDUCTORS 1995, 1996, 145 : 425 - 430
  • [32] GAMMA-RAY ENERGY RESOLUTION WITH NAI-T1I SCINTILLATION SPECTROMETERS
    BORKOWSKI, CJ
    CLARK, RL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (11): : 1046 - 1050
  • [33] Modeling and simulation of uniformity effects in Cd1-xZnxTe gamma-ray spectrometers
    Toney, JE
    Schlesinger, TE
    James, RB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (01) : 105 - 113
  • [34] GAMMA-RAY SPECTRA DETECTED WITH HGL-2 AT ROOM-TEMPERATURE
    PUSCHERT, W
    SCHOLZ, H
    APPLIED PHYSICS LETTERS, 1976, 28 (06) : 357 - 359
  • [35] Gamma-ray spectra in the positron-annihilation process of molecules at room temperature
    Tang, Lin
    Ma, Xiaoguang
    Sui, Jipeng
    Wang, Meishan
    Yang, Chuanlu
    PHYSICS LETTERS A, 2020, 384 (24)
  • [36] ADVANTAGES AND LIMITATIONS OF CADMIUM SELENIDE ROOM-TEMPERATURE GAMMA-RAY DETECTORS
    ROTH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (02): : 291 - 298
  • [37] ROOM-TEMPERATURE GAMMA-RAY INDUCED SINTERING OF ZINC-OXIDE
    WYSOCKI, W
    SUGIER, H
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1975, 20 (03): : 191 - 196
  • [38] Room temperature X- and gamma-ray spectroscopy with silicon drift detectors
    Strüder, L
    Hartmann, R
    Kemmer, S
    Krause, N
    Stötter, D
    Lutz, G
    Solc, P
    Holl, P
    Lechner, P
    Leutenegger, P
    Kemmer, J
    Soltau, H
    Stötter, R
    Weber, U
    Castoldi, A
    Fiorini, C
    Gatti, E
    Guazzoni, C
    Longoni, A
    Sampietro, M
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 29 - 47
  • [39] DERIVATIVE METHOD UNFOLDING OF GAMMA-RAY SPECTRA FROM NE-213 SPECTROMETERS
    KORSAH, JK
    MILLER, WH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 623 - 624
  • [40] DERIVATIVE METHOD UNFOLDING OF GAMMA-RAY SPECTRA FROM NE-213 SPECTROMETERS
    KORSAH, JK
    MILLER, WH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 441 - 443