Large volume room temperature gamma-ray spectrometers from CdxZn1-xTe

被引:15
|
作者
Lund, JC
VanScyoc, JM
James, RB
McGregor, DS
Olsen, RW
机构
[1] Sandia National Laboratories, MS-9409, Livermore
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1996年 / 380卷 / 1-2期
关键词
D O I
10.1016/S0168-9002(96)00323-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent developments in Cd1-xZnxTe (CZT) crystal growth technology have enabled the production of large samples of detector grade material. In this paper we discuss the technical issues associated with building large volume CZT detectors (> 10 cm(3)) for use in gamma-ray spectroscopy. In particular, an analysis of the electronic noise in CZT devices and how it scales with detector size is presented, along with a discussion of methods to reduce noise in large CZT detector systems. The degradation of energy resolution caused by charge collection problems is also discussed and the use of electronic signal processing and improved device design to minimize charge collection effects are described.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [1] LARGE-VOLUME COAXIAL GERMANIUM GAMMA-RAY SPECTROMETERS
    MALM, HL
    FOWLER, IL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (01) : 62 - +
  • [2] Large volume HgI2 gamma-ray spectrometers
    He, Z
    Baciak, J
    UNATTENDED RADIATION SENSOR SYSTEMS FOR REMOTE APPLICATIONS, 2002, 632 : 113 - 117
  • [3] SEMICONDUCTOR RADIATION DETECTORS - LARGE VOLUME GERMANIUM GAMMA-RAY SPECTROMETERS
    TRAMMELL, RC
    WAGNER, S
    NUCLEAR ENGINEERING INTERNATIONAL, 1972, 17 (192): : 389 - &
  • [4] Lead iodide x-ray and gamma-ray spectrometers for room and high temperature operation
    Hermon, H
    James, RB
    Lund, J
    Cross, E
    Antolak, A
    Morse, DH
    Medlin, DL
    Soria, E
    Van Scyoc, J
    Brunett, B
    Schieber, M
    Schlesinger, TE
    Toney, J
    Goorsky, M
    Yoon, H
    Burger, A
    Salary, L
    Chen, KT
    Chang, YC
    Shah, K
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 361 - 368
  • [5] CdZnTe pixel array detectors and implications for producing large volume gamma-ray spectrometers
    Brunett, BA
    Van Scyoc, JM
    James, RB
    Schlesinger, TE
    JOURNAL OF APPLIED PHYSICS, 1999, 86 (07) : 3926 - 3933
  • [6] Temperature- and size-dependent photoluminescence in colloidal CdTe and CdxZn1-xTe quantum dots
    Balakrishnan, Janani
    Preethi, L. K.
    Sreeshma, D.
    Jagtap, Amardeep
    Madapu, Kishore K.
    Dhara, Sandip
    Rao, K. S. R. Koteswara
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (14)
  • [7] On the active volume of cadmium zinc telluride gamma-ray spectrometers
    Lund, JC
    Brunett, BA
    Viles, TP
    Hilton, NR
    James, RB
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 199 - 204
  • [8] The Development of Large-area Plastic Gamma-ray Spectrometers
    Burt, Christopher
    Ramsden, David
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 461 - +
  • [9] EUROBALL - LARGE GAMMA-RAY SPECTROMETERS THROUGH EUROPEAN COLLABORATIONS
    BECK, FA
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 1992, 28 : 443 - 461
  • [10] EFFICIENCY CALIBRATION OF GAMMA-RAY SPECTROMETERS FOR VOLUME-SOURCE GEOMETRY