Maximum embryo absorbed dose from intravenous urography: Interhospital variations

被引:8
|
作者
Damilakis, J
Perisinakis, K
Koukourakis, M
Gourtsoyiannis, N
机构
[1] Department of Medical Physics, University of Crete, 711 10 Stavrakia, Iraklion, Crete
[2] Department of Radiology, University of Crete, 711 10 Stavrakia, Iraklion, Crete
[3] Department of Radiotherapy, University Hospital of Iraklion, Iraklion, Crete
关键词
D O I
10.1093/oxfordjournals.rpd.a032079
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to determine the maximum embryo dose during intravenous urography (IVU) examinations, when inadvertent irradiation of a pregnant woman occurs, and to investigate the variation of doses received from different institutions. Doses at average embryo depth from IVU examinations have been measured in four institutions, using a Rando phantom and thermoluminescent crystals. In order to estimate the maximum range of embryo doses, radiologists were asked to carry out the examinations with the same technique as in female patients with acute ureteral obstruction. The range of doses estimated at embryo depth for the institutions participating in this study was 5.77 to 35.2 mGy. The considerable interhospital variation found in dose can be explained by different equipment and techniques used. A simple method of estimating embryo dose from pelvic radiographs reported previously was found to be also applicable to IVU examinations. Absorbed dose at 6 sm, the average embryo depth, was found significantly less than 50 mGy.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [21] Site - Specific Skeletal Dosimetry: From Mean Absorbed Dose to Absorbed Dose Distribution
    Papanikolos, G.
    Lyra, M.
    Kontogeorgakos, D.
    Jordanou, J.
    Vlahos, L.
    Limouris, G. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S207 - S207
  • [22] DANGERS OF INTRAVENOUS UROGRAPHY IN DIABETICS SUFFERING FROM A NEPHROPATHY
    GIUDICEL.C
    MELIN, R
    DORNE, R
    LOMBARD, C
    MASBERNA.A
    LYON MEDICAL, 1973, 230 (19): : 737 - 741
  • [23] Intravenous urography, an examination from the past without a future
    Petit-Perrin, D
    PROGRES EN UROLOGIE, 2002, 12 (03): : 535 - 535
  • [24] COMPUTATION OF DISTRIBUTION OF ABSORBED DOSE AND ABSORBED DOSE RATE FROM A SCANNING ELECTRON BEAM
    ROZENFELD, M
    LANZL, LH
    NEWTON, CM
    SKAGGS, LS
    STRAHLENTHERAPIE, 1969, 138 (06) : 651 - +
  • [25] CT in ureterolithiasis with a radiation dose equal to intravenous urography:: Results in 209 patients
    Knöpfle, E
    Hamm, M
    Wartenberg, S
    Bohndorf, K
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (12): : 1667 - 1672
  • [26] CALCULATION OF ABSORBED DOSE FROM RADIOPHARMACEUTICALS
    HUSAK, V
    JOURNAL OF NUCLEAR MEDICINE, 1973, 14 (11) : 876 - 877
  • [27] ABSORBED DOSE ESTIMATES FROM RADIONUCLIDES
    HARBERT, JC
    POLLINA, R
    CLINICAL NUCLEAR MEDICINE, 1984, 9 (04) : 210 - 221
  • [28] Accidental embryo irradiation during barium enema examinations - An estimation of absorbed dose
    Damilakis, J
    Perisinakis, K
    Grammatikakis, J
    Panayiotakis, G
    Gourtsoyiannis, N
    INVESTIGATIVE RADIOLOGY, 1996, 31 (04) : 242 - 245
  • [29] Intravenous urography during renal pain from ureteral stricture
    McCahey, JF
    Fetter, JS
    JOURNAL OF UROLOGY, 1942, 48 (06): : 622 - 627
  • [30] Reduction of absorbed dose in storage phosphor urography by significant lowering of tube voltage and adjustment of image display parameters
    Wiltz, HJ
    Petersen, U
    Axelsson, B
    ACTA RADIOLOGICA, 2005, 46 (04) : 391 - 395