Reduction of absorbed dose in storage phosphor urography by significant lowering of tube voltage and adjustment of image display parameters

被引:10
|
作者
Wiltz, HJ
Petersen, U
Axelsson, B
机构
[1] Cent Hosp Vaxjo, Dept Radiol, Vaxjo, Sweden
[2] Cent Hosp Vaxjo, Dept Biomed Engn & Med Phys, Vaxjo, Sweden
关键词
experimental; radiation exposure; image quality; technology; urography; digital;
D O I
10.1080/02841850510021184
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate whether image quality in storage phosphor urography can be maintained when the X-ray tube voltage is significantly lowered to give a lower patient dose. Material and Methods: Initial phantom studies were used to establish exposure settings at 53 kV that gave signal-to-noise ratios for contrast media structures equivalent to those obtained at the reference kilovoltage of 69 kV. Dose area product and image quality, assessed by image quality criteria and visual grading, were then recorded for 44 patients drawn at random to be examined by either the standard or modified technique. Results: Absorbed dose could be reduced by more than 30% without any significant change in image quality in manually controlled exposures and by 13% in exposures controlled by AEC. Conclusion: It might be possible to lower the tube voltage in digital examinations involving contrast media as a means of lowering patient dose. The image display parameters need to be adjusted to maintain image quality.
引用
收藏
页码:391 / 395
页数:5
相关论文
共 18 条
  • [1] VOLTAGE AND DOSE REDUCTION IN STORAGE PHOSPHOR DIGITAL MAMMOGRAPHY
    OESTMANN, JW
    KOPANS, D
    HALL, DA
    MCCARTHY, KA
    RUBENS, JR
    GREENE, R
    INVESTIGATIVE RADIOLOGY, 1988, 23 (09) : S24 - S24
  • [2] Evaluation of image quality and radiation dose in computed tomography urography following tube voltage optimisation
    Saidu, A. M.
    Garba, I.
    Abba, M.
    Yahuza, M. A.
    Yusuf, L.
    Tahir, N. M.
    Garko, S. S.
    RADIOGRAPHY, 2024, 30 (01) : 301 - 307
  • [3] Reducing dose in urography while maintaining image quality - a comparison of storage phosphor plates and a flat-panel detector
    Jansson, M
    Geijer, H
    Persliden, J
    Andersson, T
    EUROPEAN RADIOLOGY, 2006, 16 (01) : 221 - 226
  • [4] Reducing dose in urography while maintaining image quality—a comparison of storage phosphor plates and a flat-panel detector
    Margareta Jansson
    Håkan Geijer
    Jan Persliden
    Torbjörn Andersson
    European Radiology, 2006, 16 : 221 - 226
  • [5] FLUOROSCOPIC DOSE REDUCTION AND IMAGE MANIPULATION USING A SILICON TARGET STORAGE TUBE
    MISTRETTA, CA
    MORAN, PR
    CAMERON, JR
    ORT, MG
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (03): : 447 - +
  • [6] Circle of Willis at CT angiography: Dose reduction and image quality - reducing tube voltage and increasing tube current settings
    Waaijer, Annet
    Prokop, Mathias
    Velthuis, Birgitta K.
    Bakker, Chris J. G.
    de Kort, Gerard A. P.
    van Leeuwen, Maarten S.
    RADIOLOGY, 2007, 242 (03) : 832 - 839
  • [7] Organ Dose Reduction by Lowering Tube Voltage from 120kVp to 80kVp for Fixed Tube Current Chest CT Scans
    Khatonabadi, M.
    Zhang, D.
    Turner, A.
    DeMarco, J.
    Cody, D.
    Stevens, D.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Individualized kV Selection and Tube Current Reduction in Excretory Phase Computed Tomography Urography: Potential for Radiation Dose Reduction and the Contribution of Iterative Reconstruction to Image Quality
    Froemming, Adam T.
    Kawashima, Akira
    Takahashi, Naoki
    Hartman, Robert P.
    Nathan, Mark A.
    Carter, Rickey E.
    Yu, Lifeng
    Leng, Shuai
    Kagoshima, Hiroki
    McCollough, Cynthia H.
    Fletcher, Joel G.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 551 - 559
  • [9] Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms
    Buls, Nico
    Van Gompel, Gert
    Van Cauteren, Toon
    Nieboer, Koenraad
    Willekens, Inneke
    Verfaillie, Guy
    Evans, Paul
    Macholl, Sven
    Newton, Ben
    de Mey, Johan
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 1023 - 1031
  • [10] Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms
    Nico Buls
    Gert Van Gompel
    Toon Van Cauteren
    Koenraad Nieboer
    Inneke Willekens
    Guy Verfaillie
    Paul Evans
    Sven Macholl
    Ben Newton
    Johan de Mey
    European Radiology, 2015, 25 : 1023 - 1031