Do SEII Electrons Really Degrade SEM Image Quality?

被引:8
|
作者
Bernstein, Gary H. [1 ]
Carter, Andrew D. [2 ]
Joy, David C. [3 ]
机构
[1] Univ Notre Dame, Dept Elect Engn, Ctr Nano Sci & Technol, Notre Dame, IN 46556 USA
[2] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
[3] Univ Tennessee, Dept Mat Sci & Engn, Knoxville, TN 37996 USA
关键词
scanning electron microscopy; backscattered electrons; secondary electrons; electron beam lithography; Monte Carlo simulations; MICROSCOPY;
D O I
10.1002/sca.21027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Generally, in scanning electron microscopy (SEM) imaging, it is desirable that a high-resolution image be composed mainly of those secondary electrons (SEs) generated by the primary electron beam, denoted SEI. However, in conventional SEM imaging, other, often unwanted, signal components consisting of backscattered electrons (BSEs), and their associated SEs, denoted SEII, are present; these signal components contribute a random background signal that degrades contrast, and therefore signal-to-noise ratio and resolution. Ideally, the highest resolution SEM image would consist only of the SEI component. In SEMs that use conventional pinhole lenses and their associated EverhartThornley detectors, the image is composed of several components, including SEI, SEII, and some BSE, depending on the geometry of the detector. Modern snorkel lens systems eliminate the BSEs, but not the SEIIs. We present a microfabricated diaphragm for minimizing the unwanted SEII signal components. We present evidence of improved imaging using a microlithographically generated pattern of Au, about 500 nm thick, that blocks most of the undesired signal components, leaving an image composed mostly of SEIs. We refer to this structure as a spatial backscatter diaphragm. SCANNING 35:1-6, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] QUALITY - WHAT DO SOME OF THE ENGLISH TERMS USED REALLY MEAN
    PAGE, AG
    THORACIC AND CARDIOVASCULAR SURGEON, 1990, 38 (02): : 99 - 100
  • [42] Spatial resolution, information depth and sem-image contrast of subsurface structures obtained in backscattered electrons
    M. V. Lomonosov Moscow Stt. Univ., Moscow, Russia
    Surface Investigation X-Ray, Synchrotron and Neutron Techniques, 2001, 16 (12): : 1823 - 1831
  • [43] Do we really have to consider covariance matrices for image feature points?
    Kanazawa, Y
    Kanatani, K
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART III-FUNDAMENTAL ELECTRONIC SCIENCE, 2003, 86 (01): : 1 - 10
  • [44] Improving SEM Image Quality Using Pixel-Super Resolution Technique
    Lee, Myungjun
    Cantone, Jason
    Xu, Ji
    Sun, Lei
    Kim, Ryoung-han
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXVIII, 2014, 9050
  • [45] SEM Image Quality Assessment Based on Intuitive Morphology and Deep Semantic Features
    Wang, Haoran
    Li, Shiyin
    Ding, Jicun
    Li, Suyan
    Dong, Liang
    Lu, Zhaolin
    IEEE ACCESS, 2022, 10 : 111377 - 111388
  • [46] DO INTERNAL-IMAGE CENTERS IN AgBr EMULSIONS TRAP HOLES OR ELECTRONS?
    Spencer, H.E.
    Marchetti, A.P.
    Journal of imaging science, 1986, 30 (03): : 111 - 113
  • [47] DO INTERNAL-IMAGE CENTERS IN AGBR EMULSIONS TRAP HOLES OR ELECTRONS
    SPENCER, HE
    MARCHETTI, AP
    JOURNAL OF IMAGING SCIENCE, 1986, 30 (03): : 111 - 113
  • [48] QUALITY OF LIFE IN RHEUMATOID ARTHRITIS: HOW MUCH DO WE REALLY KNOW?
    Rolfe, F.
    Kusel, J.
    Brooks-Rooney, C.
    Leonard, S. A.
    VALUE IN HEALTH, 2013, 16 (03) : A226 - A226
  • [49] Measuring quality of life after esophagectomy: Do we really need to go there?
    Kesler, Kenneth A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (03): : 631 - 632
  • [50] Do we really have provable Best Practices that ensure Software Quality?
    Thompson, J. Barrie
    QSIC 2006: Sixth International Conference on Quality Software, Proceedings, 2006, : 3 - 3