Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation

被引:21
|
作者
Robison, Sean [1 ]
Karur, Gauri Rani [1 ]
Wald, Rachel M. [1 ,2 ]
Thavendiranathan, Paaladinesh [1 ,2 ]
Crean, Andrew M. [1 ,2 ]
Hanneman, Kate [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Dept Med Imaging, Toronto Gen Hosp, 585 Univ Ave,1PMB 298, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Toronto Gen Hosp, Div Cardiol, Dept Med,Peter Munk Cardiac Ctr, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Cardiovascular magnetic resonance (CMR); T1; mapping; Extracellular volume (ECV); Noninvasive hemoglobin monitoring; Hematocrit; DIFFUSE MYOCARDIAL FIBROSIS; SPIN-LATTICE-RELAXATION; HEMOGLOBIN CONCENTRATION; CLINICAL-APPLICATIONS; ACCURACY; SURGERY; VALIDATION; SERUM; COOXIMETER; FRACTION;
D O I
10.1186/s12968-018-0443-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Calculation of cardiovascular magnetic resonance (CMR) extracellular volume (ECV) requires input of hematocrit, which may not be readily available. The purpose of this study was to evaluate the diagnostic accuracy of ECV calculated using various noninvasive measures of hematocrit compared to ECV calculated with input of laboratory hematocrit as the reference standard. Methods: One hundred twenty three subjects (47.7 +/- 14.1 years; 42% male) were prospectively recruited for CMR T1 mapping between August 2016 and April 2017. Laboratory hematocrit was assessed by venipuncture. Noninvasive hematocrit was assessed with a point-of-care (POC) device (Pronto-7 (R) Pulse CO-Oximeter (R), Masimo Personal Health, Irvine, California, USA) and by synthetic derivation based on the relationship with blood pool T1 values. Left ventricular ECV was calculated with input of laboratory hematocrit (Lab-ECV), POC hematocrit (POC-ECV), and synthetic hematocrit (synthetic-ECV), respectively. Statistical analysis included Wilcoxon signed-rank test, Bland-Altman analysis, receiver-operating curve analysis and intra-class correlation (ICC). Results: There was no significant difference between Lab-ECV and POC-ECV (27.1 +/- 4.7% vs. 27.3 +/- 4.8%, p=0.106), with minimal bias and modest precision (bias - 0.18%, 95% CI [-2.85, 2.49]). There was no significant difference between Lab-ECV and synthetic-ECV (26.7 +/- 4.4% vs. 26.5 +/- 4.3%, p = 0.084) in subjects imaged at 1.5 T, although bias was slightly higher and limits of agreement were wider (bias 0.23%, 95% CI [-2.82, 3.27]). For discrimination of abnormal Lab-ECV >= 30%, POC-ECV had good diagnostic performance (sensitivity 85%, specificity 96%, accuracy 94%, and AUC 0.902) and synthetic-ECV had moderate diagnostic performance (sensitivity 71%, specificity 98%, accuracy 93%, and AUC 0.849). POC-ECV had excellent test-retest (ICC 0.994, 95% CI[0.987, 0.997]) and inter-observer agreement (ICC 0.974, 95% CI[0.929, 0.991]). Conclusions: Myocardial ECV can be accurately and reproducibly calculated with input of hematocrit measured using a noninvasive POC device, potentially overcoming an important barrier to implementation of ECV. Further evaluation of synthetic ECV is required prior to clinical implementation.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A noninvasive method to study the evolution of extracellular fluid volume in mice using time-domain nuclear magnetic resonance
    Morla, Luciana
    Shore, Oliver
    Lynch, I. Jeanette
    Merritt, Matthew E.
    Wingo, Charles S.
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2020, 319 (01) : F115 - F124
  • [42] Letter by Iles and Taylor Regarding Article, "Comprehensive Validation of Cardiovascular Magnetic Resonance Techniques for the Assessment of Myocardial Extracellular Volume"
    Iles, Leah M.
    Taylor, Andrew J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (04) : E25 - E25
  • [43] Assessment of disease activity in rheumatoid arthritis using magnetic resonance imaging: Quantification of Pannus volume in the hands
    Sugimoto, H
    Takeda, A
    Kano, S
    BRITISH JOURNAL OF RHEUMATOLOGY, 1998, 37 (08): : 854 - 861
  • [44] Assessment of disease activity in rheumatoid arthritis using magnetic resonance imaging: quantification of pannus volume in the hands
    Smith, MD
    RHEUMATOLOGY, 1999, 38 (07) : 680 - 680
  • [45] Noninvasive assessment of coronary vasodilation using cardiovascular magnetic resonance in patients at high risk for coronary artery disease
    Patricia K Nguyen
    Craig Meyer
    Jan Engvall
    Phillip Yang
    Michael V McConnell
    Journal of Cardiovascular Magnetic Resonance, 10
  • [46] Noninvasive assessment of coronary vasodilation using cardiovascular magnetic resonance in patients at high risk for coronary artery disease
    Nguyen, Patricia K.
    Meyer, Craig
    Engvall, Jan
    Yang, Phillip
    McConnell, Michael V.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [48] Assessment of residual gastric volume using point-of-care ultrasonography in adult patients who underwent elective surgery
    T.S. Chaitra
    Sanjeev Palta
    Richa Saroa
    Swati Jindal
    Aditi Jain
    The Ultrasound Journal, 15
  • [49] Assessment of residual gastric volume using point-of-care ultrasonography in adult patients who underwent elective surgery
    Chaitra, T. S.
    Palta, Sanjeev
    Saroa, Richa
    Jindal, Swati
    Jain, Aditi
    ULTRASOUND JOURNAL, 2023, 15 (01):
  • [50] Assessment of endogenous fibrinolysis using a point-of-care assay to identify increased cardiovascular risk in patients with diabetes and ACS
    Kanji, R.
    Gue, Y. X.
    Dinarvand, D.
    Farag, M. Q.
    Gorog, D. A.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1540 - 1540