Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation

被引:21
|
作者
Robison, Sean [1 ]
Karur, Gauri Rani [1 ]
Wald, Rachel M. [1 ,2 ]
Thavendiranathan, Paaladinesh [1 ,2 ]
Crean, Andrew M. [1 ,2 ]
Hanneman, Kate [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Dept Med Imaging, Toronto Gen Hosp, 585 Univ Ave,1PMB 298, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Toronto Gen Hosp, Div Cardiol, Dept Med,Peter Munk Cardiac Ctr, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Cardiovascular magnetic resonance (CMR); T1; mapping; Extracellular volume (ECV); Noninvasive hemoglobin monitoring; Hematocrit; DIFFUSE MYOCARDIAL FIBROSIS; SPIN-LATTICE-RELAXATION; HEMOGLOBIN CONCENTRATION; CLINICAL-APPLICATIONS; ACCURACY; SURGERY; VALIDATION; SERUM; COOXIMETER; FRACTION;
D O I
10.1186/s12968-018-0443-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Calculation of cardiovascular magnetic resonance (CMR) extracellular volume (ECV) requires input of hematocrit, which may not be readily available. The purpose of this study was to evaluate the diagnostic accuracy of ECV calculated using various noninvasive measures of hematocrit compared to ECV calculated with input of laboratory hematocrit as the reference standard. Methods: One hundred twenty three subjects (47.7 +/- 14.1 years; 42% male) were prospectively recruited for CMR T1 mapping between August 2016 and April 2017. Laboratory hematocrit was assessed by venipuncture. Noninvasive hematocrit was assessed with a point-of-care (POC) device (Pronto-7 (R) Pulse CO-Oximeter (R), Masimo Personal Health, Irvine, California, USA) and by synthetic derivation based on the relationship with blood pool T1 values. Left ventricular ECV was calculated with input of laboratory hematocrit (Lab-ECV), POC hematocrit (POC-ECV), and synthetic hematocrit (synthetic-ECV), respectively. Statistical analysis included Wilcoxon signed-rank test, Bland-Altman analysis, receiver-operating curve analysis and intra-class correlation (ICC). Results: There was no significant difference between Lab-ECV and POC-ECV (27.1 +/- 4.7% vs. 27.3 +/- 4.8%, p=0.106), with minimal bias and modest precision (bias - 0.18%, 95% CI [-2.85, 2.49]). There was no significant difference between Lab-ECV and synthetic-ECV (26.7 +/- 4.4% vs. 26.5 +/- 4.3%, p = 0.084) in subjects imaged at 1.5 T, although bias was slightly higher and limits of agreement were wider (bias 0.23%, 95% CI [-2.82, 3.27]). For discrimination of abnormal Lab-ECV >= 30%, POC-ECV had good diagnostic performance (sensitivity 85%, specificity 96%, accuracy 94%, and AUC 0.902) and synthetic-ECV had moderate diagnostic performance (sensitivity 71%, specificity 98%, accuracy 93%, and AUC 0.849). POC-ECV had excellent test-retest (ICC 0.994, 95% CI[0.987, 0.997]) and inter-observer agreement (ICC 0.974, 95% CI[0.929, 0.991]). Conclusions: Myocardial ECV can be accurately and reproducibly calculated with input of hematocrit measured using a noninvasive POC device, potentially overcoming an important barrier to implementation of ECV. Further evaluation of synthetic ECV is required prior to clinical implementation.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Venous congestion assessment using point-of-care Doppler ultrasound: Welcome to the future of volume status assessment
    Koratala, Abhilash
    CLINICAL CASE REPORTS, 2021, 9 (03): : 1805 - 1807
  • [32] ironPhone: Mobile device-coupled point-of-care diagnostics for assessment of iron status by quantification of serum ferritin
    Srinivasan, Balaji
    O'Dell, Dakota
    Finkelstein, Julia L.
    Lee, Seoho
    Erickson, David
    Mehta, Saurabh
    BIOSENSORS & BIOELECTRONICS, 2018, 99 : 115 - 121
  • [33] Magnetic Bead Handling Using a Paper-Based Device for Quantitative Point-of-Care Testing
    Arias-Alpizar, Kevin
    Sanchez-Cano, Ana
    Prat-Trunas, Judit
    Sulleiro, Elena
    Bosch-Nicolau, Pau
    Salvador, Fernando
    Oliveira, Ines
    Molina, Israel
    Sanchez-Montalva, Adrian
    Baldrich, Eva
    BIOSENSORS-BASEL, 2022, 12 (09):
  • [34] Assessment of chemotherapy-induced neurotoxicity using a point-of-care nerve conduction study device
    Jokimaki, Anna
    Iivanainen, Sanna
    Mikkonen, Raija
    Mika, Kallio
    Koivunen, Jussi
    CANCER REPORTS, 2023, 6 (01)
  • [35] Incremental value of extracellular volume assessment by cardiovascular magnetic resonance imaging in risk stratifying patients with suspected myocarditis
    Graeni, Christoph
    Biere, Loic
    Eichhorn, Christian
    Kaneko, Kyoichi
    Agarwal, Vikram
    Aghayev, Ayaz
    Steigner, Michael
    Blankstein, Ron
    Jerosch-Herold, Michael
    Kwong, Raymond Y.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (06): : 1067 - 1078
  • [36] INCREMENTAL VALUE OF EXTRACELLULAR VOLUME ASSESSMENT BY CARDIOVASCULAR MAGNETIC RESONANCE IMAGING IN RISK STRATIFYING PATIENTS WITH SUSPECTED MYOCARDITIS
    Grani, Christoph
    Biere, Loic
    Eichhorn, Christian
    Kaneko, Kyoichi
    Agarwal, Vikram
    Aghayev, Ayaz
    Steigner, Michael
    Blankstein, Ron
    Jerosch-Herold, Michael
    Kwong, Raymond
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1472 - 1472
  • [37] Response to Letter Regarding Article, "Comprehensive Validation of Cardiovascular Magnetic Resonance Techniques for the Assessment of Myocardial Extracellular Volume"
    Miller, Christopher A.
    Naish, Josephine H.
    Bishop, Paul
    Coutts, Glyn
    Clark, David
    Zhao, Sha
    Ray, Simon G.
    Yonan, Nizar
    Williams, Simon G.
    Flett, Andrew S.
    Moon, James C.
    Greiser, Andreas
    Parker, Geoffrey J. M.
    Schmitt, Matthias
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (04) : E26 - E27
  • [38] Incremental value of extracellular volume assessment by cardiovascular magnetic resonance imaging in risk stratifying patients with suspected myocarditis
    Christoph Gräni
    Loïc Bière
    Christian Eichhorn
    Kyoichi Kaneko
    Vikram Agarwal
    Ayaz Aghayev
    Michael Steigner
    Ron Blankstein
    Michael Jerosch-Herold
    Raymond Y. Kwong
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1067 - 1078
  • [39] Combining extracellular volume fraction imaging and T2 quantification by cardiovascular magnetic resonance in patients with clinically suspected myocarditis
    Ulf K Radunski
    Gunnar Lund
    Fadi Obeidat
    Christian Stehning
    Gerhard Adam
    Stefan Blankenberg
    Kai Muellerleile
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [40] Quantitative assessment of chemotherapy-induced peripheral neurotoxicity using a point-of-care nerve conduction device
    Matsuoka, Ayumu
    Mitsuma, Ayako
    Maeda, Osamu
    Kajiyama, Hiroaki
    Kiyoi, Hitoshi
    Kodera, Yasuhiro
    Nagino, Masato
    Goto, Hidemi
    Ando, Yuichi
    CANCER SCIENCE, 2016, 107 (10) : 1453 - 1457