Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation

被引:21
|
作者
Robison, Sean [1 ]
Karur, Gauri Rani [1 ]
Wald, Rachel M. [1 ,2 ]
Thavendiranathan, Paaladinesh [1 ,2 ]
Crean, Andrew M. [1 ,2 ]
Hanneman, Kate [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Dept Med Imaging, Toronto Gen Hosp, 585 Univ Ave,1PMB 298, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Toronto Gen Hosp, Div Cardiol, Dept Med,Peter Munk Cardiac Ctr, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Cardiovascular magnetic resonance (CMR); T1; mapping; Extracellular volume (ECV); Noninvasive hemoglobin monitoring; Hematocrit; DIFFUSE MYOCARDIAL FIBROSIS; SPIN-LATTICE-RELAXATION; HEMOGLOBIN CONCENTRATION; CLINICAL-APPLICATIONS; ACCURACY; SURGERY; VALIDATION; SERUM; COOXIMETER; FRACTION;
D O I
10.1186/s12968-018-0443-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Calculation of cardiovascular magnetic resonance (CMR) extracellular volume (ECV) requires input of hematocrit, which may not be readily available. The purpose of this study was to evaluate the diagnostic accuracy of ECV calculated using various noninvasive measures of hematocrit compared to ECV calculated with input of laboratory hematocrit as the reference standard. Methods: One hundred twenty three subjects (47.7 +/- 14.1 years; 42% male) were prospectively recruited for CMR T1 mapping between August 2016 and April 2017. Laboratory hematocrit was assessed by venipuncture. Noninvasive hematocrit was assessed with a point-of-care (POC) device (Pronto-7 (R) Pulse CO-Oximeter (R), Masimo Personal Health, Irvine, California, USA) and by synthetic derivation based on the relationship with blood pool T1 values. Left ventricular ECV was calculated with input of laboratory hematocrit (Lab-ECV), POC hematocrit (POC-ECV), and synthetic hematocrit (synthetic-ECV), respectively. Statistical analysis included Wilcoxon signed-rank test, Bland-Altman analysis, receiver-operating curve analysis and intra-class correlation (ICC). Results: There was no significant difference between Lab-ECV and POC-ECV (27.1 +/- 4.7% vs. 27.3 +/- 4.8%, p=0.106), with minimal bias and modest precision (bias - 0.18%, 95% CI [-2.85, 2.49]). There was no significant difference between Lab-ECV and synthetic-ECV (26.7 +/- 4.4% vs. 26.5 +/- 4.3%, p = 0.084) in subjects imaged at 1.5 T, although bias was slightly higher and limits of agreement were wider (bias 0.23%, 95% CI [-2.82, 3.27]). For discrimination of abnormal Lab-ECV >= 30%, POC-ECV had good diagnostic performance (sensitivity 85%, specificity 96%, accuracy 94%, and AUC 0.902) and synthetic-ECV had moderate diagnostic performance (sensitivity 71%, specificity 98%, accuracy 93%, and AUC 0.849). POC-ECV had excellent test-retest (ICC 0.994, 95% CI[0.987, 0.997]) and inter-observer agreement (ICC 0.974, 95% CI[0.929, 0.991]). Conclusions: Myocardial ECV can be accurately and reproducibly calculated with input of hematocrit measured using a noninvasive POC device, potentially overcoming an important barrier to implementation of ECV. Further evaluation of synthetic ECV is required prior to clinical implementation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Noninvasive Assessment of Cardiopulmonary Hemodynamics Using Cardiovascular Magnetic Resonance Pulmonary Transit Time
    Segeroth, Martin
    Winkel, David Jean
    Kaufmann, Beat A.
    Strebel, Ivo
    Yang, Shan
    Cyriac, Joshy
    Wasserthal, Jakob
    Bach, Michael
    Lopez-Ayala, Pedro
    Sauter, Alexander
    Mueller, Christian
    Bremerich, Jens
    Zellweger, Michael
    Haaf, Philip
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2024, 2024
  • [22] Quantitative hematocrit measurement of whole blood in a point-of-care lateral flow device using a smartphone flow tracking app
    Frantz, Eric
    Li, Hua
    Steckl, Andrew J.
    BIOSENSORS & BIOELECTRONICS, 2020, 163 (163):
  • [23] Quantification of Myocardial Extracellular Volume Fraction in Systemic AL Amyloidosis An Equilibrium Contrast Cardiovascular Magnetic Resonance Study
    Banypersad, Sanjay M.
    Sado, Daniel M.
    Flett, Andrew S.
    Gibbs, Simon D. J.
    Pinney, Jennifer H.
    Maestrini, Viviana
    Cox, Andrew T.
    Fontana, Marianna
    Whelan, Carol J.
    Wechalekar, Ashutosh D.
    Hawkins, Philip N.
    Moon, James C.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (01) : 34 - 39
  • [24] Quantification of right ventricular extracellular volume in pulmonary hypertension using cardiac magnetic resonance imaging
    Habert, P.
    Capron, T.
    Hubert, S.
    Bentatou, Z.
    Bartoli, A.
    Tradi, F.
    Renard, S.
    Rapacchi, S.
    Guye, M.
    Bernard, M.
    Habib, G.
    Jacquier, A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (05) : 311 - 320
  • [25] Using Point-of-Care Bedside Ultrasound for Volume Assessment in Early Shock: An Outcome Study
    Mitchell, Daniel
    Gardiner, Aaron Leng Stuart
    Vanderwerff, Laura
    Jones, Steven
    Thompson, Dennis
    Leng, Poh
    CHEST, 2016, 149 (04) : 148A - 148A
  • [26] VOLUME STATUS ASSESSMENT BY VENTRICULAR FILLING PRESSURE MEASUREMENT USING POINT-OF-CARE ULTRASOUND
    Ablordeppey, Enyo
    Gharib, Amr
    Tohme, Fadi
    The, Tama
    Jaeger, Lindsay
    O'brien, Frank
    Tian, Linlin
    Theodoro, Daniel
    CRITICAL CARE MEDICINE, 2020, 48
  • [27] Early myocardial and skeletal muscle interstitial remodelling in systemic sclerosis: insights from extracellular volume quantification using cardiovascular magnetic resonance
    Barison, Andrea
    Gargani, Luna
    De Marchi, Daniele
    Aquaro, Giovanni Donato
    Guiducci, Serena
    Picano, Eugenio
    Cerinic, Marco Matucci
    Pingitore, Alessandro
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (01) : 74 - 80
  • [28] HEMATOMA VOLUME AND CLINICAL OUTCOME ON LOW-FIELD, PORTABLE, POINT-OF-CARE MAGNETIC RESONANCE IMAGING
    Yuen, M.
    Mazurek, M.
    Cahn, B.
    Shah, J.
    Kundu, P.
    Welch, E. B.
    By, S.
    Ward, A.
    Timario, N.
    Falcone, G.
    Hwang, D.
    Kim, J.
    Jasne, A.
    Gobeske, K.
    Petersen, N.
    Sharma, R.
    Schindler, J.
    Matouk, C.
    Sansing, L.
    Wira, C.
    Gilmore, E.
    Sze, G.
    Rosen, M.
    Kimberly, W. T.
    Sheth, K.
    INTERNATIONAL JOURNAL OF STROKE, 2020, 15 (1_SUPPL) : 96 - 97
  • [29] Extracellular volume fraction measurements derived from the longitudinal relaxation of blood-based synthetic hematocrit may lead to clinical errors in 3 T cardiovascular magnetic resonance
    Yongning Shang
    Xiaochun Zhang
    Xiaoyue Zhou
    Jian Wang
    Journal of Cardiovascular Magnetic Resonance, 20
  • [30] Extracellular volume fraction measurements derived from the longitudinal relaxation of blood-based synthetic hematocrit may lead to clinical errors in 3 T cardiovascular magnetic resonance
    Shang, Yongning
    Zhang, Xiaochun
    Zhou, Xiaoyue
    Wang, Jian
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20