Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation

被引:21
|
作者
Robison, Sean [1 ]
Karur, Gauri Rani [1 ]
Wald, Rachel M. [1 ,2 ]
Thavendiranathan, Paaladinesh [1 ,2 ]
Crean, Andrew M. [1 ,2 ]
Hanneman, Kate [1 ]
机构
[1] Univ Toronto, Univ Hlth Network, Dept Med Imaging, Toronto Gen Hosp, 585 Univ Ave,1PMB 298, Toronto, ON M5G 2N2, Canada
[2] Univ Toronto, Toronto Gen Hosp, Div Cardiol, Dept Med,Peter Munk Cardiac Ctr, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
Cardiovascular magnetic resonance (CMR); T1; mapping; Extracellular volume (ECV); Noninvasive hemoglobin monitoring; Hematocrit; DIFFUSE MYOCARDIAL FIBROSIS; SPIN-LATTICE-RELAXATION; HEMOGLOBIN CONCENTRATION; CLINICAL-APPLICATIONS; ACCURACY; SURGERY; VALIDATION; SERUM; COOXIMETER; FRACTION;
D O I
10.1186/s12968-018-0443-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Calculation of cardiovascular magnetic resonance (CMR) extracellular volume (ECV) requires input of hematocrit, which may not be readily available. The purpose of this study was to evaluate the diagnostic accuracy of ECV calculated using various noninvasive measures of hematocrit compared to ECV calculated with input of laboratory hematocrit as the reference standard. Methods: One hundred twenty three subjects (47.7 +/- 14.1 years; 42% male) were prospectively recruited for CMR T1 mapping between August 2016 and April 2017. Laboratory hematocrit was assessed by venipuncture. Noninvasive hematocrit was assessed with a point-of-care (POC) device (Pronto-7 (R) Pulse CO-Oximeter (R), Masimo Personal Health, Irvine, California, USA) and by synthetic derivation based on the relationship with blood pool T1 values. Left ventricular ECV was calculated with input of laboratory hematocrit (Lab-ECV), POC hematocrit (POC-ECV), and synthetic hematocrit (synthetic-ECV), respectively. Statistical analysis included Wilcoxon signed-rank test, Bland-Altman analysis, receiver-operating curve analysis and intra-class correlation (ICC). Results: There was no significant difference between Lab-ECV and POC-ECV (27.1 +/- 4.7% vs. 27.3 +/- 4.8%, p=0.106), with minimal bias and modest precision (bias - 0.18%, 95% CI [-2.85, 2.49]). There was no significant difference between Lab-ECV and synthetic-ECV (26.7 +/- 4.4% vs. 26.5 +/- 4.3%, p = 0.084) in subjects imaged at 1.5 T, although bias was slightly higher and limits of agreement were wider (bias 0.23%, 95% CI [-2.82, 3.27]). For discrimination of abnormal Lab-ECV >= 30%, POC-ECV had good diagnostic performance (sensitivity 85%, specificity 96%, accuracy 94%, and AUC 0.902) and synthetic-ECV had moderate diagnostic performance (sensitivity 71%, specificity 98%, accuracy 93%, and AUC 0.849). POC-ECV had excellent test-retest (ICC 0.994, 95% CI[0.987, 0.997]) and inter-observer agreement (ICC 0.974, 95% CI[0.929, 0.991]). Conclusions: Myocardial ECV can be accurately and reproducibly calculated with input of hematocrit measured using a noninvasive POC device, potentially overcoming an important barrier to implementation of ECV. Further evaluation of synthetic ECV is required prior to clinical implementation.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation
    Sean Robison
    Gauri Rani Karur
    Rachel M. Wald
    Paaladinesh Thavendiranathan
    Andrew M. Crean
    Kate Hanneman
    Journal of Cardiovascular Magnetic Resonance, 20
  • [2] Is a timely assessment of the hematocrit necessary for cardiovascular magnetic resonance–derived extracellular volume measurements?
    Mao-Yuan Su
    Yu-Sen Huang
    Emi Niisato
    Kelvin Chow
    Jyh-Ming Jimmy Juang
    Cho-Kai Wu
    Hsi-Yu Yu
    Lian-Yu Lin
    Shun-Chung Yang
    Yeun-Chung Chang
    Journal of Cardiovascular Magnetic Resonance, 22
  • [3] A comparative study of synthetic and venous hematocrit for calculating cardiovascular magnetic resonance-derived extracellular volume
    Yin, Jiani
    Qin, Jie
    Liu, Wangyan
    Zhu, Yinsu
    Zhou, Xiaoyue
    Wang, Yunfei
    Zhu, Xiaomei
    Xu, Yi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (04): : 769 - 778
  • [4] Is a timely assessment of the hematocrit necessary for cardiovascular magnetic resonance-derived extracellular volume measurements?
    Su, Mao-Yuan
    Huang, Yu-Sen
    Niisato, Emi
    Chow, Kelvin
    Juang, Jyh-Ming Jimmy
    Wu, Cho-Kai
    Yu, Hsi-Yu
    Lin, Lian-Yu
    Yang, Shun-Chung
    Chang, Yeun-Chung
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [5] A comparative study of synthetic and venous hematocrit for calculating cardiovascular magnetic resonance-derived extracellular volume
    Jiani Yin
    Jie Qin
    Wangyan Liu
    Yinsu Zhu
    Xiaoyue Zhou
    Yunfei Wang
    Xiaomei Zhu
    Yi Xu
    The International Journal of Cardiovascular Imaging, 2024, 40 : 769 - 778
  • [6] Point-of-care device for the noninvasive assessment of hepatic macrosteatosis in liver donors
    Rajamani, Allwyn S.
    Rammohan, Ashwin
    Shamlee, Kuzhandai J.
    Hakeem, Abdul R.
    Sai, V. V. Raghavendra
    Vij, Mukul
    Rela, Mohamed
    JOURNAL OF GASTROINTESTINAL SURGERY, 2024, 28 (06) : 799 - 804
  • [7] Myocardial Extracellular Volume Quantification by Cardiovascular Magnetic Resonance and Computed Tomography
    Paul R. Scully
    Gorka Bastarrika
    James C. Moon
    Thomas A. Treibel
    Current Cardiology Reports, 2018, 20
  • [8] Myocardial Extracellular Volume Quantification by Cardiovascular Magnetic Resonance and Computed Tomography
    Scully, Paul R.
    Bastarrika, Gorka
    Moon, James C.
    Treibel, Thomas A.
    CURRENT CARDIOLOGY REPORTS, 2018, 20 (03)
  • [9] Extracellular volume quantification by cardiac magnetic resonance imaging without hematocrit samplingReady for prime time?
    Andreas A. Kammerlander
    Franz Duca
    Christina Binder
    Stefan Aschauer
    Caroline Zotter-Tufaro
    Matthias Koschutnik
    Beatrice A. Marzluf
    Diana Bonderman
    Julia Mascherbauer
    Wiener klinische Wochenschrift, 2018, 130 : 190 - 196
  • [10] Extracellular volume quantification by cardiac magnetic resonance imaging without hematocrit sampling Ready for prime time?
    Kammerlander, Andreas A.
    Duca, Franz
    Binder, Christina
    Aschauer, Stefan
    Zotter-Tufaro, Caroline
    Koschutnik, Matthias
    Marzluf, Beatrice A.
    Bonderman, Diana
    Mascherbauer, Julia
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 (5-6) : 190 - 196