Electrochemical determination of picoxystrobin on boron-doped diamond electrode: Square-wave voltammetry versus BIA-multiple pulse amperometry

被引:20
|
作者
Dornellas, Rafael. M. [1 ,2 ]
Munoz, Rodrigo A. A. [2 ]
Aucelio, Ricardo Q. [1 ]
机构
[1] Pontific Catholic Univ Rio de Janeiro PUC Rio, Dept Chem, BR-22451900 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38408100 Uberlandia, MG, Brazil
关键词
Strobilurin; Batch-injection analysis; Multiple-pulse amperometry; Natural water; BATCH INJECTION-ANALYSIS; STROBILURIN FUNGICIDES; LIQUID-CHROMATOGRAPHY; ANALYSIS SYSTEM; FLOW; MICROEXTRACTION; TIME;
D O I
10.1016/j.microc.2015.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reports and compares the performance of two new electrochemical methods for the determination of picoxystrobin (a strobilurin-class fungicide). The methods were square-wave voltammetry (SWV) and batch-injection analysis (BIA) with multiple-pulse amperometric detection, both employing boron-doped diamond (BDD) electrode, which was cathodically treated to enhance the electrochemical activity for picoxystrobin. The SWV method presented higher sensitivity with lower detection (LOD of 0.2 mu mol L-1 or 0.07 mg L-1) and quantification limits (LOQ of 0.7 mu mol L-1 or 0.25 mg L-1) in comparison with the BIA amperometric method CLOD of 1.6 mu mol L-1 or 0.6 mg L-1 and LOQ of 5.3 mu mol L-1 or 2.0 mg L-1). However, the BIA-amperometric method provided wider linear range (from 5.3 to 100.0 mu mol L-1) in comparison with the SWV method (from 0.7 to 20.0 mu mol L-1) and higher analytical frequency rate (108 measurements h(-1)). Interference of other strobilurin compounds was evaluated and the presence of trifluoxystrobin and fluoxystrobin (up to 3-fold excess) affected the SWV determination of picoxystrobin. The amperometric method undergoes interference from the all of the tested strobilurins but a simple approach, based on multiple-pulse amperometry, can indicate the presence of some of the potential interfering species. Hence, either SWV or BIA-multiple pulse amperometry can be applied for picoxystrobin depending on analyte concentration, presence of interfering species, and required analytical frequency. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [41] COMPARISON OF BORON-DOPED DIAMOND AND GLASSY CARBON ELECTRODES FOR DETERMINATION OF TERBINAFINE IN PHARMACEUTICALS USING DIFFERENTIAL PULSE AND SQUARE WAVE VOLTAMMETRY
    Mielech-Lukasiewicz, Katarzyna
    Dabrowska, Agnieszka
    ANALYTICAL LETTERS, 2014, 47 (10) : 1697 - 1711
  • [42] Determination of Cd2+ by ultrasound-assisted square wave anodic stripping voltammetry with a boron-doped diamond electrode
    Zhang, Tianjin
    Li, Chongying
    Mao, Benjiang
    An, Yan
    IONICS, 2015, 21 (06) : 1761 - 1769
  • [43] Determination of Cd2+ by ultrasound-assisted square wave anodic stripping voltammetry with a boron-doped diamond electrode
    Tianjin Zhang
    Chongying Li
    Benjiang Mao
    Yan An
    Ionics, 2015, 21 : 1761 - 1769
  • [44] Square-wave voltammetric determination of hydroxychloroquine in pharmaceutical and synthetic urine samples using a cathodically pretreated boron-doped diamond electrode
    Deroco, Patricia Batista
    Vicentini, Fernando Campanha
    Oliveira, Geiser Gabriel
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 719 : 19 - 23
  • [45] Electrochemical determination of bisphenol A using a boron-doped diamond electrode
    Pereira, Gabriel F.
    Andrade, Leonardo S.
    Rocha-Filho, Romeu C.
    Bocchi, Nerilso
    Biaggio, Sonia R.
    ELECTROCHIMICA ACTA, 2012, 82 : 3 - 8
  • [46] Sensitive square-wave voltammetric determination of tadalafil (Cialis®) in pharmaceutical samples using a cathodically pretreated boron-doped diamond electrode
    Sartori, Elen Romao
    Clausen, Debora Nobile
    Ruiz Pires, Igor Matheus
    Rossi Salamanca-Neto, Carlos Alberto
    DIAMOND AND RELATED MATERIALS, 2017, 77 : 153 - 158
  • [47] ELECTROCHEMICAL DETERMINATION OF DICLOFENAC USING BORON-DOPED DIAMOND ELECTRODE
    Ihos, M.
    Remes, A.
    Manea, F.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2012, 13 (04): : 2096 - 2103
  • [48] Determination of Nitrophenols in Drinking and River Water by Differential Pulse Voltammetry at Boron-Doped Diamond Film Electrode
    Musilova, Jana
    Barek, Jiri
    Peckova, Karolina
    ELECTROANALYSIS, 2011, 23 (05) : 1236 - 1244
  • [49] Determination of Propylthiouracil in Pharmaceuticals by Differential Pulse Voltammetry Using a Cathodically Pretreated Boron-Doped Diamond Electrode
    Sartori, Elen Romao
    Trench, Aline Barrios
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (09) : 1504 - 1511
  • [50] Determination of Copper and Iron in Real Sample of Water and Ethanol Using Square Wave Voltammetry with a Micro/Nano Boron-Doped Diamond Electrode
    Ibernom, A. C. S.
    Ferreira, N. G.
    Braga, N. A.
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2022, 25