Electrochemical determination of picoxystrobin on boron-doped diamond electrode: Square-wave voltammetry versus BIA-multiple pulse amperometry

被引:20
|
作者
Dornellas, Rafael. M. [1 ,2 ]
Munoz, Rodrigo A. A. [2 ]
Aucelio, Ricardo Q. [1 ]
机构
[1] Pontific Catholic Univ Rio de Janeiro PUC Rio, Dept Chem, BR-22451900 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38408100 Uberlandia, MG, Brazil
关键词
Strobilurin; Batch-injection analysis; Multiple-pulse amperometry; Natural water; BATCH INJECTION-ANALYSIS; STROBILURIN FUNGICIDES; LIQUID-CHROMATOGRAPHY; ANALYSIS SYSTEM; FLOW; MICROEXTRACTION; TIME;
D O I
10.1016/j.microc.2015.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reports and compares the performance of two new electrochemical methods for the determination of picoxystrobin (a strobilurin-class fungicide). The methods were square-wave voltammetry (SWV) and batch-injection analysis (BIA) with multiple-pulse amperometric detection, both employing boron-doped diamond (BDD) electrode, which was cathodically treated to enhance the electrochemical activity for picoxystrobin. The SWV method presented higher sensitivity with lower detection (LOD of 0.2 mu mol L-1 or 0.07 mg L-1) and quantification limits (LOQ of 0.7 mu mol L-1 or 0.25 mg L-1) in comparison with the BIA amperometric method CLOD of 1.6 mu mol L-1 or 0.6 mg L-1 and LOQ of 5.3 mu mol L-1 or 2.0 mg L-1). However, the BIA-amperometric method provided wider linear range (from 5.3 to 100.0 mu mol L-1) in comparison with the SWV method (from 0.7 to 20.0 mu mol L-1) and higher analytical frequency rate (108 measurements h(-1)). Interference of other strobilurin compounds was evaluated and the presence of trifluoxystrobin and fluoxystrobin (up to 3-fold excess) affected the SWV determination of picoxystrobin. The amperometric method undergoes interference from the all of the tested strobilurins but a simple approach, based on multiple-pulse amperometry, can indicate the presence of some of the potential interfering species. Hence, either SWV or BIA-multiple pulse amperometry can be applied for picoxystrobin depending on analyte concentration, presence of interfering species, and required analytical frequency. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [21] Square-wave voltammetric determination of propranolol and atenolol in pharmaceuticals using a boron-doped diamond electrode
    Sartori, Elen Romao
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2010, 81 (4-5) : 1418 - 1424
  • [22] Electrochemical behavior of the cotinine at a boron-doped diamond electrode and its determination in saliva by multiple-pulse amperometry in an FIA system
    Alecrim, Morgana F.
    Oliveira, Fernando M.
    Guedes, Tiago J.
    Neves, Camila D. C.
    Mendonca, Vanessa A.
    Gil, Eric S.
    Verly, Rodrigo M.
    dos Santos, Wallans T. P.
    ELECTROCHIMICA ACTA, 2016, 222 : 331 - 337
  • [23] Electrochemical determination of pterostilbene at a cathodically pretreated boron-doped diamond electrode using square-wave adsorptive anodic stripping voltammetry in cationic surfactant media
    Yigit, Aydin
    Yardim, Yavuz
    Zorer, Ozlem Selcuk
    Senturk, Zuhre
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 231 : 688 - 695
  • [24] Square-Wave Voltammetric Determination of Antihistaminic Drug Hydroxyzine in Pharmaceuticals Using a Boron-doped Diamond Electrode
    Scremin, Jessica
    Sartori, Elen Romao
    ORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY, 2016, 8 (03): : 174 - 180
  • [25] A SIMPLE SQUARE-WAVE VOLTAMMETRIC METHOD FOR THE DETERMINATION OF SCOPOLAMINE IN PHARMACEUTICALS USING A BORON-DOPED DIAMOND ELECTRODE
    Santos, Simone Birkheur
    Valezi, Camila Farinha
    Scremin, Jessica
    Rossi Salamanca-Neto, Carlos Alberto
    Dall'Antonia, Luiz Henrique
    Sartori, Elen Romao
    QUIMICA NOVA, 2014, 37 (10): : 1579 - 1583
  • [26] A Novel Strategy for Quantifying Clopidogrel Using Square-wave Voltammetry and a Boron-doped Diamond Film
    Nascimento, Louise Oliveira
    Scremin, Jessica
    Mattos, Gabriel Junquetti
    Gomes, Adriana
    Clausen, Debora Nobile
    Sartori, Elen Romao
    ELECTROANALYSIS, 2020, 32 (01) : 191 - 197
  • [27] Determination of Terbinafine at a Boron-Doped Diamond (BDD) Electrode Modified with Polypyrrole and γ-Cyclodextrin by Square Wave Voltammetry (SWV)
    Mielech-Lukasiewicz, Katarzyna
    ANALYTICAL LETTERS, 2023, 56 (14) : 2275 - 2290
  • [28] Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode
    Ardila, Jorge Armando
    Sartori, Elen Romao
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2013, 103 : 201 - 206
  • [29] Determination of methiocarb pesticide using differential pulse voltammetry with a boron-doped diamond electrode
    Chylkova, J.
    Tomaskova, M.
    Svancara, I.
    Janikova, L.
    Selesovska, R.
    ANALYTICAL METHODS, 2015, 7 (11) : 4671 - 4677
  • [30] Individual and simultaneous electroanalytical sensing of epinephrine and lidocaine using an anodically pretreated boron-doped diamond electrode by square-wave voltammetry
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuhre
    DIAMOND AND RELATED MATERIALS, 2020, 101