Electrochemical determination of picoxystrobin on boron-doped diamond electrode: Square-wave voltammetry versus BIA-multiple pulse amperometry

被引:20
|
作者
Dornellas, Rafael. M. [1 ,2 ]
Munoz, Rodrigo A. A. [2 ]
Aucelio, Ricardo Q. [1 ]
机构
[1] Pontific Catholic Univ Rio de Janeiro PUC Rio, Dept Chem, BR-22451900 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38408100 Uberlandia, MG, Brazil
关键词
Strobilurin; Batch-injection analysis; Multiple-pulse amperometry; Natural water; BATCH INJECTION-ANALYSIS; STROBILURIN FUNGICIDES; LIQUID-CHROMATOGRAPHY; ANALYSIS SYSTEM; FLOW; MICROEXTRACTION; TIME;
D O I
10.1016/j.microc.2015.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reports and compares the performance of two new electrochemical methods for the determination of picoxystrobin (a strobilurin-class fungicide). The methods were square-wave voltammetry (SWV) and batch-injection analysis (BIA) with multiple-pulse amperometric detection, both employing boron-doped diamond (BDD) electrode, which was cathodically treated to enhance the electrochemical activity for picoxystrobin. The SWV method presented higher sensitivity with lower detection (LOD of 0.2 mu mol L-1 or 0.07 mg L-1) and quantification limits (LOQ of 0.7 mu mol L-1 or 0.25 mg L-1) in comparison with the BIA amperometric method CLOD of 1.6 mu mol L-1 or 0.6 mg L-1 and LOQ of 5.3 mu mol L-1 or 2.0 mg L-1). However, the BIA-amperometric method provided wider linear range (from 5.3 to 100.0 mu mol L-1) in comparison with the SWV method (from 0.7 to 20.0 mu mol L-1) and higher analytical frequency rate (108 measurements h(-1)). Interference of other strobilurin compounds was evaluated and the presence of trifluoxystrobin and fluoxystrobin (up to 3-fold excess) affected the SWV determination of picoxystrobin. The amperometric method undergoes interference from the all of the tested strobilurins but a simple approach, based on multiple-pulse amperometry, can indicate the presence of some of the potential interfering species. Hence, either SWV or BIA-multiple pulse amperometry can be applied for picoxystrobin depending on analyte concentration, presence of interfering species, and required analytical frequency. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Application of a deconvolutive procedure to analyze several chlorophenol species in natural waters by square-wave voltammetry on the boron-doped diamond electrode
    Pedrosa, Valber A.
    Machado, Sergio A. S.
    Avaca, Luis A.
    ANALYTICAL LETTERS, 2006, 39 (09) : 1955 - 1965
  • [32] Lead detection using micro/nanocrystalline boron-doped diamond by square-wave anodic stripping voltammetry
    Arantes, Tatiane M.
    Sardinha, Andre
    Baldan, Mauricio R.
    Cristovan, Fernando H.
    Ferreira, Neidenei G.
    TALANTA, 2014, 128 : 132 - 140
  • [33] Square wave voltammetry on boron-doped diamond electrodes for analytical determinations
    Codognoto, L
    Machado, SAS
    Avaca, LA
    DIAMOND AND RELATED MATERIALS, 2002, 11 (09) : 1670 - 1675
  • [34] Electroanalytical determination of promethazine hydrochloride in pharmaceutical formulations on highly boron-doped diamond electrodes using square-wave adsorptive voltammetry
    Ribeiro, Francisco Wirley P.
    Cardoso, Amanda S.
    Portela, Rafael R.
    Lima, Janete E. S.
    Machado, Sergio A. S.
    de Lima-Neto, Pedro
    De Souza, Djenaine
    Correia, Adriana N.
    ELECTROANALYSIS, 2008, 20 (18) : 2031 - 2039
  • [35] Boron-doped diamond electrode: a modification-free platform for sensitive square-wave voltammetric determination of indapamide hydrochloride
    Rossi Salamanca-Neto, Carlos Alberto
    Yoshida, Fabiana Ayumi
    Sartori, Elen Romao
    Moraes, Jaqueline Tobias
    ANALYTICAL METHODS, 2018, 10 (27) : 3347 - 3352
  • [36] Electroanalytical determination of 4-chlorophenol by square wave voltammetry on Boron-doped diamond electrodes
    Pedrosa, VD
    Codognoto, L
    Avaca, LA
    QUIMICA NOVA, 2003, 26 (06): : 844 - 849
  • [37] ELECTROCHEMICAL DETERMINATION OF NOREPINEPHRINE BY ADSORPTIVE STRIPPING VOLTAMMETRY USING A BARE BORON-DOPED DIAMOND ELECTRODE
    Keskin, Ertugrul
    Yardim, Yavuz
    Levent, Abdulkadir
    Senturk, Zuhre
    REVUE ROUMAINE DE CHIMIE, 2019, 64 (12) : 1063 - 1072
  • [38] Quantification of ferulic acid using square-wave voltammetric method at an unmodified boron-doped diamond electrode
    Pinar, Pinar Talay
    Barzani, Hemn A. H.
    Ali, Hoshyar Saadi
    Yardim, Yavuz
    MONATSHEFTE FUR CHEMIE, 2023, 154 (11): : 1225 - 1233
  • [39] Quantification of ferulic acid using square-wave voltammetric method at an unmodified boron-doped diamond electrode
    Pınar Talay Pınar
    Hemn A. H. Barzani
    Hoshyar Saadi Ali
    Yavuz Yardım
    Monatshefte für Chemie - Chemical Monthly, 2023, 154 : 1225 - 1233
  • [40] Determination of manganese in particulate matter of workplace environments using a boron-doped diamond electrode and cathodic stripping square wave voltammetry
    Felix, Fabiana da Silva
    Mendes de Barros, Rita de Cassia
    Lichtig, Jaim
    Masini, Jorge C.
    Ferreira, Neidenei Gomes
    QUIMICA NOVA, 2005, 28 (06): : 1000 - 1005