Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [41] Determination of residues of UV filters in natural waters by solid-phase extraction coupled to liquid chromatography-photodiode array detection and gas chromatography-mass spectrometry
    Giokas, DL
    Sakkas, VA
    Albanis, TA
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1026 (1-2) : 289 - 293
  • [42] Online solid-phase extraction–liquid chromatography–electrospray–tandem mass spectrometry determination of multiple classes of antibiotics in environmental and treated waters
    Venkata R. Panditi
    Sudha Rani Batchu
    Piero R. Gardinali
    Analytical and Bioanalytical Chemistry, 2013, 405 : 5953 - 5964
  • [43] Ultra-high performance liquid chromatography tandem mass spectrometry for the determination of five glycopeptide antibiotics in food and biological samples using solid-phase extraction
    Deng, Fenfang
    Yu, Hong
    Pan, Xinhong
    Hu, Guoyuan
    Wang, Qiqin
    Peng, Rongfei
    Tan, Lei
    Yang, Zhicong
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1538 : 54 - 59
  • [44] Simultaneous determination of 22 antibiotics in environmental water samples by solid phase extraction. high performance liquid chromatography.tandem mass spectrometry
    Wang Jin
    Ye Kaixiao
    Tian Yan
    Liu Ke
    Liang Liuling
    Li Qingqian
    Huang Ning
    Wang Xinting
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (03) : 241 - 249
  • [45] Determination of eumelanin and pheomelanin in melanomas using solid-phase extraction and high performance liquid chromatography-diode array detection (HPLC-DAD) analysis
    Rioux, Benjamin
    Rouanet, Jacques
    Akil, Hussein
    Besse, Sophie
    Debiton, Eric
    Bouchon, Bernadette
    Degoul, Francoise
    Quintana, Mercedes
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1113 : 60 - 68
  • [46] Determination of three sweeteners in vinegars by solid phase extraction-high performance liquid chromatography/tandem mass spectrometry
    Yin Feng
    Ding Zhaowei
    Cao Xue
    Gao Jie
    Jiang Deming
    Kuang Denghui
    Gu Yanping
    He Guoliang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 554 - 557
  • [48] Determination of Alkaloids in Honey by Dispersive Solid Phase Extraction and High Performance Liquid Chromatography-Tandem Mass Spectrometry
    Guo Wei-Hua
    Zhou Jin-Hui
    Huang Jing-Ping
    Wang Peng
    Li Yi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (10) : 1453 - 1458
  • [49] Determination of Siderophores in Seawater by High Performance Liquid Chromatography-Tandem Mass Spectrometry Coupled with Solid Phase Extraction
    Zhang Lei
    Yuan Dong-Xing
    Fang Kai
    Liu Bao-Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1285 - 1290
  • [50] Determination of glycolaldehyde, glyceraldehydes in plasma by solid phase extraction-high performance liquid chromatography-mass spectrometry
    Dong Lulu
    Li Zewen
    Li Baoxin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (07) : 1015 - 1018