Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [21] Determination of porphyrins and metalloporphyrins using liquid chromatography-diode array detection and mass spectrometry
    Magi, E
    Ianni, C
    Rivaro, P
    Frache, R
    JOURNAL OF CHROMATOGRAPHY A, 2001, 905 (1-2) : 141 - 149
  • [22] Determination of methotrexate in environmental samples by solid phase extraction and high performance liquid chromatography: ultraviolet or tandem mass spectrometry detection?
    Turci, R
    Micoli, G
    Minoia, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (08) : 685 - 691
  • [23] Determination of sulfadiazine in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with a diode-array detector
    Lian, Ziru
    He, Xingliang
    Wang, Jiangtao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 : 53 - 59
  • [24] Dispersive solid-phase extraction followed by high-performance liquid chromatography/tandem mass spectrometry for the determination of ricinine in cooking oil
    Cai, Meiqiang
    Chen, Xiaohong
    Wei, Xiaoqing
    Pan, Shengdong
    Zhao, Yonggang
    Jin, Micong
    FOOD CHEMISTRY, 2014, 158 : 459 - 465
  • [25] Automated solid-phase extraction for sample preparation followed by high-performance liquid chromatography with diode array and mass spectrometric detection for the analysis of resveratrol derivatives in wine
    Domínguez, C
    Guillén, DA
    Barroso, CG
    JOURNAL OF CHROMATOGRAPHY A, 2001, 918 (02) : 303 - 310
  • [26] Determination of fluoroquinolone antibiotics in wastewater by solid-phase extraction high performance liquid chromatography with fluorescence detection
    He, Ke
    Blaney, Lee
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [27] Simultaneous Detection of Sulfamethoxazole, Diclofenac, Carbamazepine, and Bezafibrate by Solid Phase Extraction and High Performance Liquid Chromatography with Diode Array Detection
    Zhou, Z.
    Jiang, J. -Q.
    JOURNAL OF APPLIED SPECTROSCOPY, 2014, 81 (02) : 273 - 278
  • [28] Simultaneous Detection of Sulfamethoxazole, Diclofenac, Carbamazepine, and Bezafibrate by Solid Phase Extraction and High Performance Liquid Chromatography with Diode Array Detection
    Z. Zhou
    J.-Q. Jiang
    Journal of Applied Spectroscopy, 2014, 81 : 273 - 278
  • [29] Simultaneous Determination of Residual Antibiotics in Livestock Manure by Solid Phase Extraction-Ultra-high Performance Liquid Chromatography Tantem Mass Spectrometry
    Wan Wei-Ning
    Chen Xi
    Ju Xue-Hai
    Mu Quan-Hua
    Wang Chong
    Mao Da-Qing
    Luo Yi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (07) : 993 - 999
  • [30] Selective and rapid determination of tadalafil and finasteride using solid phase extraction by high performance liquid chromatography and tandem mass spectrometry
    Nagaraju, Pappula
    Kodali, Balaji
    Datla, Peda Varma
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 152 : 215 - 223