Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [31] Determination of alkylphenol and alkylphenolpolyethoxylates in brine by solid phase extraction and high performance liquid chromatography-mass spectrometry
    Wang Jincheng
    Xiong Li
    Zhang Haijun
    Chen Jiping
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (12) : 1160 - 1164
  • [32] Determination of the Biocide Econea® in Artificial Seawater by Solid Phase Extraction and High Performance Liquid Chromatography Mass Spectrometry
    Downs, Robert A.
    Dean, John R.
    Downer, Adrian
    Perry, Justin J.
    SEPARATIONS, 2017, 4 (04)
  • [33] Simultaneous Determination of Squalene, α-Tocopherol and β-Carotene in Table Olives by Solid Phase Extraction and High-Performance Liquid Chromatography with Diode Array Detection
    Sagratini, Gianni
    Allegrini, Marco
    Caprioli, Giovanni
    Cristalli, Gloria
    Giardina, Dario
    Maggi, Filippo
    Ricciutelli, Massimo
    Sirocchi, Veronica
    Vittori, Sauro
    FOOD ANALYTICAL METHODS, 2013, 6 (01) : 54 - 60
  • [34] Simultaneous Determination of Squalene, α-Tocopherol and β-Carotene in Table Olives by Solid Phase Extraction and High-Performance Liquid Chromatography with Diode Array Detection
    Gianni Sagratini
    Marco Allegrini
    Giovanni Caprioli
    Gloria Cristalli
    Dario Giardina
    Filippo Maggi
    Massimo Ricciutelli
    Veronica Sirocchi
    Sauro Vittori
    Food Analytical Methods, 2013, 6 : 54 - 60
  • [35] Determination of polyphenols in beer by an effective method based on solid-phase extraction and high performance liquid chromatography with diode-array detection
    Dvorakova, Marketa
    Hulin, Petr
    Karabin, Marcel
    Dostalek, Pavel
    CZECH JOURNAL OF FOOD SCIENCES, 2007, 25 (04) : 182 - 188
  • [36] Determination of squalene using high-performance liquid chromatography with diode array detection
    Lu, HT
    Jiang, Y
    Chen, F
    CHROMATOGRAPHIA, 2004, 59 (5-6) : 367 - 371
  • [37] Determination of Squalene Using High-Performance Liquid Chromatography with Diode Array Detection
    Hai-Tao Lu
    Yue Jiang
    Feng Chen
    Chromatographia, 2004, 59 : 367 - 371
  • [38] APPLICATION OF ONLINE SOLID-PHASE EXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-THERMOSPRAY MASS-SPECTROMETRY TO THE DETERMINATION OF PESTICIDES IN ENVIRONMENTAL WATERS
    CHIRON, S
    DUPAS, S
    SCRIBE, P
    BARCELO, D
    JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (02) : 295 - 305
  • [39] Determination of estrogens and their conjugates in water using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry
    Isobe, T
    Shiraishi, H
    Yasuda, M
    Shinoda, A
    Suzuki, H
    Morita, M
    JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) : 195 - 202
  • [40] Determination of Thirteen Antibiotics Residues in Manure by Solid Phase Extraction and High Performance Liquid Chromatography
    Hu Xian-Gang
    Luo Yi
    Zhou Qi-Xing
    Xu Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (09) : 1162 - 1166