Determination of some frequently used antibiotics in waste waters using solid phase extraction followed by high performance liquid chromatography with diode array and mass spectrometry detection

被引:55
|
作者
Opris, Ocsana [1 ]
Soran, Maria-Loredana [1 ]
Coman, Virginia [2 ]
Copaciu, Florina [2 ]
Ristoiu, Dumitru [3 ]
机构
[1] Natl Inst Res & Dev Isotop & Mol Technol, Cluj Napoca 400293, Romania
[2] Univ Babes Bolyai, Raluca Ripan Inst Res Chem, Cluj Napoca 400294, Romania
[3] Univ Babes Bolyai, Fac Environm Sci & Engn, Cluj Napoca 400294, Romania
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 08期
关键词
Antibiotics; Waste waters; Solid-phase extraction; High performance liquid chromatography; Mass spectrometry; BETA-LACTAM ANTIBIOTICS; RELIABLE QUANTIFICATION; MACROLIDE ANTIBIOTICS; ENVIRONMENTAL WATERS; MULTIPLE CLASSES; TREATMENT-PLANT; SURFACE-WATER; WASTEWATERS; PHARMACEUTICALS; CONTAMINATION;
D O I
10.2478/s11532-013-0263-y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study is focused on the determination of some important antibiotics from different classes in waste water samples using solid phase extraction followed by high performance liquid chromatography with two detectors, diode array and mass spectrometer in positive ionisation mode. The investigated antibiotics include three penicillins (amoxicillin, ampicillin, penicillin G), two cephalosporins (ceftazidime, ceftriaxone), and two tetracyclines (tetracycline, doxycycline). The studied antibiotics were extracted from waste water samples using hydrophilic-lipophilic balanced cartridges. The extraction of antibiotics from water matrices was tested at several pH values. The best recoveries were obtained at pH 3 and 7 respectively. Depending on the nature of antibiotic, the limits of detection and quantification were obtained in the range of 0.07-0.92 A mu g mL(-1) and 0.21-2.77 A mu g mL(-1) respectively. Influent and effluent waste water samples were collected from a Waste Water Treatment Plant from Romania in order to detect the studied antibiotics. The antibiotics detected in the influent waste water samples were ceftriaxone (334 A mu g L-1), tetracycline (146 A mu g L-1) and doxycycline (110 A mu g L-1). In effluent waste water samples no target antibiotics were detected.
引用
收藏
页码:1343 / 1351
页数:9
相关论文
共 50 条
  • [1] Determination of Antibiotics in Surface Water by Solid-Phase Extraction and High-Performance Liquid Chromatography with Diode Array and Mass Spectrometry Detection
    Soran, Maria-Loredana
    Lung, Ildiko
    Opris, Ocsana
    Floare-Avram, Veronica
    Coman, Cristian
    ANALYTICAL LETTERS, 2017, 50 (07) : 1209 - 1218
  • [2] DETERMINATION OF LOTUS LEAF ALKALOIDS BY SOLID PHASE EXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE ARRAY AND TANDEM MASS SPECTROMETRY DETECTION
    Chen, Sha
    Zhang, Haohao
    Liu, Yanling
    Fang, Jinbao
    Li, Shaohua
    ANALYTICAL LETTERS, 2013, 46 (18) : 2846 - 2859
  • [3] Pesticide Residue Determination in Groundwater using Solid-Phase Extraction and High-Performance Liquid Chromatography with Diode Array Detector and Liquid Chromatography-Tandem Mass Spectrometry
    Caldas, Sergiane S.
    Demoliner, Adriana
    Costa, Fabiane P.
    D'Oca, Marcelo G. M.
    Primel, Ednei G.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (04) : 642 - 650
  • [4] Determination of organophosphorus pesticides and metabolites in crops by solid-phase extraction followed by liquid chromatography diode array detection
    Lagana, A
    DAscenzo, G
    Fago, G
    Marino, A
    CHROMATOGRAPHIA, 1997, 46 (5-6) : 256 - 264
  • [5] Determination of organophosphorus pesticides and metabolites in crops by solid-phase extraction followed by liquid chromatography/Diode array detection
    A. Laganà
    G. D'Ascenzo
    G. Fago
    A. Marino
    Chromatographia, 1997, 46 : 256 - 264
  • [6] Determination of organophosphorus pesticides and metabolites in crops by solid-phase extraction followed by liquid chromatography/diode array detection
    Department of Chemistry, La Sapienza, P.le Aldo Moro 5, 00185 Rome, Italy
    CHROMATOGRAPHIA, 5-6 (256-264):
  • [7] Matrix effects in determination of triazines and atrazine metabolite in waters with solid-phase extraction followed by high performance liquid chromatography coupled with tandem mass spectrometry
    Kovacic, N
    Zupancic-Kralj, L
    ANALYTICAL LETTERS, 2006, 39 (01) : 207 - 220
  • [8] Solid-phase extraction followed by liquid chromatography-mass spectrometry for trace determination of β-lactam antibiotics in bovine milk
    Bruno, F
    Curini, R
    Di Corcia, A
    Nazzari, M
    Samperi, R
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (07) : 3463 - 3470
  • [9] Determination of antibiotics in aquatic environment by solid-phase extraction followed by liquid chromatography-electrospray ionization mass spectrometry
    Rao, R. Nageswara
    Venkateswarlu, N.
    Narsimha, R.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1187 (1-2) : 151 - 164
  • [10] Determination of isoxaflutole (balance) and its metabolites in water using solid phase extraction followed by high-performance liquid chromatography with ultraviolet or mass spectrometry
    Lin, CH
    Lerch, RN
    Thurman, EM
    Garrett, HE
    George, MF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (21) : 5816 - 5824