Label-free impedimetric thrombin sensor based on poly(pyrrole-nitrilotriacetic acid)-aptamer film

被引:60
|
作者
Xu, Hui [1 ,2 ]
Gorgy, Karine [1 ]
Gondran, Chantal [1 ]
Le Goff, Alan [1 ]
Spinelli, Nicolas [1 ]
Lopez, Christian [3 ]
Defrancq, Eric [1 ]
Cosnier, Serge [1 ]
机构
[1] Univ Grenoble 1, CNRS, Dept Chim Mol, ICMG FR 2607,UMR 5250, F-38041 Grenoble 9, France
[2] Ludong Univ, Sch Chem & Mat Sci, Yantai 264025, Peoples R China
[3] Univ Grenoble 1, UMR CNRS 5279, Grenoble INP, Lab Electrochim & Physicochim Mat & Interfaces, F-38402 St Martin Dheres, France
来源
关键词
Thrombin; Impedance spectroscopy; Aptasensor; Polypyrrole; Biosensor; SURFACE-PLASMON RESONANCE; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; PROTEIN-DETECTION; IMPEDANCE SPECTROSCOPY; APTAMER BIOSENSORS; CARBON NANOTUBES; APTASENSOR; ELECTROCHEMILUMINESCENCE; ELECTROGENERATION;
D O I
10.1016/j.bios.2012.07.044
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free and highly sensitive impedimetric aptasensor was developed based on electropolymerized film for the determination of thrombin. The first step is the electrogeneration of a poly(pyrrole-nitrilotriacetic acid) (poly(pyrrole-NTA)) film onto the surface of electrodes followed by complexation of Cu2+ ions. Then, the histidine labeled thrombin aptamer was immobilized onto the electrode through coordination of the histidine groups on the NTA-Cu2+ complex. The aptamer sensor was applied for the detection and quantification of thrombin via impedimetric detection without a labeling step. A linear quantification of thrombin was obtained in the range 4.7 x 10(-12)-5.0 x 10(-10) mol L-1 with a sensitivity of 2838 Omega/log unit (R-2=0.9984). The impedance modulus at 0.3 Hz as a function of thrombin concentration was used to elaborate a similar linear relationship from 4.7 x 10(-12) to 5 x 10(-10) mol L-1. In addition, aptamer-poly(pyrrole-NTA) electrodes incubated for 40 min in aqueous solutions of bovine serum albumin (BSA), lysozyme and IgG (5 x 10(-7) mol L-1) did not exhibit nonspecific adsorption of proteins. Moreover, it has been demonstrated that the selective sensor can be regenerated several times with a good reproducibility. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [41] Impedimetric Immunosensor Based on a Polypyrrole-Antibiotic Model Film for the Label-Free Picomolar Detection of Ciprofloxacin
    Giroud, Fabien
    Gorgy, Karine
    Gondran, Chantal
    Cosnier, Serge
    Pinacho, Daniel G.
    Marco, M. -Pilar
    Sanchez-Baeza, Francisco J.
    ANALYTICAL CHEMISTRY, 2009, 81 (20) : 8405 - 8409
  • [42] A Rapid, Label-free and Impedimetric DNA Sensor Based on PNA-modified Nanoporous Gold Electrode
    Tao, Wenyan
    Lin, Peng
    Liu, Hong
    Ke, Shanming
    Zeng, Xierong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (11): : 10511 - 10523
  • [43] Modeling the microscopic electrical properties of thrombin binding aptamer (TBA) for label-free biosensors
    Alfinito, Eleonora
    Reggiani, Lino
    Cataldo, Rosella
    De Nunzio, Giorgio
    Giotta, Livia
    Guascito, Maria Rachele
    NANOTECHNOLOGY, 2017, 28 (06)
  • [44] An impedimetric microelectrode-based array sensor for label-free detection of tau hyperphosphorylation in human cells
    Jahnke, Heinz-Georg
    Rothermel, Andree
    Sternberger, Ina
    Mack, Till G. A.
    Kurz, Randy G.
    Paenke, Oliver
    Striggow, Frank
    Robitzki, Andrea A.
    LAB ON A CHIP, 2009, 9 (10) : 1422 - 1428
  • [45] Label-free aptamer biosensor for thrombin detection on a nanocomposite of graphene and plasma polymerized allylamine
    Zhang, Zhihong
    Liu, Shunli
    Shi, Yu
    Zhang, Yuanchang
    Peacock, Dave
    Yan, Fufeng
    Wang, Peiyuan
    He, Linghao
    Feng, Xiaozhong
    Fang, Shaoming
    JOURNAL OF MATERIALS CHEMISTRY B, 2014, 2 (11) : 1530 - 1538
  • [46] Label-free aptamer sensor for 17β-estradiol based on vanadium disulfide nanoflowers and Au nanoparticles
    Huang, Ke-Jing
    Liu, Yu-Jie
    Shi, Gang-Wei
    Yang, Xue-Rui
    Liu, Yan-Ming
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 201 : 579 - 585
  • [47] Electrochemical sensor for detecting streptomycin in milk based on label-free aptamer chain and magnetic adsorption
    Wang, Li
    Wang, Hongsu
    Huang, Shuqing
    Wu, Fengling
    Niu, Xiaodi
    FOOD CHEMISTRY, 2023, 403
  • [48] A simple and label-free fluorescent DNA sensor for visual detection of aptamer-based berberine
    Zhang, Wenjuan
    Luo, Mingwan
    Chen, Juan
    Li, Zhengxing
    Wei, Xian
    Wu, Miqi
    Yang, Shengli
    He, Yuanju
    Wang, Xiaoping
    Xiao, Zhiyou
    ANALYTICAL METHODS, 2024, 16 (42) : 7130 - 7138
  • [49] A label-free RTP sensor based on aptamer/quantum dot nanocomposites for cytochrome c detection
    Li, Dongxia
    Guo, Junping
    Zhao, Liang
    Zhang, Guoxian
    Yan, Guiqin
    RSC ADVANCES, 2019, 9 (55) : 31953 - 31959
  • [50] A molecular light switch Ru complex and quantum dots for the label-free, aptamer-based detection of thrombin
    Sun, Wenliang
    Yao, Tianming
    Shi, Shuo
    ANALYST, 2012, 137 (07) : 1550 - 1552