Label-free impedimetric thrombin sensor based on poly(pyrrole-nitrilotriacetic acid)-aptamer film

被引:60
|
作者
Xu, Hui [1 ,2 ]
Gorgy, Karine [1 ]
Gondran, Chantal [1 ]
Le Goff, Alan [1 ]
Spinelli, Nicolas [1 ]
Lopez, Christian [3 ]
Defrancq, Eric [1 ]
Cosnier, Serge [1 ]
机构
[1] Univ Grenoble 1, CNRS, Dept Chim Mol, ICMG FR 2607,UMR 5250, F-38041 Grenoble 9, France
[2] Ludong Univ, Sch Chem & Mat Sci, Yantai 264025, Peoples R China
[3] Univ Grenoble 1, UMR CNRS 5279, Grenoble INP, Lab Electrochim & Physicochim Mat & Interfaces, F-38402 St Martin Dheres, France
来源
关键词
Thrombin; Impedance spectroscopy; Aptasensor; Polypyrrole; Biosensor; SURFACE-PLASMON RESONANCE; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; PROTEIN-DETECTION; IMPEDANCE SPECTROSCOPY; APTAMER BIOSENSORS; CARBON NANOTUBES; APTASENSOR; ELECTROCHEMILUMINESCENCE; ELECTROGENERATION;
D O I
10.1016/j.bios.2012.07.044
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free and highly sensitive impedimetric aptasensor was developed based on electropolymerized film for the determination of thrombin. The first step is the electrogeneration of a poly(pyrrole-nitrilotriacetic acid) (poly(pyrrole-NTA)) film onto the surface of electrodes followed by complexation of Cu2+ ions. Then, the histidine labeled thrombin aptamer was immobilized onto the electrode through coordination of the histidine groups on the NTA-Cu2+ complex. The aptamer sensor was applied for the detection and quantification of thrombin via impedimetric detection without a labeling step. A linear quantification of thrombin was obtained in the range 4.7 x 10(-12)-5.0 x 10(-10) mol L-1 with a sensitivity of 2838 Omega/log unit (R-2=0.9984). The impedance modulus at 0.3 Hz as a function of thrombin concentration was used to elaborate a similar linear relationship from 4.7 x 10(-12) to 5 x 10(-10) mol L-1. In addition, aptamer-poly(pyrrole-NTA) electrodes incubated for 40 min in aqueous solutions of bovine serum albumin (BSA), lysozyme and IgG (5 x 10(-7) mol L-1) did not exhibit nonspecific adsorption of proteins. Moreover, it has been demonstrated that the selective sensor can be regenerated several times with a good reproducibility. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [31] Label-free peptide aptamer based impedimetric biosensor for highly sensitive detection of TNT with a ternary assembly layer
    Li, Yanyan
    Zhao, Manru
    Wang, Haiyan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (27) : 6371 - 6377
  • [32] Detection for folding of the thrombin binding aptamer using label-free electrochemical methods
    Cho, Minseon
    Kim, Yeonwha
    Han, Se-Young
    Min, Kyungin
    Rahman, Aminur
    Shim, Yoon-Bo
    Ban, Changill
    BMB REPORTS, 2008, 41 (02) : 126 - 131
  • [33] Development of a novel label-free impedimetric electrochemical sensor based on hydrogel/chitosan for the detection of ochratoxin A
    Li, Xiaoyan
    Falcone, Natashya
    Hossain, M. Nur
    Kraatz, Heinz-Bernhard
    Chen, Xiaojun
    Huang, He
    TALANTA, 2021, 226
  • [34] A sensitive and label-free impedimetric biosensor based on an adjunct probe
    Zhang, Xi Yuan
    Zhou, Long Yin
    Luo, Hong Qun
    Li, Nian Bing
    ANALYTICA CHIMICA ACTA, 2013, 776 : 11 - 16
  • [35] Development of an impedimetric sensor for the label-free detection of the amino acid sarcosine with molecularly imprinted polymer receptors
    Tin Phan Nguy
    Toan Van Phi
    Tram, Do T. N.
    Eersels, Kasper
    Wagner, Patrick
    Lien, Truong T. N.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 : 461 - 470
  • [36] Aptamer-Based Electrochemical Sensor for Label-Free Recognition and Detection of Cancer Cells
    Pan, Chunfeng
    Guo, Manli
    Nie, Zhou
    Xiao, Xilin
    Yao, Shouzhuo
    ELECTROANALYSIS, 2009, 21 (11) : 1321 - 1326
  • [37] Label-free detection of kanamycin using aptamer-based cantilever array sensor
    Bai, Xiaojing
    Hou, Hui
    Zhang, Bailin
    Tang, Jilin
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 112 - 116
  • [38] Label-free DNA sensor based on organic thin film transistors
    Yan, Feng
    Mok, Sheung Man
    Yu, Jinjiang
    Chan, Helen L. W.
    Yang, Mo
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1241 - 1245
  • [39] Impedimetric Microfluidic Sensor-in-a-Tube for Label-Free Immune Cell Analysis
    Egunov, Aleksandr, I
    Dou, Zehua
    Karnaushenko, Dmitriy D.
    Hebenstreit, Franziska
    Kretschmann, Nicole
    Akgun, Katja
    Ziemssen, Tjalf
    Karnaushenko, Daniil
    Medina-Sanchez, Mariana
    Schmidt, Oliver G.
    SMALL, 2021, 17 (05)
  • [40] Multiple Nonenzymatic Labels-Based Impedimetric Aptamer Sensor for the Competitive Detection of Thrombin
    Jeong, Bongjin
    Akter, Rashida
    Han, Oe Hee
    Rhee, Choong Kyun
    Rahman, Md Aminur
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (03): : 721 - 722