Label-free impedimetric thrombin sensor based on poly(pyrrole-nitrilotriacetic acid)-aptamer film

被引:60
|
作者
Xu, Hui [1 ,2 ]
Gorgy, Karine [1 ]
Gondran, Chantal [1 ]
Le Goff, Alan [1 ]
Spinelli, Nicolas [1 ]
Lopez, Christian [3 ]
Defrancq, Eric [1 ]
Cosnier, Serge [1 ]
机构
[1] Univ Grenoble 1, CNRS, Dept Chim Mol, ICMG FR 2607,UMR 5250, F-38041 Grenoble 9, France
[2] Ludong Univ, Sch Chem & Mat Sci, Yantai 264025, Peoples R China
[3] Univ Grenoble 1, UMR CNRS 5279, Grenoble INP, Lab Electrochim & Physicochim Mat & Interfaces, F-38402 St Martin Dheres, France
来源
关键词
Thrombin; Impedance spectroscopy; Aptasensor; Polypyrrole; Biosensor; SURFACE-PLASMON RESONANCE; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; PROTEIN-DETECTION; IMPEDANCE SPECTROSCOPY; APTAMER BIOSENSORS; CARBON NANOTUBES; APTASENSOR; ELECTROCHEMILUMINESCENCE; ELECTROGENERATION;
D O I
10.1016/j.bios.2012.07.044
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free and highly sensitive impedimetric aptasensor was developed based on electropolymerized film for the determination of thrombin. The first step is the electrogeneration of a poly(pyrrole-nitrilotriacetic acid) (poly(pyrrole-NTA)) film onto the surface of electrodes followed by complexation of Cu2+ ions. Then, the histidine labeled thrombin aptamer was immobilized onto the electrode through coordination of the histidine groups on the NTA-Cu2+ complex. The aptamer sensor was applied for the detection and quantification of thrombin via impedimetric detection without a labeling step. A linear quantification of thrombin was obtained in the range 4.7 x 10(-12)-5.0 x 10(-10) mol L-1 with a sensitivity of 2838 Omega/log unit (R-2=0.9984). The impedance modulus at 0.3 Hz as a function of thrombin concentration was used to elaborate a similar linear relationship from 4.7 x 10(-12) to 5 x 10(-10) mol L-1. In addition, aptamer-poly(pyrrole-NTA) electrodes incubated for 40 min in aqueous solutions of bovine serum albumin (BSA), lysozyme and IgG (5 x 10(-7) mol L-1) did not exhibit nonspecific adsorption of proteins. Moreover, it has been demonstrated that the selective sensor can be regenerated several times with a good reproducibility. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 95
页数:6
相关论文
共 50 条
  • [21] Aptamer biosensor for label-free impedance spectroscopy detection of thrombin based on gold nanoparticles
    Li, Li-Dong
    Zhao, Hong-Tao
    Chen, Zheng-Bo
    Mu, Xiao-Jiao
    Guo, Lin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01): : 189 - 194
  • [22] Label-free and sensitive thrombin sensing on a molecularly grafted aptamer on graphene
    Wang, Yanping
    Xiao, Yinghong
    Ma, Xiaoling
    Lia, Na
    Yang, Xiaodi
    CHEMICAL COMMUNICATIONS, 2012, 48 (05) : 738 - 740
  • [23] Graphene based electrodes for label-free impedimetric biosensing
    Siaj, Mohamed
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [24] Label-Free Fluorescent Aptamer Sensor Based on Regulation of Malachite Green Fluorescence
    Xu, Weichen
    Lu, Yi
    ANALYTICAL CHEMISTRY, 2010, 82 (02) : 574 - 578
  • [25] A label-free fluorescent aptamer sensor for testosterone based on SYBR Green I
    Hou, Yucui
    Lu, Xiaoling
    Yang, Jie
    Tang, Chunhua
    Jiang, Hanbing
    Cai, Tongji
    Chen, Meilun
    Wei, Zheng
    Yu, Peng
    ANALYTICAL METHODS, 2023, 15 (12) : 1546 - 1552
  • [26] Label-free fluorescent sensor based on aptamer and thiazole orange for the detection of tetracycline
    Sun, Chunyan
    Su, Ruifang
    Bie, Jiaxin
    Sun, Hongjing
    Qiao, Shangna
    Ma, Xinyue
    Sun, Rui
    Zhang, Tiehua
    DYES AND PIGMENTS, 2018, 149 : 867 - 875
  • [27] Quantitative Label-Free Listeria Analysis Based On Aptamer Modified Nanoporous Sensor
    Zhou, Chun-Xia
    Mo, Ri-Jian
    Chen, Zhi-Meng
    Wang, Juan
    Shen, Guo-Zhu
    Li, Yi-Ping
    Quan, Qin-Guo
    Liu, Ying
    Li, Cheng-Yong
    ACS SENSORS, 2016, 1 (08): : 965 - 969
  • [28] A label-free and high sensitive aptamer biosensor based on hyperbranched polyester microspheres for thrombin detection
    Sun, Chong
    Han, Qiaorong
    Wang, Daoying
    Xu, Weimin
    Wang, Weijuan
    Zhao, Wenbo
    Zhou, Min
    ANALYTICA CHIMICA ACTA, 2014, 850 : 33 - 40
  • [29] Label-free Aptamer Biosensor with Poly(thionine) as an Electrochemical Probe
    Yang Shao-Ming
    Zha Wen-Ling
    Li Hong
    Sun Qing
    Liu Bin
    Zheng Long-Zhen
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2013, 34 (03): : 551 - 555
  • [30] Label-free peptide aptamer based impedimetric biosensor for highly sensitive detection of TNT with a ternary assembly layer
    Yanyan Li
    Manru Zhao
    Haiyan Wang
    Analytical and Bioanalytical Chemistry, 2017, 409 : 6371 - 6377