Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry

被引:11
|
作者
Ganeev, A. A. [1 ]
Gubal, A. R. [1 ]
Potapov, S. V. [2 ]
Pogarev, S. E. [1 ]
Sholupov, S. E. [1 ]
Uskov, K. N. [1 ]
Ivanov, I. S. [1 ]
机构
[1] St Petersburg State Univ, Fac Chem, St Petersburg 198504, Russia
[2] Lumass Ltd, St Petersburg 192029, Russia
关键词
time-of-flight mass-spectrometry; pulsed glow discharge; HOLLOW-CATHODE; SAMPLES; NUCLEAR;
D O I
10.1134/S1061934813140050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of water in the discharge cell is a serious problem in glow discharge mass spectrometry. Even very small quantities of water can make considerable changes in the composition and electrical parameters of the plasma, which lead to a decrease in the signal intensity and the appearance of various cluster components. This results in a very complicated mass spectrum and significantly deteriorates the analytical performance of the method. Different approaches to solving the this problem are discussed in the paper. A multiple position interface that allows analyzing 6-10 samples without decapsulation of the discharge cell is presented in this work. It is also shown that the use of a tantalum auxiliary cathode ensures a several-order depression of the interfering components (OH+, OH (2) (+) , OH (3) (+) , (CH)-C-12-H-1 (2) (+) , O-16(+), (CH)-C-12-H-1 (3) (+) ) because of its getter behavior. The simultaneous application of all proposed approaches ensures solving the problem of interferences in the combined hollow cathode with pulsed glow discharge to the great extent.
引用
收藏
页码:1205 / 1211
页数:7
相关论文
共 50 条
  • [31] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Auristela Solà-Vázquez
    José M. Costa-Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2771 - 2777
  • [32] Evaluation of pulsed radiofrequency glow discharge time-of-flight mass spectrometry for precious metal determination in lead fire assay buttons
    Compernolle, Sien
    Pisonero, Jorge
    Bordel, Nerea
    Wambeke, Dorine
    De Raedt, Ine
    Kimpe, Kristof
    Sanz-Medel, Alfredo
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 129 - 133
  • [33] Direct FexOy speciation in solid state materials by pulsed millisecond radio frequency glow discharge time-of-flight mass spectrometry
    Gu, Guodong
    DeJesus, Megan
    King, Fred L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (04) : 816 - 821
  • [34] Tunable fragmentation of organic molecules in laser ablation glow discharge time-of-flight mass spectrometry
    Lotito, G.
    Guenther, D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (08) : 2565 - 2576
  • [35] Spectroscopic evaluation of a compact magnetically boosted radiofrequency glow discharge for time-of-flight mass spectrometry
    Vega, P.
    Pisonero, J.
    Bordel, N.
    Tempez, A.
    Ganciu, M.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) : 373 - 382
  • [36] Spectroscopic evaluation of a compact magnetically boosted radiofrequency glow discharge for time-of-flight mass spectrometry
    P. Vega
    J. Pisonero
    N. Bordel
    A. Tempez
    M. Ganciu
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2009, 394 : 373 - 382
  • [37] Tunable fragmentation of organic molecules in laser ablation glow discharge time-of-flight mass spectrometry
    G. Lotito
    D. Günther
    Analytical and Bioanalytical Chemistry, 2012, 402 : 2565 - 2576
  • [38] Suppression of gas species signals in direct current glow discharge time-of-flight mass spectrometry
    Su, YX
    Yang, PY
    Zhou, Z
    Li, FM
    Wang, XR
    Huang, BL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) : 1271 - 1275
  • [39] Comparison of characteristics of microsecond-pulse glow discharge and direct current glow discharge as ion sources for time-of-flight mass spectrometry
    Su, Yongxuan
    Yang, Pengyuan
    Zhou, Zhen
    Li, Fumin
    Wang, Xiaoru
    Huang, Benli
    Dianxin Kexue/Telecommunications Science, 14 (05): : 14 - 18
  • [40] Consideration of a millisecond pulsed glow discharge time-of-flight mass spectrometer for concurrent elemental and molecular analysis
    Steiner, RE
    Lewis, CL
    Majidi, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1537 - 1541