Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry

被引:11
|
作者
Ganeev, A. A. [1 ]
Gubal, A. R. [1 ]
Potapov, S. V. [2 ]
Pogarev, S. E. [1 ]
Sholupov, S. E. [1 ]
Uskov, K. N. [1 ]
Ivanov, I. S. [1 ]
机构
[1] St Petersburg State Univ, Fac Chem, St Petersburg 198504, Russia
[2] Lumass Ltd, St Petersburg 192029, Russia
关键词
time-of-flight mass-spectrometry; pulsed glow discharge; HOLLOW-CATHODE; SAMPLES; NUCLEAR;
D O I
10.1134/S1061934813140050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of water in the discharge cell is a serious problem in glow discharge mass spectrometry. Even very small quantities of water can make considerable changes in the composition and electrical parameters of the plasma, which lead to a decrease in the signal intensity and the appearance of various cluster components. This results in a very complicated mass spectrum and significantly deteriorates the analytical performance of the method. Different approaches to solving the this problem are discussed in the paper. A multiple position interface that allows analyzing 6-10 samples without decapsulation of the discharge cell is presented in this work. It is also shown that the use of a tantalum auxiliary cathode ensures a several-order depression of the interfering components (OH+, OH (2) (+) , OH (3) (+) , (CH)-C-12-H-1 (2) (+) , O-16(+), (CH)-C-12-H-1 (3) (+) ) because of its getter behavior. The simultaneous application of all proposed approaches ensures solving the problem of interferences in the combined hollow cathode with pulsed glow discharge to the great extent.
引用
收藏
页码:1205 / 1211
页数:7
相关论文
共 50 条
  • [21] Direct Quantification of Major and Trace Elements in Geological Samples by Time-of-Flight Mass Spectrometry with a Pulsed Glow Discharge
    Ganeev, Aleksander
    Titova, Anna
    Korotetski, Boris
    Gubal, Anna
    Solovyev, Nikolay
    Vyacheslavov, Alexander
    Iakovleva, Evgenia
    Sillanpaa, Mika
    ANALYTICAL LETTERS, 2019, 52 (04) : 671 - 684
  • [22] Direct manganese (Mn) speciation in solid state materials by pulsed glow discharge time-of-flight mass spectrometry
    Zhang, Na
    King, Fred L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1489 - 1497
  • [23] A comparison of non-pulsed radiofrequency and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes
    Lobo, L.
    Pisonero, J.
    Bordel, N.
    Pereiro, R.
    Tempez, A.
    Chapon, P.
    Michler, J.
    Hohl, M.
    Sanz-Medel, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1373 - 1381
  • [24] Influence of discharge parameters on real-time chemical speciation for gas chromatography pulsed glow discharge plasma time-of-flight mass spectrometry
    Lewis, CL
    Moser, MA
    Hang, W
    Dale, DE
    Hassell, DC
    Majidi, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (06) : 629 - 636
  • [25] Pulsed radiofrequency glow discharge time-of-flight mass spectrometry for molecular depth profiling of polymer-based films
    Tuccitto, Nunzio
    Lobo, Lara
    Tempez, Agnes
    Delfanti, Ivan
    Chapon, Patrick
    Canulescu, Stela
    Bordel, Nerea
    Michler, Johann
    Licciardello, Antonino
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (05) : 549 - 556
  • [26] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    20151900828891
    Fernández, Beatriz (fernandezbeatriz@uniovi.es), 1600, Royal Society of Chemistry (30):
  • [27] Quantitative depth profile analysis of boron implanted silicon by pulsed radiofrequency glow discharge time-of-flight mass spectrometry
    Pisonero, J.
    Lobo, L.
    Bordel, N.
    Tempez, A.
    Bensaoula, A.
    Badi, N.
    Sanz-Medel, A.
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2010, 94 (08) : 1352 - 1357
  • [28] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    Bouza, Marcos
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (05) : 1108 - 1116
  • [29] RF-pulsed glow discharge time-of-flight mass spectrometry for glass analysis: Investigation of the ion source design
    Bouza, Marcos
    Fernandez, Beatriz
    Gonzalez-Gago, Cristina
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICA CHIMICA ACTA, 2012, 756 : 30 - 36
  • [30] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Sola-Vazquez, Auristela
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (09) : 2771 - 2777