Tunable fragmentation of organic molecules in laser ablation glow discharge time-of-flight mass spectrometry

被引:0
|
作者
G. Lotito
D. Günther
机构
[1] Laboratory of Inorganic Chemistry,
来源
关键词
Pulsed glow discharge; MALDI; Laser ablation; Fragmentation; Chemical speciation;
D O I
暂无
中图分类号
学科分类号
摘要
A DC-pulsed glow discharge (GD) has distinct temporal regimes which are characterized by “softer” or “harder” ionization of analytes introduced into the discharge. It is thus possible to obtain both molecular weight and structural fragment information from the same spectra. In order to extend the capabilities of this technique a laser ablation (LA) sampling system was coupled to a DC-pulsed GD and to a time-of-flight (TOF) mass spectrometer (MS) for characterizing organic samples such as oleic acid, reserpine, two different peptides, and a polymer. Both hard and soft ionization regimes were studied. These LAGD-TOFMS results were compared to matrix-assisted laser desorption ionization (MALDI) spectra using the same compounds (i.e., analytes, concentration, and matrix). It was found that LAGD offers tunable ionization and provides a reduced matrix dependence. However, the sensitivity achieved by the prototype LAGD-TOFMS was significantly lower when compared with commercially available MALDI-TOFMS instrumentation. Since LAGD-TOFMS is rather new, some technical details to increase its sensitivity are discussed.
引用
收藏
页码:2565 / 2576
页数:11
相关论文
共 50 条
  • [1] Tunable fragmentation of organic molecules in laser ablation glow discharge time-of-flight mass spectrometry
    Lotito, G.
    Guenther, D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (08) : 2565 - 2576
  • [2] Negative ion laser ablation glow discharge-time of flight mass spectrometry of organic molecules
    Lotito, G.
    Guenther, D.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 315 : 60 - 65
  • [3] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [4] Development and fundamental investigation of Laser Ablation Glow Discharge Time-Of-Flight Mass Spectrometry (LA-GD-TOFMS)
    Tarik, Mohamed
    Lotito, Giovanni
    Whitby, James A.
    Koch, Joachim
    Fuhrer, Katrin
    Gonin, Marc
    Michler, Johann
    Bolli, Jean-Luc
    Guenther, Detlef
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (03) : 262 - 270
  • [5] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    Lobo, L.
    Tuccitto, N.
    Bordel, N.
    Pereiro, R.
    Pisonero, J.
    Licciardello, A.
    Tempez, A.
    Chapon, P.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2863 - 2869
  • [6] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    L. Lobo
    N. Tuccitto
    N. Bordel
    R. Pereiro
    J. Pisonero
    A. Licciardello
    A. Tempez
    P. Chapon
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2863 - 2869
  • [7] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [8] Gas chromatography coupled to tunable pulsed glow discharge time-of-flight mass spectrometry for environmental analysis
    Sola-Vazquez, Auristela
    Lara-Gonzalo, Azucena
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYST, 2010, 135 (05) : 987 - 993
  • [9] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, DM
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (12) : 1326 - 1331
  • [10] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, Denise M.
    Hieftje, Gary M.
    Journal of Analytical Atomic Spectrometry, 2005, 20 (12): : 1326 - 1331