Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer

被引:14
|
作者
McClenathan, DM [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1039/b513823j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several absolute quantitation strategies have been evaluated for multielemental analysis in glow discharge mass spectrometry. A method for standardless analysis is described that offers accuracy within all order of magnitude. without relying on any calibration factors or internal standards, However, the accuracy Of this method can be improved by two- to four-fold through use of relative sensitivity factors (RSFs), These factors, determined from a global set of standards that included iron, nickel. cobalt. and copper matrices. were fairly independent of the matrix. Similar results were obtained using RSFs from the global set. RSFs from standards with a similar matrix, and RSFs from a single standard. When RSFs were employed, experimental results were determined with a mean accuracy of 5 12% for analyte concentrations greater than 1%.
引用
收藏
页码:1326 / 1331
页数:6
相关论文
共 50 条
  • [1] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, Denise M.
    Hieftje, Gary M.
    Journal of Analytical Atomic Spectrometry, 2005, 20 (12): : 1326 - 1331
  • [2] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [3] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    L. Lobo
    N. Tuccitto
    N. Bordel
    R. Pereiro
    J. Pisonero
    A. Licciardello
    A. Tempez
    P. Chapon
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2863 - 2869
  • [4] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [5] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    Lobo, L.
    Tuccitto, N.
    Bordel, N.
    Pereiro, R.
    Pisonero, J.
    Licciardello, A.
    Tempez, A.
    Chapon, P.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2863 - 2869
  • [6] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    A. A. Ganeev
    A. R. Gubal
    S. V. Potapov
    S. E. Pogarev
    S. E. Sholupov
    K. N. Uskov
    I. S. Ivanov
    Journal of Analytical Chemistry, 2013, 68 : 1205 - 1211
  • [7] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    Ganeev, A. A.
    Gubal, A. R.
    Potapov, S. V.
    Pogarev, S. E.
    Sholupov, S. E.
    Uskov, K. N.
    Ivanov, I. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (14) : 1205 - 1211
  • [8] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [9] Quantitation of irbesartan and major proteins in human plasma by mass spectrometry with time-of-flight analyzer
    Lu, Chi-Yu
    Feng, Chia-Hsien
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 100 - 105
  • [10] Microsecond-pulsed glow discharge time-of-flight mass spectrometry: Analytical advantages
    Hang, W
    Baker, C
    Smith, BW
    Winefordner, JD
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) : 143 - 149