Microsecond-pulsed glow discharge time-of-flight mass spectrometry: Analytical advantages

被引:49
|
作者
Hang, W
Baker, C
Smith, BW
Winefordner, JD
Harrison, WW
机构
[1] Department of Chemistry, University of Florida, Gainesville
关键词
glow discharge; pulsed glow discharge; time-of-flight mass spectrometry; atomic mass spectrometry;
D O I
10.1039/a604454i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microsecond-pulsed glow discharge time-of-flight mass spectrometer was constructed and evaluated for elemental analysis. Mass spectra from the instrument show significant advantages, including higher signal-to-noise ratios than those of a de glow discharge source. Important temporal advantages result from the pulsed discharge and pulsed mass analyser. Mass discrimination among different elements is very small. The instrument currently has a resolving power of 360 in linear mode and 1600 in reflectron mode (full width at half maximum). Present detection limits are at the low ppm level, limited primarily by the detection and data acquisition system. Because the detector is easily saturated, the present data acquisition system has limited dynamic range and sensitivity. Possibilities exist to overcome this constraint.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 50 条
  • [1] Microsecond-pulsed Grimm glow discharge as a source for time-of-flight mass spectrometry
    Yang, CL
    Mohill, M
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) : 1255 - 1260
  • [2] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [3] MICROSECOND PULSED GLOW-DISCHARGE TIME-OF-FLIGHT MASS-SPECTROMETER
    HANG, W
    YANG, PY
    WANG, XR
    YANG, CL
    SU, YX
    HUANG, BL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) : 590 - 594
  • [4] Microsecond pulsed versus direct current glow discharge as ion sources for analytical glow discharge-time of flight mass spectrometry
    Martín, Antonio
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Journal of Analytical Atomic Spectrometry, 2007, 22 (09): : 1179 - 1183
  • [5] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [6] Tuneable Microsecond-Pulsed Glow Discharge Design for the Simultaneous Acquisition of Elemental and Molecular Chemical Information Using a Time-of-Flight Mass Spectrometer
    Sola-Vazquez, Auristela
    Martin, Antonio
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL CHEMISTRY, 2009, 81 (07) : 2591 - 2599
  • [7] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    A. A. Ganeev
    A. R. Gubal
    S. V. Potapov
    S. E. Pogarev
    S. E. Sholupov
    K. N. Uskov
    I. S. Ivanov
    Journal of Analytical Chemistry, 2013, 68 : 1205 - 1211
  • [8] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    Ganeev, A. A.
    Gubal, A. R.
    Potapov, S. V.
    Pogarev, S. E.
    Sholupov, S. E.
    Uskov, K. N.
    Ivanov, I. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (14) : 1205 - 1211
  • [9] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [10] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Sola-Vazquez, Auristela
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (09) : 2771 - 2777