Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer

被引:0
|
作者
McClenathan, Denise M. [1 ]
Hieftje, Gary M. [1 ]
机构
[1] Department of Chemistry, Indiana University, Bloomington, IN 47405, United States
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
10
引用
收藏
页码:1326 / 1331
相关论文
共 50 条
  • [1] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, DM
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (12) : 1326 - 1331
  • [2] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [3] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    L. Lobo
    N. Tuccitto
    N. Bordel
    R. Pereiro
    J. Pisonero
    A. Licciardello
    A. Tempez
    P. Chapon
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2863 - 2869
  • [4] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [5] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    Lobo, L.
    Tuccitto, N.
    Bordel, N.
    Pereiro, R.
    Pisonero, J.
    Licciardello, A.
    Tempez, A.
    Chapon, P.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2863 - 2869
  • [6] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    A. A. Ganeev
    A. R. Gubal
    S. V. Potapov
    S. E. Pogarev
    S. E. Sholupov
    K. N. Uskov
    I. S. Ivanov
    Journal of Analytical Chemistry, 2013, 68 : 1205 - 1211
  • [7] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    Ganeev, A. A.
    Gubal, A. R.
    Potapov, S. V.
    Pogarev, S. E.
    Sholupov, S. E.
    Uskov, K. N.
    Ivanov, I. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (14) : 1205 - 1211
  • [8] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [9] Quantitation of irbesartan and major proteins in human plasma by mass spectrometry with time-of-flight analyzer
    Lu, Chi-Yu
    Feng, Chia-Hsien
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 100 - 105
  • [10] Microsecond-pulsed glow discharge time-of-flight mass spectrometry: Analytical advantages
    Hang, W
    Baker, C
    Smith, BW
    Winefordner, JD
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) : 143 - 149