Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer

被引:14
|
作者
McClenathan, DM [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1039/b513823j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several absolute quantitation strategies have been evaluated for multielemental analysis in glow discharge mass spectrometry. A method for standardless analysis is described that offers accuracy within all order of magnitude. without relying on any calibration factors or internal standards, However, the accuracy Of this method can be improved by two- to four-fold through use of relative sensitivity factors (RSFs), These factors, determined from a global set of standards that included iron, nickel. cobalt. and copper matrices. were fairly independent of the matrix. Similar results were obtained using RSFs from the global set. RSFs from standards with a similar matrix, and RSFs from a single standard. When RSFs were employed, experimental results were determined with a mean accuracy of 5 12% for analyte concentrations greater than 1%.
引用
收藏
页码:1326 / 1331
页数:6
相关论文
共 50 条
  • [21] Tunable fragmentation of organic molecules in laser ablation glow discharge time-of-flight mass spectrometry
    G. Lotito
    D. Günther
    Analytical and Bioanalytical Chemistry, 2012, 402 : 2565 - 2576
  • [22] Suppression of gas species signals in direct current glow discharge time-of-flight mass spectrometry
    Su, YX
    Yang, PY
    Zhou, Z
    Li, FM
    Wang, XR
    Huang, BL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) : 1271 - 1275
  • [23] Time-of-flight mass spectrometry
    Vestal, ML
    SELECTED TOPICS IN MASS SPECTROMETRY IN THE BIOMOLECULAR SCIENCES, 1997, 504 : 239 - 262
  • [24] Time-of-flight mass spectrometry
    Busch, KL
    SPECTROSCOPY, 1997, 12 (04) : 22 - +
  • [25] TIME-OF-FLIGHT MASS SPECTROMETRY
    PRICE, D
    CHEMISTRY IN BRITAIN, 1968, 4 (06) : 255 - &
  • [26] Comparison of characteristics of microsecond-pulse glow discharge and direct current glow discharge as ion sources for time-of-flight mass spectrometry
    Su, Yongxuan
    Yang, Pengyuan
    Zhou, Zhen
    Li, Fumin
    Wang, Xiaoru
    Huang, Benli
    Dianxin Kexue/Telecommunications Science, 14 (05): : 14 - 18
  • [27] Determination of arsenic by hydride generation coupled to time-of-flight mass spectrometry with a gas sampling glow discharge
    Wetzel, WC
    Broekaert, JAC
    Hieftje, GM
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (06) : 1009 - 1023
  • [28] Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis
    Auristela Solà-Vázquez
    Beatriz Fernández
    José M. Costa-Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7431 - 7443
  • [29] Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis
    Sola-Vazquez, Auristela
    Fernandez, Beatriz
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7431 - 7443
  • [30] Direct isotope analysis of Chernobyl microparticles using time-of-flight mass spectrometry with pulsed glow discharge
    Ganeev, Aleksander
    Gubal, Anna
    Korotetski, Boris
    Bogdanova, Oksana
    Burakov, Boris
    Titova, Anna
    Solovyev, Nikolay
    Ivanenko, Natalya
    Drobyshev, Evgenii
    Iakovleva, Evgenia
    Sillanpaa, Mika
    MICROCHEMICAL JOURNAL, 2017, 132 : 286 - 292