Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans

被引:3
|
作者
Ceylan, Cemile [1 ,2 ]
Inal, Serpil Yondem [3 ]
Senol, Elif [3 ]
Yilmaz, Berrin [1 ]
Sahin, Sevim [4 ]
机构
[1] Istanbul Oncol Hosp, Radiat Oncol Dept, Istanbul, Turkey
[2] Yeditepe Univ, Hlth Sci Inst, Istanbul, Turkey
[3] Mem Bahcelievler Hosp, Radiat Oncol Dept, Istanbul, Turkey
[4] Fenerbahce Univ, Med Imaging Dept, Istanbul, Turkey
关键词
mlc error; patient-specific quality assurance; gamma-index evaluation; DYNAMIC IMRT; SLIDING WINDOW; MLC; ACCURACY; SENSITIVITY; PERFORMANCE; DELIVERY; CONSEQUENCES;
D O I
10.7759/cureus.12684
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The correlation between the MLC QA (IBA Dosimetry, Germany) results of the picket fence test created with intentional errors and the patient's quality assurance (QA) evaluation was investigated to assess the impact of multileaf collimator (MLC) positioning error on patient QA. Materials and methods The picket fence, including error-free and intentional MLC errors, defined in Bank In, Bank Out, and Bank Both were analyzed using MLC QA. The QA of 15 plans consisting of stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), and conventionally fractionated volumetric-modulated arc therapy (VMAT) acquired with electronic portal imaging devices (EPID) was evaluated in the presence of error-free and MLC errors. The QA of plans were analyzed with 2%/2 mm and 3%/3 mm criteria. Results The passing rates of the picket fence test were 97%, 92%, 91%, and 87% for error-free and intentional errors. The criterion of 3%/3 mm wasn't able to detect an MLC error for either SRS/SBRT or conventionally fractionated VMAT. The criterion of 2%/2mm was more sensitive to detect MLC error for the conventionally fractionated VMAT than SRS/SBRT. While only two of SBRT plans had <90%, four of conventionally fractionated VMAT plans had a <90% passing rate. Conclusion We found that the systematic MLC positioning errors defined with picket fence have a smaller but measurable impact on SRS/SBRT than the VMAT plan for a conventionally fractionated and relatively complex plan such as head and neck and endometrium cases.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Han, Ce
    Zhang, Ji
    Yu, Bing
    Zheng, Haoze
    Wu, Yibo
    Lin, Zhixi
    Ning, Boda
    Yi, Jinling
    Xie, Congying
    Jin, Xiance
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [32] Dosimetric Validation for Patient-specific Quality Assurance using the Delta44 Phantom with Volumetric Modulated Arc Therapy
    Arino Gil, A.
    Calvo, O.
    Gutierrez, A.
    Papanikolau, N.
    Hdez-Armas, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S717 - S717
  • [33] Integrating plan complexity and dosiomics features with deep learning in patient-specific quality assurance for volumetric modulated arc therapy
    Ce Han
    Ji Zhang
    Bing Yu
    Haoze Zheng
    Yibo Wu
    Zhixi Lin
    Boda Ning
    Jinling Yi
    Congying Xie
    Xiance Jin
    Radiation Oncology, 18
  • [34] Effect of the simulated half leaf width of a multileaf collimator on volumetric modulated arc therapy plan quality in hippocampal avoidance whole-brain radiotherapy
    Li, Ming-Hsien
    Chen, Li-Jhen
    Chang, Chih-Chieh
    Tsai, Jo-Ting
    Lin, Jang-Chun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [35] Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)
    Chen, X.
    Xing, L.
    Azcona, J.
    Luxton, G.
    Bush, K.
    MEDICAL PHYSICS, 2014, 41 (06) : 237 - 238
  • [36] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Yixiao Guo
    Jinyan Hu
    Yang Li
    Juntao Ran
    Hongyi Cai
    Scientific Reports, 13
  • [37] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Guo, Yixiao
    Hu, Jinyan
    Li, Yang
    Ran, Juntao
    Cai, Hongyi
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [38] Simplification of head and neck volumetric modulated arc therapy patient-specific quality assurance, using a Delta4 PT
    Sasaki, Motoharu
    Sugimoto, Wataru
    Ikushima, Hitoshi
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (05) : 793 - 800
  • [39] An Improved Statistical Model for Gamma Index Pass Rates in Intensity Modulated Radiation Therapy Patient-Specific Quality Assurance
    Jensen, P. James
    Donahue, William
    Chen, Zhe
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Prediction of patient-specific quality assurance for volumetric modulated arc therapy using radiomics-based machine learning with dose distribution
    Ishizaka, Natsuki
    Kinoshita, Tomotaka
    Sakai, Madoka
    Tanabe, Shunpei
    Nakano, Hisashi
    Tanabe, Satoshi
    Nakamura, Sae
    Mayumi, Kazuki
    Akamatsu, Shinya
    Nishikata, Takayuki
    Takizawa, Takeshi
    Yamada, Takumi
    Sakai, Hironori
    Kaidu, Motoki
    Sasamoto, Ryuta
    Ishikawa, Hiroyuki
    Utsunomiya, Satoru
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):