Exact reconstruction of volumetric images in reverse helical cone-beam CT

被引:21
|
作者
Cho, Seungryong [1 ,2 ]
Xia, Dan [1 ]
Pelizzari, Charles A. [2 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
cone-beam computed tomography; reconstruction; reverse helical; filtered backprojection; image-guided radiation therapy;
D O I
10.1118/1.2936219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Helical scanning configuration has been used widely in diagnostic cone-beam computed tomography (CBCT) for acquiring data sufficient for exact image reconstruction over an extended volume. In image-guided radiation therapy (IGRT) and other applications of CBCT, it can be difficult, if not impossible, to implement mechanically a multiple-turn helical trajectory on the imaging systems due to hardware constraints. However, imaging systems in these applications often allow for the implementation of a reverse helical trajectory in which the rotation direction changes between two consecutive turns. Because the reverse helical trajectory satisfies Tuy's condition, when projections of the imaged object are nontruncated, it yields data sufficient for exact image reconstruction within the reverse helix volume. The recently developed chord-based algorithms such as the backprojection filtration (BPF) algorithm can readily be applied to reconstructing images on chords of a reverse helical trajectory, and they can thus reconstruct an image within a volume covered by the chords. Conversely, the chord-based algorithms cannot reconstruct images within regions that are not intersected by chords. In a reverse helix volume, as shown below, chordless regions exist in which no images can thus be reconstructed by use of the chord-based algorithms. In this work, based upon Pack-Noo's formula, a shift-invariant filtered backprojection (FBP) algorithm is derived for exact image reconstruction within the reverse helix volume, including the chordless region. Numerical studies have also been conducted to demonstrate the chordless region in a reverse helix volume and to validate the FBP algorithm for image reconstruction within the chordless region. Results of the numerical studies confirm that the FBP algorithm can exactly reconstruct an image within the entire reverse helix volume, including the chordless region. It is relatively straightforward to extend the FBP algorithm to reconstruct images for general trajectories, including reverse helical trajectories with variable pitch, tilted axis, and/or additional segments between turns. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3030 / 3040
页数:11
相关论文
共 50 条
  • [41] Exact cone-beam CT reconstruction with general line-circle trajectories
    National Laboratory of Pattern Recognition, Institute of Automation, Chinese Academy of Sciences, Beijing 100080, China
    不详
    Tien Tzu Hsueh Pao, 2007, 7 (1382-1386):
  • [42] Cardiac cone-beam CT using a circle and line acquisition and an exact reconstruction
    Koken, Peter
    Bontus, Claas
    Koehler, Thomas
    Grass, Michael
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2355 - 2358
  • [43] A general exact reconstruction for cone-beam CT via backprojection-filtration
    Ye, YB
    Zhao, SY
    Yu, HY
    Wang, G
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (09) : 1190 - 1198
  • [44] The frequency split method for helical cone-beam reconstruction
    Shechter, G
    Köhler, T
    Altman, A
    Proksa, R
    MEDICAL PHYSICS, 2004, 31 (08) : 2230 - 2236
  • [45] Analysis of image noise with exact cone-beam reconstruction
    Lee, SW
    Wang, G
    RADIOLOGY, 2002, 225 : 253 - 253
  • [46] Quasi-exact region-of-interest reconstruction from helical cone-beam data
    Defrise, M
    Noo, F
    Kudo, H
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1101 - 1103
  • [47] A unified framework for exact cone-beam reconstruction formulas
    Zhao, SY
    Yu, HY
    Wang, G
    MEDICAL PHYSICS, 2005, 32 (06) : 1712 - 1721
  • [48] A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5497 - 5508
  • [49] A motion-compensated scheme for helical cone-beam reconstruction in cardiac CT angiography
    van Stevendaal, U.
    von Berg, J.
    Lorenz, C.
    Grass, M.
    MEDICAL PHYSICS, 2008, 35 (07) : 3239 - 3251
  • [50] Application of dual-energy techniques to helical, cone-beam CT image reconstruction
    Sidky, E
    Zou, Y
    Pan, X
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408