Exact reconstruction of volumetric images in reverse helical cone-beam CT

被引:21
|
作者
Cho, Seungryong [1 ,2 ]
Xia, Dan [1 ]
Pelizzari, Charles A. [2 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
cone-beam computed tomography; reconstruction; reverse helical; filtered backprojection; image-guided radiation therapy;
D O I
10.1118/1.2936219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Helical scanning configuration has been used widely in diagnostic cone-beam computed tomography (CBCT) for acquiring data sufficient for exact image reconstruction over an extended volume. In image-guided radiation therapy (IGRT) and other applications of CBCT, it can be difficult, if not impossible, to implement mechanically a multiple-turn helical trajectory on the imaging systems due to hardware constraints. However, imaging systems in these applications often allow for the implementation of a reverse helical trajectory in which the rotation direction changes between two consecutive turns. Because the reverse helical trajectory satisfies Tuy's condition, when projections of the imaged object are nontruncated, it yields data sufficient for exact image reconstruction within the reverse helix volume. The recently developed chord-based algorithms such as the backprojection filtration (BPF) algorithm can readily be applied to reconstructing images on chords of a reverse helical trajectory, and they can thus reconstruct an image within a volume covered by the chords. Conversely, the chord-based algorithms cannot reconstruct images within regions that are not intersected by chords. In a reverse helix volume, as shown below, chordless regions exist in which no images can thus be reconstructed by use of the chord-based algorithms. In this work, based upon Pack-Noo's formula, a shift-invariant filtered backprojection (FBP) algorithm is derived for exact image reconstruction within the reverse helix volume, including the chordless region. Numerical studies have also been conducted to demonstrate the chordless region in a reverse helix volume and to validate the FBP algorithm for image reconstruction within the chordless region. Results of the numerical studies confirm that the FBP algorithm can exactly reconstruct an image within the entire reverse helix volume, including the chordless region. It is relatively straightforward to extend the FBP algorithm to reconstruct images for general trajectories, including reverse helical trajectories with variable pitch, tilted axis, and/or additional segments between turns. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3030 / 3040
页数:11
相关论文
共 50 条
  • [21] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [22] Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06): : 941 - 959
  • [23] Exact image reconstruction from n-PI acquisition data in helical cone-beam CT
    Zou, Y
    Pan, XC
    Sidky, E
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2048 - 2052
  • [24] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135
  • [25] Artifact analysis of approximate helical cone-beam CT reconstruction algorithms
    Köhler, T
    Proksa, R
    Bontus, C
    Grass, M
    Timmer, J
    MEDICAL PHYSICS, 2002, 29 (01) : 51 - 64
  • [26] Tilted helical Feldkamp cone-beam reconstruction algorithm for multislice CT
    Hein, IA
    Taguchi, K
    Mori, I
    Kazama, M
    Silver, MD
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1901 - 1910
  • [27] Katsevich-type reconstruction for dual helical cone-beam CT
    Zeng, Li
    Zou, Xiaobing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (04) : 353 - 367
  • [28] A reconstruction algorithm for triple-source helical cone-beam CT
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1875 - 1878
  • [29] Sparse sampling in helical cone-beam CT perfect reconstruction algorithms
    Bendory, Tamir
    Feuer, Arie
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (03) : 389 - 405
  • [30] Quasi-exact helical cone beam reconstruction for micro CT
    Hu, JC
    Johnson, R
    Molthen, R
    Haworth, S
    Dawson, C
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 681 - 684