Exact reconstruction of volumetric images in reverse helical cone-beam CT

被引:21
|
作者
Cho, Seungryong [1 ,2 ]
Xia, Dan [1 ]
Pelizzari, Charles A. [2 ]
Pan, Xiaochuan [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
cone-beam computed tomography; reconstruction; reverse helical; filtered backprojection; image-guided radiation therapy;
D O I
10.1118/1.2936219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Helical scanning configuration has been used widely in diagnostic cone-beam computed tomography (CBCT) for acquiring data sufficient for exact image reconstruction over an extended volume. In image-guided radiation therapy (IGRT) and other applications of CBCT, it can be difficult, if not impossible, to implement mechanically a multiple-turn helical trajectory on the imaging systems due to hardware constraints. However, imaging systems in these applications often allow for the implementation of a reverse helical trajectory in which the rotation direction changes between two consecutive turns. Because the reverse helical trajectory satisfies Tuy's condition, when projections of the imaged object are nontruncated, it yields data sufficient for exact image reconstruction within the reverse helix volume. The recently developed chord-based algorithms such as the backprojection filtration (BPF) algorithm can readily be applied to reconstructing images on chords of a reverse helical trajectory, and they can thus reconstruct an image within a volume covered by the chords. Conversely, the chord-based algorithms cannot reconstruct images within regions that are not intersected by chords. In a reverse helix volume, as shown below, chordless regions exist in which no images can thus be reconstructed by use of the chord-based algorithms. In this work, based upon Pack-Noo's formula, a shift-invariant filtered backprojection (FBP) algorithm is derived for exact image reconstruction within the reverse helix volume, including the chordless region. Numerical studies have also been conducted to demonstrate the chordless region in a reverse helix volume and to validate the FBP algorithm for image reconstruction within the chordless region. Results of the numerical studies confirm that the FBP algorithm can exactly reconstruct an image within the entire reverse helix volume, including the chordless region. It is relatively straightforward to extend the FBP algorithm to reconstruct images for general trajectories, including reverse helical trajectories with variable pitch, tilted axis, and/or additional segments between turns. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3030 / 3040
页数:11
相关论文
共 50 条
  • [31] Exact FBP reconstruction for dynamic pitch helical cone beam CT
    Katsevich, A
    Basu, S
    Hsieh, J
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3299 - 3302
  • [32] Motion artefact reduction for exact cone-beam CT reconstruction algorithms
    Koken, P
    Köhler, T
    Bontus, C
    Proksa, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2985 - 2988
  • [33] A parallel backprojection algorithm for spiral cone-beam ct exact reconstruction
    Xue G.
    Zhang Y.
    International Journal of Digital Content Technology and its Applications, 2010, 4 (06) : 134 - 143
  • [34] Cone-beam CT with a modified reverse helical trajectory for long object problem
    Cho, Seungryong
    Xia, Dan
    Pelizzari, Charles A.
    Pan, Xiaochuam
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3518 - +
  • [35] An exact reconstruction algorithm in variable pitch helical cone-beam CT when PI-line exists
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Kang, Kejun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 109 - 118
  • [36] A RECONSTRUCTION ALGORITHM FOR HELICAL CONE-BEAM SPECT
    WENG, Y
    ZENG, GL
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1092 - 1101
  • [37] Sinogram Restoration in Helical Cone-Beam CT
    Little, K.
    La Riviere, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527
  • [38] Helical cone-beam CT for radiation therapy
    Yu, LF
    Pan, XC
    Pelizzari, CA
    Zou, Y
    Munro, P
    Riem, H
    Kaissl, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1890 - 1890
  • [39] Backprojection-filtration reconstruction for helical cone-beam CT with curved detectors
    Zuo, Nianming
    Xia, Dan
    Sidky, Emil Y.
    Yu, Lifeng
    Zou, Yu
    Pan, Xiaochuan
    Tang, Tianzi
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2306 - 2309
  • [40] Exact radon rebinning algorithm for the long object problem in helical cone-beam CT
    Schaller, S
    Noo, F
    Sauer, F
    Tam, KC
    Lauritsch, G
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 361 - 375