The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:26
|
作者
Standish, Christopher D. [1 ]
Chalk, Thomas B. [1 ]
Babila, Tali L. [1 ]
Milton, J. Andy [1 ]
Palmer, Martin R. [1 ]
Foster, Gavin L. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr Southampton, Sch Ocean & Earth Sci, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
关键词
PH; RATIOS; CARBONATES; ACCURATE; CORALS;
D O I
10.1002/rcm.8432
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Boron isotope analysis of marine carbonates by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) offers the potential for rapid sample throughput, and the means to examine micron-scale variations in the delta B-11 signatures of fossil skeletons and shells/tests of marine organisms. Existing studies demonstrate an acceptable level of reproducibility is achievable, but also typically show a level of accuracy outside the limits required by most applications. Here we investigate matrix interference effects as a cause of inaccuracy and imprecision. Methods Analyses were performed on a standard format Thermo Scientific Neptune Plus MC-ICP mass spectrometer coupled to a New Wave Research 193 nm ArF laser ablation system. The effects of matrix interference on delta B-11 analysis were investigated through analyses of a set of reference materials with differing B/Ca ratios. Three approaches to correct for matrix-induced effects were trialled: (1) use of matrix-matched standards, (2) utilisation of the relationship between delta B-11 inaccuracy and(11)B/Ca-43, B-11/(ArCa4+)-Ar-40 or B-11/Ca-interference from three reference materials with known delta B-11 values and varying B/Ca ratios, and (3) direct characterisation of the (sloping) interference itself. Results Matrix interference from scattered Ca ions on B-10 can impede both the accuracy and the reproducibility of delta B-11 analysis by LA-MC-ICP-MS. Based on analyses of two in-house reference materials, deep sea coral PS69/3181 and inorganic calcite UWC-1, we find approach 2, following the B-11/Ca-interference relationship, gives the best mean accuracies (within 0.4 parts per thousand of solution values) and external reproducibilities (+/- 0.5 parts per thousand 2 SD for PS69/3181). This approach has been applied to analyses of an annual growth cycle of a Siderastrea siderea coral and eight Cibicidoides wuellerstorfi benthic foraminifera. Both coral and foraminifera data match solution MC-ICP-MS analyses within reported uncertainties. Conclusions LA-MC-ICP-MS can produce accurate and precise delta B-11 data to a 0.5 parts per thousand (2 sigma) level on <0.3 ng B after correction for Ca interference effects.
引用
收藏
页码:959 / 968
页数:10
相关论文
共 50 条
  • [41] Application of a "Continuous-Acquisition-Method" to potassium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Gu, Hai-Ou
    Sun, He
    Huang, Chao
    Wang, Fangyue
    Ge, Can
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (13)
  • [42] Intra- and inter-tooth variation in strontium isotope ratios from prehistoric seals by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Glykou, A.
    Eriksson, G.
    Stora, J.
    Schmitt, M.
    Kooijman, E.
    Liden, K.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (15) : 1215 - 1224
  • [43] Precise and accurate Ga isotope ratio measurements of geological samples by multi-collector inductively coupled plasma mass spectrometry
    Yuxu Zhang
    Pan Qiao
    Chuanwei Zhu
    Haifeng Fan
    Hanjie Wen
    Acta Geochimica, 2024, 43 (06) : 1054 - 1064
  • [44] Hafnium isotope analysis of mixed standard solutions by multi-collector inductively coupled plasma mass spectrometry: an evaluation of isobaric interference corrections
    Choi M.S.
    Cheong C.-S.
    Kim J.
    Shin H.S.
    Journal of Analytical Science and Technology, 4 (1)
  • [45] Comparison of factors affecting the accuracy of high-precision magnesium isotope analysis by multi-collector inductively coupled plasma mass spectrometry
    Teng, Fang-Zhen
    Yang, Wei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (01) : 19 - 24
  • [46] Matrix effects on the multi-collector inductively coupled plasma mass spectrometric analysis of high-precision cadmium and zinc isotope ratios
    Shiel, Alyssa E.
    Barling, Jane
    Orians, Kristin J.
    Weis, Dominique
    ANALYTICA CHIMICA ACTA, 2009, 633 (01) : 29 - 37
  • [47] Determination of Stable Silicon Isotopes Using Multi-Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang An-Yu
    Zhang Jing
    Zhang Rui-Feng
    Xue Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (09) : 1353 - 1358
  • [48] Recent advances in method development and application of multi-collector inductively coupled plasma mass spectrometry
    Zhang Luyao
    Chen Zigu
    Yang Xuezhi
    Lu Dawei
    Liu Qian
    Jiang Guibin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (01) : 4 - 9
  • [49] Development of an indigenous multi-collector inductively coupled plasma mass spectrometer
    Yogesh Kumar
    R. K. Bhatia
    E. Ravisankar
    Prakash Abichandani
    T. K. Saha
    V. Nataraju
    R. K. Vatsa
    Indian Journal of Physics, 2024, 98 : 2559 - 2570
  • [50] Precise analysis of potassium isotopic composition in plant materials by multi-collector inductively coupled plasma mass spectrometry
    He, Mao-Yong
    Ren, Tong Xiang
    Jin, Zhang Dong
    Deng, Li
    Liu, Hai Jiao
    Cheng, Yuan Yuan
    Li, Zheng Yan
    Liu, Xing Xing
    Yang, Yang
    Chang, Hong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 209