The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:26
|
作者
Standish, Christopher D. [1 ]
Chalk, Thomas B. [1 ]
Babila, Tali L. [1 ]
Milton, J. Andy [1 ]
Palmer, Martin R. [1 ]
Foster, Gavin L. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr Southampton, Sch Ocean & Earth Sci, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
关键词
PH; RATIOS; CARBONATES; ACCURATE; CORALS;
D O I
10.1002/rcm.8432
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Boron isotope analysis of marine carbonates by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) offers the potential for rapid sample throughput, and the means to examine micron-scale variations in the delta B-11 signatures of fossil skeletons and shells/tests of marine organisms. Existing studies demonstrate an acceptable level of reproducibility is achievable, but also typically show a level of accuracy outside the limits required by most applications. Here we investigate matrix interference effects as a cause of inaccuracy and imprecision. Methods Analyses were performed on a standard format Thermo Scientific Neptune Plus MC-ICP mass spectrometer coupled to a New Wave Research 193 nm ArF laser ablation system. The effects of matrix interference on delta B-11 analysis were investigated through analyses of a set of reference materials with differing B/Ca ratios. Three approaches to correct for matrix-induced effects were trialled: (1) use of matrix-matched standards, (2) utilisation of the relationship between delta B-11 inaccuracy and(11)B/Ca-43, B-11/(ArCa4+)-Ar-40 or B-11/Ca-interference from three reference materials with known delta B-11 values and varying B/Ca ratios, and (3) direct characterisation of the (sloping) interference itself. Results Matrix interference from scattered Ca ions on B-10 can impede both the accuracy and the reproducibility of delta B-11 analysis by LA-MC-ICP-MS. Based on analyses of two in-house reference materials, deep sea coral PS69/3181 and inorganic calcite UWC-1, we find approach 2, following the B-11/Ca-interference relationship, gives the best mean accuracies (within 0.4 parts per thousand of solution values) and external reproducibilities (+/- 0.5 parts per thousand 2 SD for PS69/3181). This approach has been applied to analyses of an annual growth cycle of a Siderastrea siderea coral and eight Cibicidoides wuellerstorfi benthic foraminifera. Both coral and foraminifera data match solution MC-ICP-MS analyses within reported uncertainties. Conclusions LA-MC-ICP-MS can produce accurate and precise delta B-11 data to a 0.5 parts per thousand (2 sigma) level on <0.3 ng B after correction for Ca interference effects.
引用
收藏
页码:959 / 968
页数:10
相关论文
共 50 条
  • [21] Lead isotope ratios in lead-glazed ceramics determined by laser ablation multi-collector inductively coupled plasma mass spectrometry for discriminating purpose
    Zong, Chunlei
    Bao, Zhian
    Ran, Wangli
    Ling, Xue
    Chen, Lu
    Chen, Kaiyun
    Yuan, Honglin
    ANALYTICAL METHODS, 2018, 10 (21) : 2456 - 2463
  • [22] A critical review of isotopic fractionation and interference correction methods for isotope ratio measurements by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Zhang, Wen
    Hu, Zhaochu
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 171
  • [23] An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry
    Barling, Jane
    Weis, Dominique
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (04) : 653 - 662
  • [24] Development of a Matrix-Matched Barite Reference Material (NWU-Brt) for Calibration of In Situ S Isotope Measurements by Laser Ablation Multi-Collector Inductively Coupled Plasma-Mass Spectrometry
    Lv, Nan
    Bao, Zhian
    Nie, Xiaojuan
    Chen, Kaiyun
    Zhang, Yan
    Yuan, Honglin
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (02) : 411 - 421
  • [25] Characterization of Four Copper Materials for Application as Reference Materials for High Precision Copper Isotope Analysis by Laser Ablation Inductively Coupled Plasma Multi-Collector Mass Spectrometry
    Yang, Zhaoping
    Jackson, Simon Edward
    Skulski, Thomas
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [26] Investigation of nitrogen addition, position effect and mismatch intensity effect in Li isotopic analysis by nanosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Lin, Jie
    Liu, Yongsheng
    Zhu, Luyun
    Zhang, Wen
    Hu, Zhaochu
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 177
  • [27] Matrix-independent boron isotope analysis of silicate and carbonate reference materials by ultraviolet femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry with application to the cold-water coral Desmophyllum dianthus
    Steinhoefel, Grit
    Beck, Kristina K. K.
    Benthien, Albert
    Richter, Klaus-Uwe
    Schmidt-Grieb, Gertraud M. M.
    Bijma, Jelle
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (13) : e9508
  • [28] Hf isotope ratio analysis using multi-collector inductively coupled plasma mass spectrometry: an evaluation of isobaric interference corrections
    Chu, NC
    Taylor, RN
    Chavagnac, V
    Nesbitt, RW
    Boella, RM
    Milton, JA
    German, CR
    Bayon, G
    Burton, K
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (12) : 1567 - 1574
  • [29] Measurement of isotopic ratios of uranium by multi-collector inductively coupled plasma mass spectrometry
    Li, Li-Li
    Li, Jin-Ying
    Zhao, Yong-Gang
    Liu, Jun-Ling
    Zhang, Ji-Long
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2006, 28 (03): : 152 - 156
  • [30] Laser Ablation Inductively Coupled Mass Spectrometry for in situ Trace Element and Isotope Analysis
    Ash, R. D.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 538 - 539