The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:26
|
作者
Standish, Christopher D. [1 ]
Chalk, Thomas B. [1 ]
Babila, Tali L. [1 ]
Milton, J. Andy [1 ]
Palmer, Martin R. [1 ]
Foster, Gavin L. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr Southampton, Sch Ocean & Earth Sci, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
关键词
PH; RATIOS; CARBONATES; ACCURATE; CORALS;
D O I
10.1002/rcm.8432
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Boron isotope analysis of marine carbonates by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) offers the potential for rapid sample throughput, and the means to examine micron-scale variations in the delta B-11 signatures of fossil skeletons and shells/tests of marine organisms. Existing studies demonstrate an acceptable level of reproducibility is achievable, but also typically show a level of accuracy outside the limits required by most applications. Here we investigate matrix interference effects as a cause of inaccuracy and imprecision. Methods Analyses were performed on a standard format Thermo Scientific Neptune Plus MC-ICP mass spectrometer coupled to a New Wave Research 193 nm ArF laser ablation system. The effects of matrix interference on delta B-11 analysis were investigated through analyses of a set of reference materials with differing B/Ca ratios. Three approaches to correct for matrix-induced effects were trialled: (1) use of matrix-matched standards, (2) utilisation of the relationship between delta B-11 inaccuracy and(11)B/Ca-43, B-11/(ArCa4+)-Ar-40 or B-11/Ca-interference from three reference materials with known delta B-11 values and varying B/Ca ratios, and (3) direct characterisation of the (sloping) interference itself. Results Matrix interference from scattered Ca ions on B-10 can impede both the accuracy and the reproducibility of delta B-11 analysis by LA-MC-ICP-MS. Based on analyses of two in-house reference materials, deep sea coral PS69/3181 and inorganic calcite UWC-1, we find approach 2, following the B-11/Ca-interference relationship, gives the best mean accuracies (within 0.4 parts per thousand of solution values) and external reproducibilities (+/- 0.5 parts per thousand 2 SD for PS69/3181). This approach has been applied to analyses of an annual growth cycle of a Siderastrea siderea coral and eight Cibicidoides wuellerstorfi benthic foraminifera. Both coral and foraminifera data match solution MC-ICP-MS analyses within reported uncertainties. Conclusions LA-MC-ICP-MS can produce accurate and precise delta B-11 data to a 0.5 parts per thousand (2 sigma) level on <0.3 ng B after correction for Ca interference effects.
引用
收藏
页码:959 / 968
页数:10
相关论文
共 50 条
  • [11] High precision in-situ Pb isotopic analysis of sulfide minerals by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    HongLin Yuan
    Cong Yin
    Xu Liu
    KaiYun Chen
    ZhiAn Bao
    ChunLei Zong
    MenNing Dai
    ShaoCong Lai
    Rong Wang
    ShaoYong Jiang
    Science China Earth Sciences, 2015, 58 : 1713 - 1721
  • [12] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Mai Takagi
    Jun Yoshinaga
    Atsushi Tanaka
    Haruhiko Seyama
    Analytical Sciences, 2011, 27 : 29 - 35
  • [13] Determination of lead isotope ratios in Mn-Fe-rich nodules by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Bao, Zhian
    Zong, Chunlei
    Chen, Lu
    Lei, Danbo
    Chen, Kaiyun
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (12) : 2143 - 2152
  • [14] Zirconium isotopic composition of zircon reference materials by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Xie, Jin-Cheng
    Zhu, Di-Cheng
    Wang, Qing
    Zhang, Liang-Liang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2023, 484
  • [15] Non-matrix-matched determination of lead isotope ratios in ancient bronze artifacts by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Bao Zhian
    Yuan Wenting
    Yuan Honglin
    Liu Xu
    Chen Kaiyun
    Zong Chunlei
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 402 : 12 - 19
  • [16] Influence of room temperature on magnesium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Zhang, Xing-Chao
    Zhang, An-Yu
    Zhang, Zhao-Feng
    Huang, Fang
    Yu, Hui-Min
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (13) : 1026 - 1030
  • [17] Isotope fractionation during ion beam formation in multi-collector inductively coupled plasma mass spectrometry
    Kivel, Niko
    Guenther-Leopold, Ines
    Vanhaecke, Frank
    Guenther, Detlef
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 126 - 132
  • [18] Assessment of matrix effects associated with Fe isotope analysis using 266 nm femtosecond and 193 nm nanosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Zheng, Xin-Yuan
    Beard, Brian L.
    Johnson, Clark M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (01) : 68 - 83
  • [19] Precise determination of rhenium isotope composition by multi-collector inductively-coupled plasma mass spectrometry
    Miller, Christian A.
    Peucker-Ehrenbrink, Bernhard
    Ball, Lary
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (08) : 1069 - 1078