The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:26
|
作者
Standish, Christopher D. [1 ]
Chalk, Thomas B. [1 ]
Babila, Tali L. [1 ]
Milton, J. Andy [1 ]
Palmer, Martin R. [1 ]
Foster, Gavin L. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr Southampton, Sch Ocean & Earth Sci, Waterfront Campus,European Way, Southampton SO14 3ZH, Hants, England
关键词
PH; RATIOS; CARBONATES; ACCURATE; CORALS;
D O I
10.1002/rcm.8432
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Boron isotope analysis of marine carbonates by laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) offers the potential for rapid sample throughput, and the means to examine micron-scale variations in the delta B-11 signatures of fossil skeletons and shells/tests of marine organisms. Existing studies demonstrate an acceptable level of reproducibility is achievable, but also typically show a level of accuracy outside the limits required by most applications. Here we investigate matrix interference effects as a cause of inaccuracy and imprecision. Methods Analyses were performed on a standard format Thermo Scientific Neptune Plus MC-ICP mass spectrometer coupled to a New Wave Research 193 nm ArF laser ablation system. The effects of matrix interference on delta B-11 analysis were investigated through analyses of a set of reference materials with differing B/Ca ratios. Three approaches to correct for matrix-induced effects were trialled: (1) use of matrix-matched standards, (2) utilisation of the relationship between delta B-11 inaccuracy and(11)B/Ca-43, B-11/(ArCa4+)-Ar-40 or B-11/Ca-interference from three reference materials with known delta B-11 values and varying B/Ca ratios, and (3) direct characterisation of the (sloping) interference itself. Results Matrix interference from scattered Ca ions on B-10 can impede both the accuracy and the reproducibility of delta B-11 analysis by LA-MC-ICP-MS. Based on analyses of two in-house reference materials, deep sea coral PS69/3181 and inorganic calcite UWC-1, we find approach 2, following the B-11/Ca-interference relationship, gives the best mean accuracies (within 0.4 parts per thousand of solution values) and external reproducibilities (+/- 0.5 parts per thousand 2 SD for PS69/3181). This approach has been applied to analyses of an annual growth cycle of a Siderastrea siderea coral and eight Cibicidoides wuellerstorfi benthic foraminifera. Both coral and foraminifera data match solution MC-ICP-MS analyses within reported uncertainties. Conclusions LA-MC-ICP-MS can produce accurate and precise delta B-11 data to a 0.5 parts per thousand (2 sigma) level on <0.3 ng B after correction for Ca interference effects.
引用
收藏
页码:959 / 968
页数:10
相关论文
共 50 条
  • [1] Strontium isotope analysis in prehistoric cod otoliths by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Glykou, Aikaterini
    Ritchie, Kenneth
    Hargrave, Matthew S.
    Visch, Wouter
    Liden, Kerstin
    JOURNAL OF ARCHAEOLOGICAL SCIENCE-REPORTS, 2021, 37
  • [2] Enhanced sensitivity in laser ablation multi-collector inductively coupled plasma mass spectrometry
    Cottle, John M.
    Burrows, Andrew J.
    Kylander-Clark, Andrew
    Freedman, Philip A.
    Cohen, Roy S.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (11) : 1700 - 1706
  • [3] In situ calcium isotope analysis of Sr-rich carbonates using laser ablation multi-collector inductively coupled plasma mass spectrometry
    Jiang, Jiao
    Chen, Wei
    Lu, Jue
    Liu, Yonghong
    Li, Ming
    Sun, Jian
    Zhao, Kuidong
    Jiang, Shaoyong
    Liu, Yongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (04)
  • [4] In situ Analysis of Mg Isotopic Compositions of Basalt Glasses by Femtosecond Laser Ablation Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Dai Meng-Ning
    Bao Zhi-An
    Chen Kai-Yun
    Yuan Hong-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (02) : 173 - 177
  • [5] Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Varga, Z.
    Krachler, M.
    Nicholl, A.
    Ernstberger, M.
    Wiss, T.
    Wallenius, M.
    Mayer, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1076 - 1080
  • [6] Analysis of In situ Pb Isotope in Sulfides by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang Wen
    Hu Zhao-Chu
    Jin Zhen-Min
    Liu Yong-Sheng
    Ling Wen-Li
    Hu Qing-Hai
    Fu Jia-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 14 - 22
  • [7] In situ Mg isotope measurements of biogenic carbonates using laser ablation multi-collector inductively coupled plasma mass spectrometry: A new tool to understand biomineralisation
    Sadekov, Aleksey
    Lloyd, Nicholas S.
    Misra, Sambuddha
    D'Olivo, Juan Pablo
    McCulloch, Malcolm
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [8] High precision in-situ Pb isotopic analysis of sulfide minerals by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Yuan HongLin
    Yin Cong
    Liu Xu
    Chen KaiYun
    Bao Zhian
    Zong ChunLei
    Dai MenNing
    Lai ShaoCong
    Wang Rong
    Jiang ShaoYong
    SCIENCE CHINA-EARTH SCIENCES, 2015, 58 (10) : 1713 - 1721
  • [9] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Takagi, Mai
    Yoshinaga, Jun
    Tanaka, Atsushi
    Seyama, Haruhiko
    ANALYTICAL SCIENCES, 2011, 27 (01) : 29 - 35
  • [10] High precision in-situ Pb isotopic analysis of sulfide minerals by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    YUAN HongLin
    YIN Cong
    LIU Xu
    CHEN KaiYun
    BAO ZhiAn
    ZONG ChunLei
    DAI MenNing
    LAI ShaoCong
    WANG Rong
    JIANG ShaoYong
    Science China(Earth Sciences), 2015, 58 (10) : 1713 - 1721