Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI

被引:11
|
作者
Lee, Hyunyeol [1 ]
Zhao, Xia [1 ]
Song, Hee Kwon [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Lab Struct Physiol & Funct Imaging LSPFI, Dept Radiol, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
Ultrashort echo time (UTE); skull MRI; motion correction; self-navigation; k-space trajectory correction; MAGNETIC-RESONANCE; RECONSTRUCTION; OPTIMIZATION; REGISTRATION; STRATEGY; IMAGES; ROBUST; MYELIN;
D O I
10.1109/TMI.2020.2978405
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrashort echo time (UTE) MRI is capable of detecting signals from protons with very short T-2 relaxation times, and thus has potential for skull-selective imaging as a radiation-free alternative to computed tomography. However, relatively long scan times make the technique vulnerable to artifacts from involuntary subject motion. Here, we developed a self-navigated, three-dimensional (3D) UTE pulse sequence, which builds on dual-RF, dual-echo UTE imaging, and a retrospective motion correction scheme for motion-resistant skull MRI. Full echo signals in the second readout serve as a self-navigator that yields a time-course of center of mass, allowing for adaptive determination of motion states. Furthermore, golden-means based k-space trajectory was employed to achieve a quasi-uniform distribution of sampling views on a spherical k-space surface for any subset of the entire data collected, thereby allowing reconstruction of low-resolution images pertaining to each motion state for subsequent estimation of rigid-motion parameters. Finally, the extracted trajectory of the head was used to make the whole k-space datasets motion-consistent, leading to motion-corrected, high-resolution images. Additionally, we posit that hardware-related k-space trajectory errors, if uncorrected, result in obscured bone contrast. Thus, a calibration scan was performed once to measure k-space encoding locations, subsequently used during image reconstruction of actual imaging data. In vivo studies were performed to evaluate the effectiveness of the proposed correction schemes in combination with approaches to accelerated bone-selective imaging. Results illustrating effective removal of motion artifacts and clear depiction of skull bone voxels suggest that the proposed method is robust to intermittent head motions during scanning.
引用
收藏
页码:2869 / 2880
页数:12
相关论文
共 50 条
  • [31] Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    Rahmer, J
    Börnert, P
    Groen, J
    Bos, C
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) : 1075 - 1082
  • [32] Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines
    Bannas, Peter
    Bell, Laura C.
    Johnson, Kevin M.
    Schiebler, Mark L.
    Francois, Christopher J.
    Motosugi, Utaroh
    Consigny, Daniel
    Reeder, Scott B.
    Nagle, Scott K.
    RADIOLOGY, 2016, 278 (02) : 413 - 421
  • [33] Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study
    Yan Sun
    Yujie Chen
    Xuesheng Li
    Yi Liao
    Xijian Chen
    Yu Song
    Xinyue Liang
    Yongming Dai
    Dapeng Chen
    Gang Ning
    BMC Medical Imaging, 23
  • [34] Optimized three-dimensional ultrashort echo time: Magnetic resonance fingerprinting for myelin tissue fraction mapping
    Zhou, Zihan
    Li, Qing
    Liao, Congyu
    Cao, Xiaozhi
    Liang, Hui
    Chen, Quan
    Pu, Run
    Ye, Huihui
    Tong, Qiqi
    He, Hongjian
    Zhong, Jianhui
    HUMAN BRAIN MAPPING, 2023, 44 (06) : 2209 - 2223
  • [35] Assessment of lung density in pediatric patients using three-dimensional ultrashort echo-time and four-dimensional zero echo-time sequences
    Konstantinos G. Zeimpekis
    Christian J. Kellenberger
    Julia Geiger
    Japanese Journal of Radiology, 2022, 40 : 722 - 729
  • [36] Assessment of lung density in pediatric patients using three-dimensional ultrashort echo-time and four-dimensional zero echo-time sequences
    Zeimpekis, Konstantinos G.
    Kellenberger, Christian J.
    Geiger, Julia
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (07) : 722 - 729
  • [37] Fast Three-Dimensional Dual Echo Dixon Technique Improves Fat Suppression in Breast MRI
    Le-Petross, Huong
    Kundra, Vikas
    Szklaruk, Janio
    Wei, Wei
    Hortobagyi, Gabriel N.
    Ma, Jingfei
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 889 - 894
  • [38] Accelerated Motion Corrected Three-Dimensional Abdominal MRI Using Total Variation Regularized SENSE Reconstruction
    Cruz, Gastao
    Atkinson, David
    Buerger, Christian
    Schaeffter, Tobias
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1484 - 1498
  • [39] Evaluation of pulmonary ventilation in COVID-19 patients using oxygen-enhanced three-dimensional ultrashort echo time MRI: a preliminary study
    Zhao, F.
    Zheng, L.
    Shan, F.
    Dai, Y.
    Shen, J.
    Yang, S.
    Shi, Y.
    Xue, K.
    Zhang, Z.
    CLINICAL RADIOLOGY, 2021, 76 (05) : 391.e33 - 391.e41
  • [40] Fat-suppressed three-dimensional dual echo dixon technique for contrast agent enhanced MRI
    Ma, J
    Vu, AT
    Son, JB
    Choi, H
    Hazle, JD
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (01) : 36 - 41