Evaluation of pulmonary ventilation in COVID-19 patients using oxygen-enhanced three-dimensional ultrashort echo time MRI: a preliminary study

被引:7
|
作者
Zhao, F. [1 ,2 ]
Zheng, L. [3 ]
Shan, F. [1 ]
Dai, Y. [3 ]
Shen, J. [1 ]
Yang, S. [1 ]
Shi, Y. [1 ]
Xue, K. [3 ]
Zhang, Z. [1 ,4 ]
机构
[1] Fudan Univ, Shanghai Publ Hlth Clin Ctr, Dept Radiol, Shanghai 201508, Peoples R China
[2] Xiamen Univ, Affiliated Hosp 1, Dept Radiol, Xiamen, Peoples R China
[3] United Imaging Healthcare, Cent Res Inst, MR Collaborat, Shanghai 201800, Peoples R China
[4] Fudan Univ, Dept Principals Off, Shanghai 200433, Peoples R China
关键词
MAGNETIC-RESONANCE; COMPUTED-TOMOGRAPHY; CHEST CT; LUNG; PNEUMONIA; DISEASE; ASTHMA;
D O I
10.1016/j.crad.2021.02.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the lung function of coronavirus disease 2019 (COVID-19) patients using oxygen-enhanced (OE) ultrashort echo time (UTE) MRI. MATERIALS AND METHODS: Forty-nine patients with COVID-19 were included in the study. The OE-MRI was based on a respiratory-gated three-dimensional (3D) radial UTE sequence. For each patient, the percent signal enhancement (PSE) map was calculated using the expression PSE = (S-100% - S-21%)/S-21%, where S-21% and S-100% are signals acquired during room air and 100% oxygen inhalation, respectively. Agreement of lesion detectability between UTE-MRI and computed tomography (CT) was performed using the kappa test. The Mann-Whitney U-test was used to evaluate the difference in the mean PSE between mild-type COVID-19 and common-type COVID-19. Spearman's test was used to assess the relationship between lesion mean PSE and lesion size. Furthermore, the Manne-Whitney U-test was used to evaluate the difference in region of interest (ROI) mean PSE between normal pulmonary parenchyma and lesions. The Kruskal-Wallis test was applied to test the difference in the mean PSE between different lesion types. RESULTS: CT and UTE-MRI reached good agreement in lesion detectability. Ventilation measures in mild-type patients (5.3 +/- 5.5%) were significantly different from those in common-type patients (3 +/- 3.9%). Besides, there was no significant correlation between lesion mean PSE and lesion size. The mean PSE of COVID-19 lesions (3.2 +/- 4.9%) was significantly lower than that of the pulmonary parenchyma (5.4 +/- 3.9%). No significant difference was found among different lesion types. CONCLUSION: OE-UTE-MRI could serve as a promising method for the assessment of lung function or treatment management of COVID-19 patients. (C) 2021 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:391.e33 / 391.e41
页数:9
相关论文
共 36 条
  • [1] Pulmonary ventilation imaging in asthma and cystic fibrosis using oxygen-enhanced 3D radial ultrashort echo time MRI
    Zha, Wei
    Kruger, Stanley J.
    Johnson, Kevin M.
    Cadman, Robert V.
    Bell, Laura C.
    Liu, Fang
    Hahn, Andrew D.
    Evans, Michael D.
    Nagle, Scott K.
    Fain, Sean B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (05) : 1287 - 1297
  • [2] Pulmonary Ventilation Imaging in Asthma and Cystic Fibrosis Using Oxygen-Enhanced 3D Radial Ultrashort Echo Time MRI
    Zha, W.
    Kruger, S. J.
    Cadman, R. V.
    Hahn, A.
    Nagle, S. K.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [3] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Ji Young Ha
    Kyeong Hwa Ryu
    Ho Cheol Kim
    European Radiology, 2019, 29 : 2253 - 2262
  • [4] Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Ha, Ji Young
    Ryu, Kyeong Hwa
    Kim, Ho Cheol
    EUROPEAN RADIOLOGY, 2019, 29 (05) : 2253 - 2262
  • [5] Viability of Oxygen-enhanced Ventilation Imaging of the Lungs Using Ultra-short Echo Time MRI
    Sasaki, Tomoaki
    Takahashi, Koji
    Obara, Makoto
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 259 - 261
  • [6] Evaluation of gadolinium deposition in cortical bone using three-dimensional ultrashort echo time quantitative susceptibility mapping: A preliminary study
    Zhang, Xiaodong
    Zhou, Beibei
    Chen, Yanjun
    Cai, Zhenyu
    Guo, Yihao
    Wei, Zhao
    Li, Shisi
    Feng, Yanqiu
    Sedaghat, Sam
    Jang, Hyungseok
    NMR IN BIOMEDICINE, 2024, 37 (01)
  • [7] Assessment of lung deformation in patients with idiopathic pulmonary fibrosis with elastic registration technique on pulmonary three-dimensional ultrashort echo time MRI
    Xiaoyan Yang
    Pengxin Yu
    Haishuang Sun
    Mei Deng
    Anqi Liu
    Chen Li
    Wenyan Meng
    Wenxiu Xu
    Bingbing Xie
    Jing Geng
    Yanhong Ren
    Rongguo Zhang
    Min Liu
    Huaping Dai
    Insights into Imaging, 15
  • [8] Assessment of lung deformation in patients with idiopathic pulmonary fibrosis with elastic registration technique on pulmonary three-dimensional ultrashort echo time MRI
    Yang, Xiaoyan
    Yu, Pengxin
    Sun, Haishuang
    Deng, Mei
    Liu, Anqi
    Li, Chen
    Meng, Wenyan
    Xu, Wenxiu
    Xie, Bingbing
    Geng, Jing
    Ren, Yanhong
    Zhang, Rongguo
    Liu, Min
    Dai, Huaping
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [9] Three-Dimensional Pulmonary Perfusion MRI with Radial Ultrashort Echo Time and Spatial-Temporal Constrained Reconstruction
    Bauman, Grzegorz
    Johnson, Kevin M.
    Bell, Laura C.
    Velikina, Julia V.
    Samsonov, Alexey A.
    Nagle, Scott K.
    Fain, Sean B.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 555 - 564
  • [10] Three-dimensional Ultrashort Echo Time MRI: A More Sensitive Tool for Monitoring Patients with Cystic Fibrosis
    Iwasawa, Tae
    RADIOLOGY, 2023, 308 (01)