Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI

被引:11
|
作者
Lee, Hyunyeol [1 ]
Zhao, Xia [1 ]
Song, Hee Kwon [1 ]
Wehrli, Felix W. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Lab Struct Physiol & Funct Imaging LSPFI, Dept Radiol, Philadelphia, PA 19104 USA
基金
美国国家卫生研究院;
关键词
Ultrashort echo time (UTE); skull MRI; motion correction; self-navigation; k-space trajectory correction; MAGNETIC-RESONANCE; RECONSTRUCTION; OPTIMIZATION; REGISTRATION; STRATEGY; IMAGES; ROBUST; MYELIN;
D O I
10.1109/TMI.2020.2978405
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrashort echo time (UTE) MRI is capable of detecting signals from protons with very short T-2 relaxation times, and thus has potential for skull-selective imaging as a radiation-free alternative to computed tomography. However, relatively long scan times make the technique vulnerable to artifacts from involuntary subject motion. Here, we developed a self-navigated, three-dimensional (3D) UTE pulse sequence, which builds on dual-RF, dual-echo UTE imaging, and a retrospective motion correction scheme for motion-resistant skull MRI. Full echo signals in the second readout serve as a self-navigator that yields a time-course of center of mass, allowing for adaptive determination of motion states. Furthermore, golden-means based k-space trajectory was employed to achieve a quasi-uniform distribution of sampling views on a spherical k-space surface for any subset of the entire data collected, thereby allowing reconstruction of low-resolution images pertaining to each motion state for subsequent estimation of rigid-motion parameters. Finally, the extracted trajectory of the head was used to make the whole k-space datasets motion-consistent, leading to motion-corrected, high-resolution images. Additionally, we posit that hardware-related k-space trajectory errors, if uncorrected, result in obscured bone contrast. Thus, a calibration scan was performed once to measure k-space encoding locations, subsequently used during image reconstruction of actual imaging data. In vivo studies were performed to evaluate the effectiveness of the proposed correction schemes in combination with approaches to accelerated bone-selective imaging. Results illustrating effective removal of motion artifacts and clear depiction of skull bone voxels suggest that the proposed method is robust to intermittent head motions during scanning.
引用
收藏
页码:2869 / 2880
页数:12
相关论文
共 50 条
  • [41] Evaluation of a new motion correction algorithm in PET/CT: combining the entire acquired PET data to create a single three-dimensional motion-corrected PET/CT image
    Minamimoto, Ryogo
    Mitsumoto, Takuya
    Miyata, Yoko
    Sunaoka, Fumio
    Morooka, Miyako
    Okasaki, Momoko
    Iagaru, Andrei
    Kubota, Kazuo
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (02) : 162 - 170
  • [42] Motion compensated self supervised deep learning for highly accelerated 3D ultrashort Echo time pulmonary MRI
    Miller, Zachary
    Johnson, Kevin M.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2361 - 2375
  • [43] Three-dimensional liver motion tracking using real-time two-dimensional MRI
    Brix, Lau
    Ringgaard, Steffen
    Sorensen, Thomas Sangild
    Poulsen, Per Rugaard
    MEDICAL PHYSICS, 2014, 41 (04)
  • [44] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Konstantinos G. Zeimpekis
    Julia Geiger
    Florian Wiesinger
    Gaspar Delso
    Christian J. Kellenberger
    Pediatric Radiology, 2021, 51 : 57 - 65
  • [45] Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging
    Ren, Cui
    Zhu, Qiao
    Li, Qing
    Sommer, Stefan
    Zhang, Xianchang
    Yuan, Huishu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4141 - 4154
  • [46] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Zeimpekis, Konstantinos G.
    Geiger, Julia
    Wiesinger, Florian
    Delso, Gaspar
    Kellenberger, Christian J.
    PEDIATRIC RADIOLOGY, 2021, 51 (01) : 57 - 65
  • [47] Three-dimensional ultrashort echo time (3D UTE) MRI of Achilles tendon at 4.7T MRI with comparison to conventional sequences in an experimental murine model of spondyloarthropathy
    Dallaudiere, Benjamin
    Trotier, A.
    Ribot, E.
    Verdier, D.
    Lepreux, S.
    Miraux, S.
    Hauger, O.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (01) : 127 - 135
  • [48] Three-dimensional visualisation of the fetal heart using prenatal MRI with motion-corrected slice-volume registration: a prospective, single-centre cohort study (vol 393, pg 1619, 2019)
    Lloyd, D. F. A.
    Pushparajah, K.
    Simpson, J. M.
    LANCET, 2022, 399 (10339): : 1940 - 1940
  • [49] Three-dimensional visualisation of the fetal heart using prenatal MRI with motion-corrected slice-volume registration: a prospective, single-centre cohort study (vol 393, pg 1619, 2019)
    Lloyd, D. F. A.
    Pushparajah, K.
    Simpson, J. M.
    LANCET, 2022, 399 (10335): : 1606 - 1606
  • [50] Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
    Joong Kim, Dae
    Hwang, Kun
    Kim, Hun
    Cha, Jang Gyu
    Jang, Hyungseok
    Park, Ju-Yong
    Kim, Yeo Ju
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (05) : 782 - 791