Quantitative Analysis of Contrast to Noise Ratio Using a Phase Contrast X-ray Imaging Prototype

被引:0
|
作者
Ghani, Muhammad U. [1 ]
Wu, Di [1 ]
Li, Yuhua [1 ]
Kang, Minhua [1 ]
Chen, Wei R.
Wu, Xizeng
Liu, Hong [1 ]
机构
[1] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
来源
关键词
Contrast to Noise Ratio; Phase Contrast; RADIOGRAPHY; RESOLUTION;
D O I
10.1117/12.2001525
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The purpose of this study was to determine the Contrast to Noise Ratio (CNR) of the x-ray images taken with the phase contrast imaging mode and compare them with the CNR of the images taken under the conventional mode. For each mode, three images were taken under three exposure conditions of 100 kVp (2.8mAs), 120 kVp (1.9mAs) and 140kVp (1.42mAs). A 1.61cm thick contrast detail phantom was used as an imaging object. For phase contrast, the source to image detector distance (SID) was 182.88 cm and the source to object (SOD) distance was 73.15 cm. The SOD was the same as SID in the conventional imaging mode. A computed radiography (CR) plate was used as a detector and the output CR images were converted to linear form in relation with the incident x-ray exposure. To calculate CNR, an image processing software was used to determine the mean pixel value and the standard deviation of the pixels in the region of interest (ROI) and in the nearby background around ROI. At any given exposure condition investigated in this study, the CNR values for the phase contrast images were better as compared to the corresponding conventional mode images. The superior image quality in terms of CNR is contributed by the phase-shifts resulted contrast, as well as the reduced scatters due to the air gap between the object and the detector.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Radiographic Techniques, Contrast, and Noise in X-Ray Imaging
    Huda, Walter
    Abrahams, R. Brad
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) : W126 - W131
  • [32] Contrast enhancement of propagation based X-ray phase contrast imaging
    Pan, Adam
    Xu, Ling
    Petruccelli, Jon C.
    Gupta, Rajiv
    Barbastathis, George
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS III, 2014, 9209
  • [33] Preliminary feasibility study of an in-line phase contrast X-ray imaging prototype
    Zhang, Da
    Donovan, Molly
    Fajardo, Laurie L.
    Archer, Ann
    Wu, Xizeng
    Liu, Hong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (09) : 2249 - 2257
  • [34] Noise in x-ray grating-based phase-contrast imaging
    Weber, Thomas
    Bartl, Peter
    Bayer, Florian
    Durst, Juergen
    Haas, Wilhelm
    Michel, Thilo
    Ritter, Andre
    Anton, Gisela
    MEDICAL PHYSICS, 2011, 38 (07) : 4133 - 4140
  • [35] Noise propagation in x-ray phase-contrast imaging and computed tomography
    Nesterets, Yakov I.
    Gureyev, Timur E.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2014, 47 (10)
  • [36] A quantitative, non-interferometric X-ray phase contrast imaging technique
    Munro, Peter R. T.
    Rigon, Luigi
    Ignatyev, Konstantin
    Lopez, Frances C. M.
    Dreossi, Diego
    Speller, Robert D.
    Olivo, Alessandro
    OPTICS EXPRESS, 2013, 21 (01): : 647 - 661
  • [37] Quantitative amplitude and phase contrast imaging in a scanning transmission X-ray microscope
    Hornberger, Benjamin
    Feser, Michael
    Jacobsen, Chris
    ULTRAMICROSCOPY, 2007, 107 (08) : 644 - 655
  • [38] Acoustic radiation pressure: A "phase contrast" agent for x-ray phase contrast imaging
    Bailat, CJ
    Hamilton, TJ
    Rose-Petruck, C
    Diebold, GJ
    APPLIED PHYSICS LETTERS, 2004, 85 (19) : 4517 - 4519
  • [39] An integral phase contrast modulation transfer function for X-ray phase contrast imaging
    Wu, Jie
    Chen, Jiabi
    OPTIK, 2013, 124 (17): : 2583 - 2586
  • [40] USING X-RAY PHASE CONTRAST IMAGING TO IDENTIFY OESOPHAGEAL PATHOLOGY
    Wolfson, Paul
    Jiang, Jinxing
    Wilson, Ash
    Massimi, Lorenzo
    Novelli, Marco
    Lovat, Laurence
    Olivo, Sandro
    GUT, 2019, 68 : A134 - A134