Quantitative Analysis of Contrast to Noise Ratio Using a Phase Contrast X-ray Imaging Prototype

被引:0
|
作者
Ghani, Muhammad U. [1 ]
Wu, Di [1 ]
Li, Yuhua [1 ]
Kang, Minhua [1 ]
Chen, Wei R.
Wu, Xizeng
Liu, Hong [1 ]
机构
[1] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
来源
关键词
Contrast to Noise Ratio; Phase Contrast; RADIOGRAPHY; RESOLUTION;
D O I
10.1117/12.2001525
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The purpose of this study was to determine the Contrast to Noise Ratio (CNR) of the x-ray images taken with the phase contrast imaging mode and compare them with the CNR of the images taken under the conventional mode. For each mode, three images were taken under three exposure conditions of 100 kVp (2.8mAs), 120 kVp (1.9mAs) and 140kVp (1.42mAs). A 1.61cm thick contrast detail phantom was used as an imaging object. For phase contrast, the source to image detector distance (SID) was 182.88 cm and the source to object (SOD) distance was 73.15 cm. The SOD was the same as SID in the conventional imaging mode. A computed radiography (CR) plate was used as a detector and the output CR images were converted to linear form in relation with the incident x-ray exposure. To calculate CNR, an image processing software was used to determine the mean pixel value and the standard deviation of the pixels in the region of interest (ROI) and in the nearby background around ROI. At any given exposure condition investigated in this study, the CNR values for the phase contrast images were better as compared to the corresponding conventional mode images. The superior image quality in terms of CNR is contributed by the phase-shifts resulted contrast, as well as the reduced scatters due to the air gap between the object and the detector.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Quantitative X-ray phase contrast waveguide imaging of bacterial endospores
    Wilke, R. N.
    Hoppert, M.
    Krenkel, M.
    Bartels, M.
    Salditt, T.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2015, 48 : 464 - 476
  • [22] Quantitative X-ray phase contrast waveguide imaging of bacterial endospores
    Wilke, R.N.
    Hoppert, M.
    Krenkel, M.
    Bartels, M.
    Salditt, T.
    Journal of Applied Crystallography, 2015, 48 : 464 - 476
  • [23] Influence of imaging geometry on noise texture in quantitative in-line X-ray phase-contrast imaging
    Chou, Cheng-Ying
    Anastasio, Mark A.
    OPTICS EXPRESS, 2009, 17 (17): : 14466 - 14480
  • [24] Dynamic imaging of the lungs using x-ray phase contrast
    Lewis, RA
    Yagi, N
    Kitchen, MJ
    Morgan, MJ
    Paganin, D
    Siu, KKW
    Pavlov, K
    Williams, I
    Uesugi, K
    Wallace, MJ
    Hall, CJ
    Whitley, J
    Hooper, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21): : 5031 - 5040
  • [25] Elemental x-ray imaging using Zernike phase contrast
    Shao, Qi-Gang
    Chen, Jian
    Wali, Faiz
    Bao, Yuan
    Wang, Zhi-Li
    Zhu, Pei-Ping
    Tian, Yang-Chao
    Gao, Kun
    CHINESE PHYSICS B, 2016, 25 (10)
  • [26] Analysis of X-ray phase contrast imaging in atomizing sprays
    Mark Linne
    Experiments in Fluids, 2012, 52 : 1201 - 1218
  • [27] X-ray phase contrast imaging at MAMI
    M. El-Ghazaly
    H. Backe
    W. Lauth
    G. Kube
    P. Kunz
    A. Sharafutdinov
    T. Weber
    The European Physical Journal A - Hadrons and Nuclei, 2006, 28 : 197 - 208
  • [28] X-ray phase contrast imaging at MAMI
    El-Ghazaly, M.
    Backe, H.
    Lauth, W.
    Kube, G.
    Kunz, P.
    Sharafutdinov, A.
    Weber, T.
    EUROPEAN PHYSICAL JOURNAL A, 2006, 28 (Suppl 1): : 197 - 208
  • [29] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [30] Analysis of X-ray phase contrast imaging in atomizing sprays
    Linne, Mark