Bioimpedance Measurement of Knee Injuries Using Bipolar Electrode Configuration

被引:6
|
作者
Ye, Xuanjie [1 ]
Wu, Lexi [2 ]
Mao, Kaining [1 ]
Feng, Yiwei [1 ]
Li, Jiajun [1 ]
Ning, Lei [3 ]
Chen, Jie [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[2] Zhejiang Univ, Sch Med, Hangzhou 310030, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Orthopaed Surg, Med Coll, Hangzhou 310058, Zhejiang, Peoples R China
关键词
Bioimpedance; Electrodes; Injuries; Knee; Current measurement; Biomedical measurement; Impedance; bipolar electrode configuration; knee injuries; machine learning; portable device; BIOELECTRICAL-IMPEDANCE; ELECTRICAL BIOIMPEDANCE; DRY ELECTRODES; EDEMA; BODY; INFLAMMATION; LYMPHEDEMA; MANAGEMENT; DIAGNOSIS; SEVERITY;
D O I
10.1109/TBCAS.2022.3200355
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Currently, there is no suitable solution for the point-of-care diagnosis of knee injuries. A potential portable and low-cost technique for accessing and monitoring knee injuries is bioimpedance measurement. This study validated the feasibility of the bipolar electrode configuration for knee bioimpedance measurement with two electrodes placed on a fixed pair of knee acupuncture locations called Xiyan. Then, the study collected 76 valid samples to investigate the relationship between bioimpedance and knee injuries, among whom 39 patients have unilateral knee injuries, and 37 individuals have healthy knees. The self-contrast results indicated that knee injuries caused a reduction of bioimpedance of the knee by about 5% on average, which was detectable at around 100 kHz (p approximate to 0.001). Furthermore, the results analyzed by principal component analysis and support vector machines show that the detection sensitivity can reach 87.18% using the leave-one-out cross-validation. We also proposed a low-cost and portable bioimpedance measurement device that meets the needs for measuring knee joint bioimpedance.
引用
收藏
页码:962 / 971
页数:10
相关论文
共 50 条
  • [31] An uniform DBD plasma excited by bipolar nanosecond pulse using wire-cylinder electrode configuration in atmospheric air
    Jiang, Peng-Chao
    Wang, Wen-Chun
    Zhang, Shuai
    Jia, Li
    Yang, De-Zheng
    Tang, Kai
    Liu, Zhi-Jie
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2014, 122 : 107 - 112
  • [32] Comparison of the efficacy of unipolar and bipolar electrode configuration during subthalamic deep brain stimulation
    Deli, Gabriella
    Balas, Istvan
    Nagy, Ferenc
    Balazs, Eva
    Janszky, Jozsef
    Komoly, Samuel
    Kovacs, Norbert
    PARKINSONISM & RELATED DISORDERS, 2011, 17 (01) : 50 - 54
  • [33] Cell constant studies of bipolar and tetrapolar electrode systems for impedance measurement
    Ma, Hanbin
    Su, Yang
    Nathan, Arokia
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1264 - 1270
  • [34] USING THE THREE-FREQUENCY BIOIMPEDANCE MEASUREMENT FOR INHOMOGENEOUS BIOLOGICAL OBJECTS
    Timoshenko, G. V.
    VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA, 2013, (54): : 144 - 150
  • [35] MODIFICATION OF A LEFT-SIDED ACCESSORY ATRIOVENTRICULAR PATHWAY BY RADIOFREQUENCY CURRENT USING A BIPOLAR EPICARDIAL-ENDOCARDIAL ELECTRODE CONFIGURATION
    KUCK, KH
    KUNZE, KP
    GEIGER, MSM
    JACKMAN, WM
    NACCARELLI, GV
    EUROPEAN HEART JOURNAL, 1988, 9 (08) : 927 - 932
  • [36] Modeling in the bioimpedance measurement techniques using general-purpose software
    Paavle, Toivo
    2006 INTERNATIONAL BALTIC ELECTRONICS CONFERENCE, PROCEEDINGS, 2006, : 209 - 212
  • [37] Module Design of a Measurement of Cardiac Output using the Method of Bioimpedance Detection
    Suen Diaz, J. E.
    Martinez, A. B.
    Garcia, M. J.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 710 - 713
  • [38] Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis
    Zhu, F
    Sarkar, S
    Kaitwatcharachai, C
    Greenwood, R
    Ronco, C
    Levin, NW
    BLOOD PURIFICATION, 2003, 21 (01) : 131 - 136
  • [39] Analysis, Simulation, and Development of a Low-Cost Fully Active-Electrode Bioimpedance Measurement Module
    Dimas, Christos
    Alimisis, Vassilis
    Georgakopoulos, Ioannis
    Voudoukis, Nikolaos
    Uzunoglu, Nikolaos
    Sotiriadis, Paul P.
    TECHNOLOGIES, 2021, 9 (03)
  • [40] Chemical Imaging Using a Closed Bipolar Electrode Array
    Iwama, Tomoki
    Inoue, Kumi Y.
    Abe, Hiroya
    Matsue, Tomokazu
    CHEMISTRY LETTERS, 2018, 47 (07) : 843 - 845